Artificial muscle for reanimation of the paralyzed face: durability and biocompatibility in a gerbil model.

Levi G Ledgerwood, Steven Tinling, Craig Senders, Annjoe Wong-Foy, Harsha Prahlad, Travis T Tollefson
{"title":"Artificial muscle for reanimation of the paralyzed face: durability and biocompatibility in a gerbil model.","authors":"Levi G Ledgerwood,&nbsp;Steven Tinling,&nbsp;Craig Senders,&nbsp;Annjoe Wong-Foy,&nbsp;Harsha Prahlad,&nbsp;Travis T Tollefson","doi":"10.1001/archfacial.2012.696","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Current management of permanent facial paralysis centers on nerve grafting and muscle transfer; however, limitations of those procedures call for other options.</p><p><strong>Objectives: </strong>To determine the durability and biocompatibility of implanted artificial muscle in a gerbil model and the degree of inflammation and fibrosis at the host tissue-artificial muscle interface.</p><p><strong>Methods: </strong>Electroactive polymer artificial muscle (EPAM) devices engineered in medical-grade silicone were implanted subcutaneously in 13 gerbils. The implanted units were stimulated with 1 kV at 1 Hz, 24 h/d via a function generator. Electrical signal input/output was recorded up to 40 days after implantation. The animals were euthanized between 23 and 65 days after implantation, and the host tissue-implant interface was evaluated histologically.</p><p><strong>Results: </strong>The animals tolerated implantation of the EPAM devices well, with no perioperative deaths. The muscle devices created motion for a mean of 30.3 days (range, 19-40 days), with a mean of 2.6 × 106 cycles (range, 1.6 × 106 to 3.5 × 106 cycles). Histologic examination of the explanted devices revealed the development of a minimal fibrous capsule surrounding the implants, with no evidence of bacterial infection or inflammatory infiltrate. No evidence of device compromise, corrosion, or silicone breakdown was noted.</p><p><strong>Conclusions: </strong>Artificial muscle implanted in this short-term animal model was safe and functional in this preliminary study. We believe that EPAM devices will be a safe and viable option for restoration of facial motions in patients with irreversible facial paralysis.</p>","PeriodicalId":55470,"journal":{"name":"Archives of Facial Plastic Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1001/archfacial.2012.696","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Facial Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1001/archfacial.2012.696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

Background: Current management of permanent facial paralysis centers on nerve grafting and muscle transfer; however, limitations of those procedures call for other options.

Objectives: To determine the durability and biocompatibility of implanted artificial muscle in a gerbil model and the degree of inflammation and fibrosis at the host tissue-artificial muscle interface.

Methods: Electroactive polymer artificial muscle (EPAM) devices engineered in medical-grade silicone were implanted subcutaneously in 13 gerbils. The implanted units were stimulated with 1 kV at 1 Hz, 24 h/d via a function generator. Electrical signal input/output was recorded up to 40 days after implantation. The animals were euthanized between 23 and 65 days after implantation, and the host tissue-implant interface was evaluated histologically.

Results: The animals tolerated implantation of the EPAM devices well, with no perioperative deaths. The muscle devices created motion for a mean of 30.3 days (range, 19-40 days), with a mean of 2.6 × 106 cycles (range, 1.6 × 106 to 3.5 × 106 cycles). Histologic examination of the explanted devices revealed the development of a minimal fibrous capsule surrounding the implants, with no evidence of bacterial infection or inflammatory infiltrate. No evidence of device compromise, corrosion, or silicone breakdown was noted.

Conclusions: Artificial muscle implanted in this short-term animal model was safe and functional in this preliminary study. We believe that EPAM devices will be a safe and viable option for restoration of facial motions in patients with irreversible facial paralysis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于瘫痪面部再生的人造肌肉:沙鼠模型的耐久性和生物相容性。
背景:目前永久性面瘫的治疗主要集中在神经移植和肌肉转移;但是,这些程序的局限性要求有其他选择。目的:测定沙鼠植入人工肌肉的耐久性和生物相容性,以及宿主组织-人工肌肉界面的炎症和纤维化程度。方法:将医用级硅胶材料制成的电活性聚合物人工肌肉(EPAM)装置植入13只沙鼠皮下。通过功能发生器以1 kV、1 Hz、24 h/d的电流刺激植入细胞。记录植入后40天的电信号输入/输出。在植入后23 ~ 65天对动物实施安乐死,对宿主组织-植入物界面进行组织学评价。结果:EPAM植入动物耐受良好,无围手术期死亡。肌肉装置产生运动的平均时间为30.3天(范围19-40天),平均为2.6 × 106个周期(范围1.6 × 106至3.5 × 106个周期)。外植体的组织学检查显示植入物周围有微小的纤维囊,没有细菌感染或炎症浸润的证据。没有证据表明设备损坏,腐蚀或硅胶击穿。结论:该短期动物模型植入人工肌肉是安全的,具有一定的功能性。我们相信,对于不可逆面瘫患者,EPAM装置将是恢复面部运动的一种安全可行的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
2 months
期刊最新文献
A New Model for Facial Nerve Research Outcomes following temporalis tendon transfer in irradiated patients. Ethical considerations in aesthetic rhinoplasty: a survey, critical analysis, and review. Nasal arterial vasculature: medical and surgical applications. Diced cartilage augmentation: early experience with the Tasman technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1