Alternative option in the treatment of very small ruptured intracranial aneurysms

Ming-Shiang Yang MD , Ho-Fai Wong MD , Tzu-Hsien Yang MD , Yao-Liang Chen MD , Si-Wa Chan MD , Huey-Jen Lee MD , Yung Wei Tung MD , Chung-Wei Tu MD , Tai-Yi Chen MD
{"title":"Alternative option in the treatment of very small ruptured intracranial aneurysms","authors":"Ming-Shiang Yang MD ,&nbsp;Ho-Fai Wong MD ,&nbsp;Tzu-Hsien Yang MD ,&nbsp;Yao-Liang Chen MD ,&nbsp;Si-Wa Chan MD ,&nbsp;Huey-Jen Lee MD ,&nbsp;Yung Wei Tung MD ,&nbsp;Chung-Wei Tu MD ,&nbsp;Tai-Yi Chen MD","doi":"10.1016/j.wneu.2009.09.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To evaluate the safety and protective effect of relative undersized coil with loose coil core in the clinical dilemma condition—very small (43.0 mm) ruptured intracranial aneurysm.</p></div><div><h3>Methods</h3><p>We studied 12 patients (4 men, 8 women) who had suffered from acute ruptured small intracranial aneurysms (2-3 mm in size, with SAH presentation). All subjects underwent a single coil embolization procedure. An undersized coil (equivalent to the neck size or 0.5 mm smaller than the aneurysm diameter) was chosen as the embolizer.</p><p>Based on the postembolization angiogram, subjects were divided into 2 groups. One was labeled as the initial complete obliteration group (NR) and the other as the incomplete obliteration group (SR). Fisher exact test and the Wilcoxon rank sum test were used to for statistical analysis.</p></div><div><h3>Results</h3><p>The technical success rate was 100% without any procedure-related complication. The follow-up interval ranged from 6 to 32 months. No episode of rebleeding or coil migration could be defined in the admissive and following period. Loose coil core were seen in all patients. The total recurrent rate was 8.3% (1/12); only one patient suffered from recurrent lesion in SR group.</p></div><div><h3>Conclusion</h3><p>The preliminary result showed that under-sized coil packing with loose coil core could provide the protective effect and prevent from further rebleeding for very small ruptured aneurysms. It should be considered as an alternative option in the treatment of acute ruptured very small aneurysms when other conventional strategies are not feasible.</p></div>","PeriodicalId":22153,"journal":{"name":"Surgical Neurology","volume":"72 ","pages":"Pages S41-S46"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.wneu.2009.09.003","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Neurology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0090301909008490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Background

To evaluate the safety and protective effect of relative undersized coil with loose coil core in the clinical dilemma condition—very small (43.0 mm) ruptured intracranial aneurysm.

Methods

We studied 12 patients (4 men, 8 women) who had suffered from acute ruptured small intracranial aneurysms (2-3 mm in size, with SAH presentation). All subjects underwent a single coil embolization procedure. An undersized coil (equivalent to the neck size or 0.5 mm smaller than the aneurysm diameter) was chosen as the embolizer.

Based on the postembolization angiogram, subjects were divided into 2 groups. One was labeled as the initial complete obliteration group (NR) and the other as the incomplete obliteration group (SR). Fisher exact test and the Wilcoxon rank sum test were used to for statistical analysis.

Results

The technical success rate was 100% without any procedure-related complication. The follow-up interval ranged from 6 to 32 months. No episode of rebleeding or coil migration could be defined in the admissive and following period. Loose coil core were seen in all patients. The total recurrent rate was 8.3% (1/12); only one patient suffered from recurrent lesion in SR group.

Conclusion

The preliminary result showed that under-sized coil packing with loose coil core could provide the protective effect and prevent from further rebleeding for very small ruptured aneurysms. It should be considered as an alternative option in the treatment of acute ruptured very small aneurysms when other conventional strategies are not feasible.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
治疗极小破裂颅内动脉瘤的另一种选择
背景评价相对小尺寸松芯线圈在临床困境-极小(43.0 mm)颅内动脉瘤破裂情况下的安全性和保护作用。方法我们研究了12例(男4例,女8例)急性破裂的颅内小动脉瘤(2-3 mm大小,伴有SAH表现)。所有受试者均行单线圈栓塞术。选择一个较小的线圈(相当于颈部大小或小于动脉瘤直径0.5毫米)作为栓塞剂。根据栓塞后血管造影,将受试者分为两组。一组标记为初始完全闭塞组(NR),另一组标记为不完全闭塞组(SR)。采用Fisher精确检验和Wilcoxon秩和检验进行统计分析。结果手术成功率100%,无手术并发症发生。随访时间为6 ~ 32个月。在入院和随访期间没有再出血或线圈移动的发生。所有患者均见线圈芯松动。总复发率为8.3% (1/12);SR组仅有1例复发。结论初步结果表明,对于极小的破裂动脉瘤,采用小尺寸线圈填料和松散线圈芯可以起到保护作用,防止再出血。当其他常规治疗方法不可行时,应考虑将其作为治疗急性破裂的极小动脉瘤的另一种选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Surgical Neurology
Surgical Neurology 医学-临床神经学
自引率
0.00%
发文量
0
期刊最新文献
Cardiac ventricular myosin and slow skeletal myosin exhibit dissimilar chemomechanical properties despite bearing the same myosin heavy chain isoform. Moyamoya disease. PNIPAAM modified mesoporous hydroxyapatite for sustained osteogenic drug release and promoting cell attachment. Biomedical research Editorial Board
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1