Patterns of cardiovascular control during repeated tests of orthostatic loading.

Jerry Joseph Batzel, Nandu Goswami, Helmut Karl Lackner, Andreas Roessler, Mostafa Bachar, Franz Kappel, Helmut Hinghofer-Szalkay
{"title":"Patterns of cardiovascular control during repeated tests of orthostatic loading.","authors":"Jerry Joseph Batzel,&nbsp;Nandu Goswami,&nbsp;Helmut Karl Lackner,&nbsp;Andreas Roessler,&nbsp;Mostafa Bachar,&nbsp;Franz Kappel,&nbsp;Helmut Hinghofer-Szalkay","doi":"10.1007/s10558-009-9086-z","DOIUrl":null,"url":null,"abstract":"<p><p>To investigate patterns of cardiovascular control, a protocol of head up tilt (HUT) followed by lower body negative pressure (LBNP), which represents a significant cardiovascular control challenge, was employed. Linear regression of beat-to-beat heart rate (HR) and mean blood pressure (MBP) data collected over repeated tests was used to analyze control response during the LBNP phase of the combined HUT + LBNP protocol. Four runs for each of 10 healthy young males reaching presyncope were analyzed. Subjects were classified into 2 groups based on the consistency of MBP regulation in response to central hypovolemia induced by LBNP. The consistent group tended to exhibit consistent HR slope (rate of change of HR over time as calculated by linear regression) whereas subjects in the inconsistent group could not be easily classified. Subjects with consistent MBP maintenance exhibited patterns suggesting a consistency of response in cardiovascular control whereas subjects less successful in maintaining MBP exhibited less clearly defined patterns over four runs.</p>","PeriodicalId":55275,"journal":{"name":"Cardiovascular Engineering (dordrecht, Netherlands)","volume":"9 4","pages":"134-43"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10558-009-9086-z","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering (dordrecht, Netherlands)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10558-009-9086-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

To investigate patterns of cardiovascular control, a protocol of head up tilt (HUT) followed by lower body negative pressure (LBNP), which represents a significant cardiovascular control challenge, was employed. Linear regression of beat-to-beat heart rate (HR) and mean blood pressure (MBP) data collected over repeated tests was used to analyze control response during the LBNP phase of the combined HUT + LBNP protocol. Four runs for each of 10 healthy young males reaching presyncope were analyzed. Subjects were classified into 2 groups based on the consistency of MBP regulation in response to central hypovolemia induced by LBNP. The consistent group tended to exhibit consistent HR slope (rate of change of HR over time as calculated by linear regression) whereas subjects in the inconsistent group could not be easily classified. Subjects with consistent MBP maintenance exhibited patterns suggesting a consistency of response in cardiovascular control whereas subjects less successful in maintaining MBP exhibited less clearly defined patterns over four runs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在直立负荷的重复试验中心血管控制的模式。
为了研究心血管控制模式,采用了头向上倾斜(HUT)然后下体负压(LBNP)的方案,这代表了心血管控制的重大挑战。通过重复试验收集的搏动心率(HR)和平均血压(MBP)数据进行线性回归,分析HUT + LBNP联合治疗方案LBNP阶段的控制反应。我们分析了10名健康年轻男性出现晕厥前症状时的4次跑步。根据LBNP诱导中枢性低血容量血症时MBP调节的一致性将受试者分为两组。一致组倾向于表现出一致的HR斜率(通过线性回归计算的HR随时间的变化率),而不一致组的受试者不容易分类。持续维持MBP的受试者表现出的模式表明心血管控制反应的一致性,而不太成功维持MBP的受试者在四次试验中表现出不太明确的模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3D Bioprinting of a Tissue Engineered Human Heart Tissue-Mimicking Materials for Cardiac Imaging Phantom—Section 2: From Fabrication to Optimization Square Root Design for Natural Frequency Module of Dynamic ECG Features—a Preliminary Study Tissue-Mimicking Materials for Cardiac Imaging Phantom—Section 1: From Conception to Materials Selection Biopolymers as Potential Carrier for Effervescent Reaction Based Drug Delivery System in Gastrointestinal Condition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1