{"title":"Subcutaneous open-loop insulin delivery for type 1 diabetes: Paradigm Real-Time System.","authors":"S L Pohar","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>(1) An open-loop insulin delivery system combines an external insulin pump with continuous monitoring of glucose levels via a subcutaneous sensor. The sensor communicates glucose readings to the pump using a radio transmitter. (2) In four small, comparative studies, adults and children with poorly controlled type 1 diabetes who were randomized to use the Paradigm Real-Time System had clinically important improvements in A1c (a measure of average glycemic control over the previous three months) compared to baseline. (3) Some studies found greater improvements in A1c and less hypoglycemia with the Paradigm Real-Time System compared to multiple daily insulin injections or pump therapy combined with conventional glucometer readings. (4) Adverse events with the Paradigm Real- Time System include infection, itching, irritation, and redness at the site of the glucose sensor, and rare instances of insulin pump malfunction. (5) Based on the limited amount of research published to date, the impact of the Paradigm Real-Time System on long-term glycemic control, prevention of diabetic complications, or quality of life is unclear.</p>","PeriodicalId":83756,"journal":{"name":"Issues in emerging health technologies","volume":" 105","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Issues in emerging health technologies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

(1) An open-loop insulin delivery system combines an external insulin pump with continuous monitoring of glucose levels via a subcutaneous sensor. The sensor communicates glucose readings to the pump using a radio transmitter. (2) In four small, comparative studies, adults and children with poorly controlled type 1 diabetes who were randomized to use the Paradigm Real-Time System had clinically important improvements in A1c (a measure of average glycemic control over the previous three months) compared to baseline. (3) Some studies found greater improvements in A1c and less hypoglycemia with the Paradigm Real-Time System compared to multiple daily insulin injections or pump therapy combined with conventional glucometer readings. (4) Adverse events with the Paradigm Real- Time System include infection, itching, irritation, and redness at the site of the glucose sensor, and rare instances of insulin pump malfunction. (5) Based on the limited amount of research published to date, the impact of the Paradigm Real-Time System on long-term glycemic control, prevention of diabetic complications, or quality of life is unclear.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
1型糖尿病皮下开环胰岛素输送:范式实时系统。
(1)一种开环胰岛素输送系统结合了外部胰岛素泵和通过皮下传感器连续监测葡萄糖水平。传感器通过无线电发射器将葡萄糖读数传递给泵。(2)在四项小型比较研究中,随机选择使用Paradigm实时系统的1型糖尿病控制不佳的成人和儿童患者,与基线相比,A1c(衡量前三个月平均血糖控制的指标)有重要的临床改善。(3)一些研究发现,与每日多次胰岛素注射或泵治疗结合常规血糖仪读数相比,Paradigm实时系统的A1c改善更大,低血糖发生率更低。(4) Paradigm实时系统的不良事件包括葡萄糖传感器部位的感染、瘙痒、刺激和发红,以及罕见的胰岛素泵故障。(5)基于迄今发表的有限研究,Paradigm实时系统对长期血糖控制、糖尿病并发症预防或生活质量的影响尚不清楚。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Laparoscopic diaphragm pacing for tetraplegia. Milnacipran for fibromyalgia. Continuous erythropoietin receptor activator (Mircera) for renal anemia. Rotigotine transdermal patches (Neupro) for the treatment of Parkinson's disease. Implantable hemodynamic monitoring (the Chronicle IHM system): remote telemonitoring for patients with heart failure.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1