{"title":"Modification of rapid human immunodeficiency virus (HIV) antibody assay protocols for detecting recent HIV seroconversion.","authors":"Stephen D Soroka, Timothy C Granade, Debra Candal, Bharat S Parekh","doi":"10.1128/CDLI.12.8.918-921.2005","DOIUrl":null,"url":null,"abstract":"<p><p>Assay protocols of three rapid human immunodeficiency virus (HIV) assays, OraQuick-1/2, SeroStrip-1/2, and Determine-1/2, were modified to detect recent HIV seroconversion using a higher dilution of serum specimens. Optimal predilution of specimens resulted in negative test results during early periods of seroconversion (about 6 months), when antibody levels were low. A total of 269 seropositive specimens from routine HIV type 1 testing and from commercial sources (low-titer and seroconversion panels) were tested, and results were recorded as negative (score=0) or positive using intensity scores from 0.5 (weak positive) to 4 (strongly positive). The same specimens were previously tested by a less sensitive (LS) enzyme immunoassay (EIA), Abbott 3A 11-LS, and were classified as recent or long-term infections based on the standardized optical density (SOD) cutoff of 0.75. Overall concordance of >94% was observed between 3A 11-LS and modified rapid tests (RT-LSs) for detecting and distinguishing recent HIV seroconversion from long-term HIV infection (kappa statistics=0.894 to 0.901). Moreover, intensity scores on RT-LSs correlated well with median 3A 11-LS SOD values (R(2)>0.98). Our results indicate that rapid HIV tests can be modified to detect recent seroconversion with results comparable to those from less sensitive EIA.</p>","PeriodicalId":72602,"journal":{"name":"Clinical and diagnostic laboratory immunology","volume":"12 8","pages":"918-21"},"PeriodicalIF":0.0000,"publicationDate":"2005-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1128/CDLI.12.8.918-921.2005","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and diagnostic laboratory immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1128/CDLI.12.8.918-921.2005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32
Abstract
Assay protocols of three rapid human immunodeficiency virus (HIV) assays, OraQuick-1/2, SeroStrip-1/2, and Determine-1/2, were modified to detect recent HIV seroconversion using a higher dilution of serum specimens. Optimal predilution of specimens resulted in negative test results during early periods of seroconversion (about 6 months), when antibody levels were low. A total of 269 seropositive specimens from routine HIV type 1 testing and from commercial sources (low-titer and seroconversion panels) were tested, and results were recorded as negative (score=0) or positive using intensity scores from 0.5 (weak positive) to 4 (strongly positive). The same specimens were previously tested by a less sensitive (LS) enzyme immunoassay (EIA), Abbott 3A 11-LS, and were classified as recent or long-term infections based on the standardized optical density (SOD) cutoff of 0.75. Overall concordance of >94% was observed between 3A 11-LS and modified rapid tests (RT-LSs) for detecting and distinguishing recent HIV seroconversion from long-term HIV infection (kappa statistics=0.894 to 0.901). Moreover, intensity scores on RT-LSs correlated well with median 3A 11-LS SOD values (R(2)>0.98). Our results indicate that rapid HIV tests can be modified to detect recent seroconversion with results comparable to those from less sensitive EIA.