{"title":"High back booster seats: in the field and in the laboratory.","authors":"Julie Brown, Lynne Bilston","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>High back booster (HBB) seat use was studied in the field and in the laboratory. This paper presents details of a case series of 19 children using HBBs in real world crashes. More than half were using HBBs when a forward facing restraint would have been more suitable (i.e. inappropriately), and incorrect use was identified in 3 cases. All serious injury occurred in children inappropriately or incorrectly using HBBs. Laboratory simulations modelled on real world cases demonstrate a greater injury potential in misused HBBs than in correctly used HBBs due to excessive upper body excursion.</p>","PeriodicalId":80490,"journal":{"name":"Annual proceedings. Association for the Advancement of Automotive Medicine","volume":"50 ","pages":"365-79"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3217468/pdf/aam50_p345.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual proceedings. Association for the Advancement of Automotive Medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
High back booster (HBB) seat use was studied in the field and in the laboratory. This paper presents details of a case series of 19 children using HBBs in real world crashes. More than half were using HBBs when a forward facing restraint would have been more suitable (i.e. inappropriately), and incorrect use was identified in 3 cases. All serious injury occurred in children inappropriately or incorrectly using HBBs. Laboratory simulations modelled on real world cases demonstrate a greater injury potential in misused HBBs than in correctly used HBBs due to excessive upper body excursion.