Everolimus-eluting stents: update on current clinical studies.

IF 1.3 Q4 ENGINEERING, BIOMEDICAL Medical Devices-Evidence and Research Pub Date : 2011-01-01 Epub Date: 2011-07-26 DOI:10.2147/MDER.S22043
Dominic J Allocco, Anita A Joshi, Keith D Dawkins
{"title":"Everolimus-eluting stents: update on current clinical studies.","authors":"Dominic J Allocco, Anita A Joshi, Keith D Dawkins","doi":"10.2147/MDER.S22043","DOIUrl":null,"url":null,"abstract":"<p><p>Everolimus-eluting stents (EES) have become the most commonly implanted coronary stents worldwide. This review describes and analyzes the clinical data supporting the use of EES, focusing primarily on published, randomized, controlled trials. Everolimus-eluting stents have been shown to have less restenosis, stent thrombosis, and periprocedural myocardial infarction compared with earlier generation paclitaxel-eluting stents (PES). Lower rates of adverse events for EES compared with PES were generally seen in all subgroups, with the notable exception of patients with diabetes mellitus. There have been fewer, randomized, clinical trials comparing EES with either sirolimus-eluting stents or zotarolimus-eluting stents, although very good results with EES have been observed in the trials that have been performed. Recent clinical trial data suggest that this excellent safety and efficacy profile is maintained in a next-generation EES designed to have improved mechanical properties and radiopacity.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":" ","pages":"91-8"},"PeriodicalIF":1.3000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3417879/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S22043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/7/26 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Everolimus-eluting stents (EES) have become the most commonly implanted coronary stents worldwide. This review describes and analyzes the clinical data supporting the use of EES, focusing primarily on published, randomized, controlled trials. Everolimus-eluting stents have been shown to have less restenosis, stent thrombosis, and periprocedural myocardial infarction compared with earlier generation paclitaxel-eluting stents (PES). Lower rates of adverse events for EES compared with PES were generally seen in all subgroups, with the notable exception of patients with diabetes mellitus. There have been fewer, randomized, clinical trials comparing EES with either sirolimus-eluting stents or zotarolimus-eluting stents, although very good results with EES have been observed in the trials that have been performed. Recent clinical trial data suggest that this excellent safety and efficacy profile is maintained in a next-generation EES designed to have improved mechanical properties and radiopacity.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
依维莫司洗脱支架:当前临床研究的最新进展。
依维莫司洗脱支架(EES)已成为全球最常植入的冠状动脉支架。本综述描述并分析了支持使用 EES 的临床数据,主要侧重于已发表的随机对照试验。与早一代紫杉醇洗脱支架(PES)相比,依维莫司洗脱支架的再狭窄、支架血栓形成和围手术期心肌梗死的发生率较低。与 PES 相比,EES 在所有亚组中的不良事件发生率普遍较低,但糖尿病患者明显例外。将 EES 与西罗莫司洗脱支架或佐他洛利莫司洗脱支架进行比较的随机临床试验较少,但在已进行的试验中观察到 EES 取得了非常好的效果。最近的临床试验数据表明,下一代 EES 在机械性能和放射能力方面都有所改进,因此能保持出色的安全性和疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
期刊最新文献
Mapping Trends and Hotspots Regarding the Use of Lung Ultrasound in the Field of Anesthesiology: A Bibliometric Analysis of Global Research. Evaluation of Healthcare Outcomes of Patients Treated with 3D-Printed-Titanium and PEEK Cages During Fusion Procedures in the Lumbar Spine. Comparison of Ultrasound Energy Delivered to the Anterior Segment Across Different Phacoemulsification Surgical Platforms. Dental Ultrasonography for Visualizing Osteoimmune Conditions and Assessing Jaw Bone Density: A Narrative Review. Noninvasive Detection of Alpha-Amylase in Saliva Using Screen-Printed Carbon Electrodes: A Promising Biomarker for Clinical Oral Diagnostics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1