{"title":"Comparative study of dose distribution between carbon ion radiotherapy and photon radiotherapy for head and neck tumor.","authors":"M Amirul Islam, Takeshi Yanagi, Jun-Etsu Mizoe, Hideyuki Mizuno, Hirohiko Tsujii","doi":"10.1007/s11604-008-0252-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>A comparative treatment planning study has been performed between carbon ion radiotherapy (CIRT) and photon radiotherapy [three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)] to assess the potential improvements and limitations that could result for locally advanced, nonresectable head and neck tumors.</p><p><strong>Materials and methods: </strong>Seven patients, originally treated with CIRT, were randomly selected for the comparative study. The evaluations analyzed using dose-volume histogram parameters, conformity index, inhomogeneity coefficient, and dose to the organs at risk (OARs).</p><p><strong>Results: </strong>The mean conformity index was 1.46, 1.43, and 1.22 for 3D-CRT, IMRT, and CIRT, respectively. The mean inhomogeneity coefficient was 0.05, 0.07, and 0.02 for 3D-CRT, IMRT, and CIRT respectively. Photon plans resulted in greater volumes of normal tissues at 10% to 95% isodose levels compared with the corresponding carbon ion plans where the volumes increased by a factor of 1.2 to 2.7 for 3D-CRT and 1.2 to 2.0 for IMRT.</p><p><strong>Conclusion: </strong>CIRT has the potential to improve the target dose conformity, inhomogeneity coefficient, and OAR sparing when compared with 3D-CRT and IMRT. Compared with 3D-CRT, normal tissue exposure was reduced mainly in the mid-to low-isodose levels using IMRT. Additional improvement was obtained using CIRT.</p>","PeriodicalId":49640,"journal":{"name":"Radiation medicine","volume":"26 7","pages":"415-21"},"PeriodicalIF":0.0000,"publicationDate":"2008-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s11604-008-0252-9","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11604-008-0252-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2008/9/4 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
Purpose: A comparative treatment planning study has been performed between carbon ion radiotherapy (CIRT) and photon radiotherapy [three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)] to assess the potential improvements and limitations that could result for locally advanced, nonresectable head and neck tumors.
Materials and methods: Seven patients, originally treated with CIRT, were randomly selected for the comparative study. The evaluations analyzed using dose-volume histogram parameters, conformity index, inhomogeneity coefficient, and dose to the organs at risk (OARs).
Results: The mean conformity index was 1.46, 1.43, and 1.22 for 3D-CRT, IMRT, and CIRT, respectively. The mean inhomogeneity coefficient was 0.05, 0.07, and 0.02 for 3D-CRT, IMRT, and CIRT respectively. Photon plans resulted in greater volumes of normal tissues at 10% to 95% isodose levels compared with the corresponding carbon ion plans where the volumes increased by a factor of 1.2 to 2.7 for 3D-CRT and 1.2 to 2.0 for IMRT.
Conclusion: CIRT has the potential to improve the target dose conformity, inhomogeneity coefficient, and OAR sparing when compared with 3D-CRT and IMRT. Compared with 3D-CRT, normal tissue exposure was reduced mainly in the mid-to low-isodose levels using IMRT. Additional improvement was obtained using CIRT.