Uncertainty assessment of polychlorinated dibenzo-p-dioxins and dibenzofuran and dioxin-like polychlorinated biphenyl analysis in stationary source sample emissions in accordance with the impending European standard EN-1948 using fly ashes.
K Martínez, J Rivera-Austrui, M A Adrados, M Abalos, J J Llerena, B van Bavel, J Rivera, E Abad
{"title":"Uncertainty assessment of polychlorinated dibenzo-p-dioxins and dibenzofuran and dioxin-like polychlorinated biphenyl analysis in stationary source sample emissions in accordance with the impending European standard EN-1948 using fly ashes.","authors":"K Martínez, J Rivera-Austrui, M A Adrados, M Abalos, J J Llerena, B van Bavel, J Rivera, E Abad","doi":"10.1016/j.chroma.2009.06.024","DOIUrl":null,"url":null,"abstract":"<p><p>The analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) present in stack gas emissions and solid residues from incinerators will be mandatory in the foreseeable future. European standard EN-1948 is in the process of being updated through the addition of a new Part 4 related to the analysis of the 12 dl-PCBs. Therefore, either a comprehensive and reliable method capable of analyzing all of these 29 compounds (12 dl-PCBs and 17 2,3,7,8-PCDD/Fs) needs to be developed, or the existing PCDD/F analytical procedure must be adapted to include the dl-PCBs. This study has taken the latter approach of modifying PCDD/F methodology and in particular the fractionation step, by isolating dioxins and dl-PCBs into separate fractions ready for high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS) analysis. Results obtained from the analysis of Certified Reference Materials (CRM-490 and CRM-615) and fly ashes from the European Committee for Standardization (CEN) intercalibration study demonstrated that the proposed methodology is appropriate to determine the dl-PCBs in accordance with the impending European standard EN-1948. Uncertainty values obtained during the validation of the analytical methodology were 13% total I-TEQ (International Toxic Equivalent) for PCDD/Fs and 31% total WHO-TEQ (World Health Organization Toxic Equivalent) in the case of dl-PCBs. In addition, 'real' samples such as emissions and fly ashes were successfully analyzed following the proposed analytical method.</p>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":"1216 31","pages":"5888-94"},"PeriodicalIF":3.8000,"publicationDate":"2009-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.chroma.2009.06.024","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.chroma.2009.06.024","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2009/6/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 15
Abstract
The analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) present in stack gas emissions and solid residues from incinerators will be mandatory in the foreseeable future. European standard EN-1948 is in the process of being updated through the addition of a new Part 4 related to the analysis of the 12 dl-PCBs. Therefore, either a comprehensive and reliable method capable of analyzing all of these 29 compounds (12 dl-PCBs and 17 2,3,7,8-PCDD/Fs) needs to be developed, or the existing PCDD/F analytical procedure must be adapted to include the dl-PCBs. This study has taken the latter approach of modifying PCDD/F methodology and in particular the fractionation step, by isolating dioxins and dl-PCBs into separate fractions ready for high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS) analysis. Results obtained from the analysis of Certified Reference Materials (CRM-490 and CRM-615) and fly ashes from the European Committee for Standardization (CEN) intercalibration study demonstrated that the proposed methodology is appropriate to determine the dl-PCBs in accordance with the impending European standard EN-1948. Uncertainty values obtained during the validation of the analytical methodology were 13% total I-TEQ (International Toxic Equivalent) for PCDD/Fs and 31% total WHO-TEQ (World Health Organization Toxic Equivalent) in the case of dl-PCBs. In addition, 'real' samples such as emissions and fly ashes were successfully analyzed following the proposed analytical method.
期刊介绍:
The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.