Two-incision versus modified Watson-Jones total hip arthroplasty in the same patients-- a prospective study of clinical outcomes and patient preferences.

Chih-Chien Hu, Jen-Suh Chern, Pang-Hsin Hsieh, Chun-Hsiung Shih, Steve W N Ueng, Mel S Lee
{"title":"Two-incision versus modified Watson-Jones total hip arthroplasty in the same patients-- a prospective study of clinical outcomes and patient preferences.","authors":"Chih-Chien Hu,&nbsp;Jen-Suh Chern,&nbsp;Pang-Hsin Hsieh,&nbsp;Chun-Hsiung Shih,&nbsp;Steve W N Ueng,&nbsp;Mel S Lee","doi":"10.4103/2319-4170.106166","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The two-incision technique and the modified Watson-Jones technique use muscular intervals and avoid muscle cutting in total hip arthroplasty (THA). However these two techniques have not been compared.</p><p><strong>Methods: </strong>A prospective randomized study of clinical outcomes and patient preferences was performed in 20 patients who had a two-incision THA in one hip and a modified Watson-Jones THA in the other between January 2004 and August 2007. The 20 patients were randomized equally to the two-incision first or the modified Watson-Jones first group. After the second surgery, patients were asked about their preferences for one of the two techniques and clinical results were analyzed.</p><p><strong>Results: </strong>After a minimal follow-up of 2 years, there were no differences in the hospital course, clinical results, functional outcomes, and radiographic results between techniques. However more patients (70%) preferred the two-incision side to the modified Watson-Jones side in the first 6 months regardless which procedure was performed first.</p><p><strong>Conclusion: </strong>Given the similarity of these two techniques in cup implantation and with only a difference in femoral stem implantation, we think that the difference in patient preferences in the early postoperative period might be related to the surgical dissection and manipulation of the hip with the modified Watson-Jones technique.</p>","PeriodicalId":10018,"journal":{"name":"Chang Gung medical journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chang Gung medical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/2319-4170.106166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Background: The two-incision technique and the modified Watson-Jones technique use muscular intervals and avoid muscle cutting in total hip arthroplasty (THA). However these two techniques have not been compared.

Methods: A prospective randomized study of clinical outcomes and patient preferences was performed in 20 patients who had a two-incision THA in one hip and a modified Watson-Jones THA in the other between January 2004 and August 2007. The 20 patients were randomized equally to the two-incision first or the modified Watson-Jones first group. After the second surgery, patients were asked about their preferences for one of the two techniques and clinical results were analyzed.

Results: After a minimal follow-up of 2 years, there were no differences in the hospital course, clinical results, functional outcomes, and radiographic results between techniques. However more patients (70%) preferred the two-incision side to the modified Watson-Jones side in the first 6 months regardless which procedure was performed first.

Conclusion: Given the similarity of these two techniques in cup implantation and with only a difference in femoral stem implantation, we think that the difference in patient preferences in the early postoperative period might be related to the surgical dissection and manipulation of the hip with the modified Watson-Jones technique.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
同一患者的双切口与改良沃森-琼斯全髋关节置换术——临床结果和患者偏好的前瞻性研究
背景:双切口技术和改良的Watson-Jones技术在全髋关节置换术中使用肌肉间隔,避免了肌肉切割。然而,这两种技术尚未进行比较。方法:在2004年1月至2007年8月期间,对20例一侧髋关节行双切口THA和另一侧髋关节行改良Watson-Jones THA的患者进行了临床结果和患者偏好的前瞻性随机研究。20例患者平均随机分为双切口先行组和改良沃森-琼斯先行组。在第二次手术后,患者被问及他们对两种技术中的一种的偏好,并分析临床结果。结果:经过最少2年的随访,两种技术在住院过程、临床结果、功能结局和影像学结果方面没有差异。然而,在前6个月,更多的患者(70%)更喜欢双切口侧而不是改良的沃森-琼斯侧,无论先进行哪种手术。结论:考虑到这两种技术在罩杯植入上的相似性,仅在股骨干植入上的差异,我们认为术后早期患者偏好的差异可能与改良Watson-Jones技术对髋关节的手术解剖和操作有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Avian influenza. The diagnosis and treatment of neonatal seizures. Leiomyosarcoma of the adrenal vein. Team innovation climate and knowledge sharing among healthcare managers: mediating effects of altruistic intentions. Serum lipid profile could predict the inception and impacts of violent behaviors among acute psychiatric inpatients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1