Plates with angular stability: our personal experience in surgical treatment of fractures of the proximal extremity of the humerus.

La Chirurgia degli organi di movimento Pub Date : 2008-02-01 Epub Date: 2008-03-03 DOI:10.1007/s12306-007-0017-0
Rosario Lupo, Santo Alberto Rapisarda, Salvatore Lauria, Giovanni Palmisciano
{"title":"Plates with angular stability: our personal experience in surgical treatment of fractures of the proximal extremity of the humerus.","authors":"Rosario Lupo,&nbsp;Santo Alberto Rapisarda,&nbsp;Salvatore Lauria,&nbsp;Giovanni Palmisciano","doi":"10.1007/s12306-007-0017-0","DOIUrl":null,"url":null,"abstract":"<p><p>We here report our experience in the use of locking proximal humerus plates that, compared to the old-generation ones, have shown a reduced incidence of complications, more manageability and higher preservation of soft tissues. Thirty-two patients underwent surgical treatment with plates with angular stability: 20 women and 12 men, with an average age of 52 years; in 6 cases they were fractures with 2 fragments, in 20 cases they were with 3 fragments and in 6 cases with 4 fragments. Results, evaluated according to the Constant Score, with a minimum follow-up of 6 months and the longest of 2 years, have revealed a 79-point Constant Score one year after surgery (min 42, max 94). In 2 cases we have observed necrosis of the epiphysis while there have not been any cases of secondary mobilisation of the synthesis equipment. Our findings, if we consider the low necrosis percentage, show the good adaptability and the preservation of the soft tissues as guaranteed by the synthesis equipment and by the surgery performed.</p>","PeriodicalId":76085,"journal":{"name":"La Chirurgia degli organi di movimento","volume":"91 2","pages":"97-101"},"PeriodicalIF":0.0000,"publicationDate":"2008-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s12306-007-0017-0","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"La Chirurgia degli organi di movimento","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12306-007-0017-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2008/3/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

We here report our experience in the use of locking proximal humerus plates that, compared to the old-generation ones, have shown a reduced incidence of complications, more manageability and higher preservation of soft tissues. Thirty-two patients underwent surgical treatment with plates with angular stability: 20 women and 12 men, with an average age of 52 years; in 6 cases they were fractures with 2 fragments, in 20 cases they were with 3 fragments and in 6 cases with 4 fragments. Results, evaluated according to the Constant Score, with a minimum follow-up of 6 months and the longest of 2 years, have revealed a 79-point Constant Score one year after surgery (min 42, max 94). In 2 cases we have observed necrosis of the epiphysis while there have not been any cases of secondary mobilisation of the synthesis equipment. Our findings, if we consider the low necrosis percentage, show the good adaptability and the preservation of the soft tissues as guaranteed by the synthesis equipment and by the surgery performed.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
角度稳定钢板:我们在肱骨近端骨折手术治疗中的个人经验。
我们在此报告我们使用锁定肱骨近端钢板的经验,与老一代的钢板相比,其并发症发生率降低,更易管理,并能更好地保存软组织。32例患者行角度稳定钢板手术治疗:女性20例,男性12例,平均年龄52岁;2块骨折6例,3块骨折20例,4块骨折6例。结果,根据Constant Score进行评估,最小随访6个月,最长随访2年,术后1年的Constant Score为79分(最小42分,最大94分)。在2例中,我们观察到骨骺坏死,而没有任何合成设备二次活动的病例。如果考虑到低坏死率,我们的研究结果表明,合成设备和手术保证了软组织的良好适应性和保存。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Spinal Fusion for Degenerative Disc Disease: An Operation in Search of an Indication Infected nonunions of long bones of the upper extremity: staged reconstruction using polymethylmethacrylate and bone graft impregnated with antibiotics. Distally based venous flap: a new technique for the correction of syndactyly without skin graft in adult patients. Clinical outcome and quality of life after computer-assisted total knee arthroplasty: results from a prospective, single-surgeon study and review of the literature. Long-term results of cementless anatomic total hip replacement in dysplastic hips.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1