Abdelkarime K Jahrome, Imo Hoefer, Frans L Moll, Graeme J Houston, Peter A Stonebridge, Peter J Blankestijn, Gert J de Borst
{"title":"An animal paired crossover ePTFE arteriovenous graft model.","authors":"Abdelkarime K Jahrome, Imo Hoefer, Frans L Moll, Graeme J Houston, Peter A Stonebridge, Peter J Blankestijn, Gert J de Borst","doi":"10.1186/1750-1164-4-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Previously, we developed a porcine model for Arterio Venous Graft (AVG) failure to allow assessment of new access strategies. This model was limited concerning graft length. In the present technical report, we describe a modification of our model allowing the assessment of long AVGs.</p><p><strong>Technique: </strong>In 4 pigs, AVGs of 15 cm length were created bilaterally in a cross-over fashion between the carotid artery and the contralateral jugular vein. Two days (2 pigs) and two weeks (2 pigs) after AV shunting, graft patency was evaluated by angiography, showing all four grafts to be patent, with no sign of angiographic or macroscopic narrowing at the anastomoses sites.</p><p><strong>Conclusions: </strong>In this modified pig AVG failure model, implantation of a bilateral cross-over long AVG is a feasible approach. The present model offers a suitable tool to study local interventions or compare various long graft designs aimed at improvement of AVG patency.</p>","PeriodicalId":87428,"journal":{"name":"Annals of surgical innovation and research","volume":"4 ","pages":"7"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1750-1164-4-7","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of surgical innovation and research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1750-1164-4-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Purpose: Previously, we developed a porcine model for Arterio Venous Graft (AVG) failure to allow assessment of new access strategies. This model was limited concerning graft length. In the present technical report, we describe a modification of our model allowing the assessment of long AVGs.
Technique: In 4 pigs, AVGs of 15 cm length were created bilaterally in a cross-over fashion between the carotid artery and the contralateral jugular vein. Two days (2 pigs) and two weeks (2 pigs) after AV shunting, graft patency was evaluated by angiography, showing all four grafts to be patent, with no sign of angiographic or macroscopic narrowing at the anastomoses sites.
Conclusions: In this modified pig AVG failure model, implantation of a bilateral cross-over long AVG is a feasible approach. The present model offers a suitable tool to study local interventions or compare various long graft designs aimed at improvement of AVG patency.