Analysis of the compatibility of dental implant systems in fibula free flap reconstruction.

Ramin Carbiner, Waseem Jerjes, Kaveh Shakib, Peter V Giannoudis, Colin Hopper
{"title":"Analysis of the compatibility of dental implant systems in fibula free flap reconstruction.","authors":"Ramin Carbiner,&nbsp;Waseem Jerjes,&nbsp;Kaveh Shakib,&nbsp;Peter V Giannoudis,&nbsp;Colin Hopper","doi":"10.1186/1758-3284-4-37","DOIUrl":null,"url":null,"abstract":"<p><p>As a result of major ablative surgery, head and neck oncology patients can be left with significant defects in the orofacial region. The resultant defect raises the need for advanced reconstruction techniques. The reconstruction in this region is aimed at restoring function and facial contour. The use of vascularised free flaps has revolutionised the reconstruction in the head and neck. Advances in reconstruction techniques have resulted in continuous improvement of oral rehabilitation. For example, endosteal implants are being used to restore the masticatory function by the way of prosthetic replacement of the dentition. Implant rehabilitation usually leads to improved facial appearance, function, restoration of speech and mastication. Suitable dental implant placement's site requires satisfactory width, height and quality of bone. Reconstruction of hard tissue defects therefore will need to be tailored to meet the needs for implant placement.The aim of this feasibility study was to assess the compatibility of five standard commercially available dental implant systems (Biomet 3i, Nobel Biocare, Astra tech, Straumann and Ankylos) for placement into vascularised fibula graft during the reconstruction of oromandibular region.Radiographs (2D) of the lower extremities from 142 patients in the archives of the Department of Radiology in University College London Hospitals (UCLH) were analysed in this study. These radiographs were from 61 females and 81 males. Additionally, 60 unsexed dry fibular bones, 30 right sided, acquired from the collection of the Department of Anatomy, University College London (UCL) were also measured to account for the 3D factor.In the right fibula (dry bone), 90% of the samples measured had a width of 13.1 mm. While in the left fibula (dry bone), 90% of the samples measured had a width of 13.3 mm. Fibulas measured on radiographs had a width of 14.3 mm in 90% of the samples. The length ranges of the dental implants used in this study were: 7-13 mm (Biomet 3i), 10-13 mm (Nobel biocare), 8-13 mm (Astra Tech), 8-12 mm (Straumann ) and 8-11 mm (Ankylos).This study reached a conclusion that the width of fibula is sufficient for placement of most frequently used dental implants for oral rehabilitation after mandibular reconstructive procedures.</p>","PeriodicalId":49195,"journal":{"name":"Head and Neck Optical Diagnostics Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1758-3284-4-37","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Head and Neck Optical Diagnostics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1758-3284-4-37","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

As a result of major ablative surgery, head and neck oncology patients can be left with significant defects in the orofacial region. The resultant defect raises the need for advanced reconstruction techniques. The reconstruction in this region is aimed at restoring function and facial contour. The use of vascularised free flaps has revolutionised the reconstruction in the head and neck. Advances in reconstruction techniques have resulted in continuous improvement of oral rehabilitation. For example, endosteal implants are being used to restore the masticatory function by the way of prosthetic replacement of the dentition. Implant rehabilitation usually leads to improved facial appearance, function, restoration of speech and mastication. Suitable dental implant placement's site requires satisfactory width, height and quality of bone. Reconstruction of hard tissue defects therefore will need to be tailored to meet the needs for implant placement.The aim of this feasibility study was to assess the compatibility of five standard commercially available dental implant systems (Biomet 3i, Nobel Biocare, Astra tech, Straumann and Ankylos) for placement into vascularised fibula graft during the reconstruction of oromandibular region.Radiographs (2D) of the lower extremities from 142 patients in the archives of the Department of Radiology in University College London Hospitals (UCLH) were analysed in this study. These radiographs were from 61 females and 81 males. Additionally, 60 unsexed dry fibular bones, 30 right sided, acquired from the collection of the Department of Anatomy, University College London (UCL) were also measured to account for the 3D factor.In the right fibula (dry bone), 90% of the samples measured had a width of 13.1 mm. While in the left fibula (dry bone), 90% of the samples measured had a width of 13.3 mm. Fibulas measured on radiographs had a width of 14.3 mm in 90% of the samples. The length ranges of the dental implants used in this study were: 7-13 mm (Biomet 3i), 10-13 mm (Nobel biocare), 8-13 mm (Astra Tech), 8-12 mm (Straumann ) and 8-11 mm (Ankylos).This study reached a conclusion that the width of fibula is sufficient for placement of most frequently used dental implants for oral rehabilitation after mandibular reconstructive procedures.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
腓骨游离皮瓣重建中种植体系统的相容性分析。
由于大的消融手术,头颈部肿瘤患者可能会在口面部区域留下明显的缺陷。由此产生的缺陷提高了对先进重建技术的需求。该区域的重建旨在恢复面部功能和轮廓。血管化皮瓣的使用彻底改变了头颈部的重建。口腔重建技术的进步使口腔康复水平不断提高。例如,骨内种植体被用于修复牙列的咀嚼功能。种植体康复通常会改善面部外观,功能,恢复语言和咀嚼功能。合适的植牙位置需要令人满意的骨宽、骨高和骨质量。因此,硬组织缺损的重建将需要量身定制,以满足种植体放置的需要。本可行性研究的目的是评估五种标准的市售牙种植体系统(Biomet 3i, Nobel Biocare, Astra tech, Straumann和Ankylos)在口腔颌下区重建期间植入血管化腓骨移植物的兼容性。本研究分析了伦敦大学学院医院(UCLH)放射科档案中142例患者的下肢x线片(2D)。这些x线片来自61名女性和81名男性。此外,从伦敦大学学院(UCL)解剖学系收集的60块无性别的干腓骨,30块右侧,也被测量以解释三维因素。在右侧腓骨(干骨)中,90%的测量样本宽度为13.1 mm。而在左腓骨(干骨)中,90%的测量样本的宽度为13.3毫米。在90%的样本中,x光片测量的腓骨宽度为14.3毫米。本研究使用的种植体长度范围为:7-13 mm (Biomet 3i)、10-13 mm (Nobel biocare)、8-13 mm (Astra Tech)、8-12 mm (Straumann)和8-11 mm (Ankylos)。本研究得出结论,腓骨的宽度足以放置最常用的种植体,用于下颌骨重建手术后的口腔康复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prevalence and Pattern of Cervical Nodal Metastasis of Upper Aerodigestive Tract Squamous at the Time of Diagnosis in Patients Attending Tikur Anbessa Hospital from September 2015 to September 2020 An Inclusion Epidermoid Cyst, a Rare Complication of Versatile Naso-Labial Flap Immune cell infiltration patterns and survival in head and neck squamous cell carcinoma. Intercondylar distance before and after mandible resection Effect of human beta-defensin-3 on head and neck cancer cell migration using micro-fabricated cell islands.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1