Single and multiple microphone noise reduction strategies in cochlear implants.

Trends in Amplification Pub Date : 2012-06-01 Epub Date: 2012-08-23 DOI:10.1177/1084713812456906
Kostas Kokkinakis, Behnam Azimi, Yi Hu, David R Friedland
{"title":"Single and multiple microphone noise reduction strategies in cochlear implants.","authors":"Kostas Kokkinakis,&nbsp;Behnam Azimi,&nbsp;Yi Hu,&nbsp;David R Friedland","doi":"10.1177/1084713812456906","DOIUrl":null,"url":null,"abstract":"<p><p>To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow.</p>","PeriodicalId":48972,"journal":{"name":"Trends in Amplification","volume":"16 2","pages":"102-16"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1084713812456906","citationCount":"49","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Amplification","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1084713812456906","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/8/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 49

Abstract

To restore hearing sensation, cochlear implants deliver electrical pulses to the auditory nerve by relying on sophisticated signal processing algorithms that convert acoustic inputs to electrical stimuli. Although individuals fitted with cochlear implants perform well in quiet, in the presence of background noise, the speech intelligibility of cochlear implant listeners is more susceptible to background noise than that of normal hearing listeners. Traditionally, to increase performance in noise, single-microphone noise reduction strategies have been used. More recently, a number of approaches have suggested that speech intelligibility in noise can be improved further by making use of two or more microphones, instead. Processing strategies based on multiple microphones can better exploit the spatial diversity of speech and noise because such strategies rely mostly on spatial information about the relative position of competing sound sources. In this article, we identify and elucidate the most significant theoretical aspects that underpin single- and multi-microphone noise reduction strategies for cochlear implants. More analytically, we focus on strategies of both types that have been shown to be promising for use in current-generation implant devices. We present data from past and more recent studies, and furthermore we outline the direction that future research in the area of noise reduction for cochlear implants could follow.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工耳蜗中单麦克风和多麦克风降噪策略。
为了恢复听觉,人工耳蜗通过复杂的信号处理算法将声音输入转换为电刺激,向听神经传递电脉冲。虽然植入人工耳蜗的人在安静环境中表现良好,但在背景噪音存在的情况下,植入人工耳蜗的人的言语清晰度比正常听力的人更容易受到背景噪音的影响。传统上,为了提高噪声性能,采用了单麦克风降噪策略。最近,一些方法表明,使用两个或更多的麦克风可以进一步提高噪音中的语音清晰度。基于多传声器的处理策略主要依赖于竞争声源相对位置的空间信息,可以更好地利用语音和噪声的空间多样性。在本文中,我们确定并阐明了支持人工耳蜗单麦克风和多麦克风降噪策略的最重要的理论方面。更分析地说,我们关注的是两种类型的策略,这两种策略已被证明有希望在当前一代植入装置中使用。我们介绍了过去和最近的研究数据,并进一步概述了未来在人工耳蜗降噪领域的研究方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Trends in Amplification
Trends in Amplification AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-OTORHINOLARYNGOLOGY
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Laboratory and field study of the potential benefits of pinna cue-preserving hearing aids. Modern prescription theory and application: realistic expectations for speech recognition with hearing AIDS. The perception of telephone-processed speech by combined electric and acoustic stimulation. The master hearing aid. How linguistic closure and verbal working memory relate to speech recognition in noise--a review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1