Entrance surface dose of the common radiological investigations in Abuth, Zaria.

Emmanuel Nwokorie, T C Akpa, O P Mallam, Eyo Akpan, P O Ibinaye, O R Obiako, C Nzotta, A C Ugwu
{"title":"Entrance surface dose of the common radiological investigations in Abuth, Zaria.","authors":"Emmanuel Nwokorie,&nbsp;T C Akpa,&nbsp;O P Mallam,&nbsp;Eyo Akpan,&nbsp;P O Ibinaye,&nbsp;O R Obiako,&nbsp;C Nzotta,&nbsp;A C Ugwu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The entrance surface Dose (ESD) was determined among patients who presented for routine radiological examinations using thermoluminescent dosimeter (TLD) chips placed on averagely built adult [(30 cm) chest width, 60-90kg weight and 20-40years)] by multiplying the incident dose/entrances dose by the back scattered factor [BSF] gotten from an experiment. The values obtained from ESD measurements are as follows 8.03 mGy for Abdomen, 0.13 mGy for chest AP, 0.69 mGy for chest lateral, 0.5 mGy for cervical spine; AP: 0.38 mGy for cervical spine lateral; 4.75 mGy for hip AP: 12.83 mGy for hip lateral: 5.74mGy for lumbar spine, AP lumbar spine lateral is 15.15 mGy. 1.38m Gy is for pelvis AP. 2.93mGy for skull AP/PA 1.2mGy for skull lateral, 5.46mGy for thorax AP, while the lateral is 14.90m Gy. The average dose value is 9.28mGy Range 0.13-14.90mGy (Percentage standard error; +/- 1.45). From this studies Radiation doses delivered for routine investigations are generally lower than IAEA reference doses. Using these values for optimization of radiation protection practices for patient should be ensured since it does not rule out options for stochastic radiation.</p>","PeriodicalId":87601,"journal":{"name":"East African journal of public health","volume":"8 3","pages":"205-6"},"PeriodicalIF":0.0000,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"East African journal of public health","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The entrance surface Dose (ESD) was determined among patients who presented for routine radiological examinations using thermoluminescent dosimeter (TLD) chips placed on averagely built adult [(30 cm) chest width, 60-90kg weight and 20-40years)] by multiplying the incident dose/entrances dose by the back scattered factor [BSF] gotten from an experiment. The values obtained from ESD measurements are as follows 8.03 mGy for Abdomen, 0.13 mGy for chest AP, 0.69 mGy for chest lateral, 0.5 mGy for cervical spine; AP: 0.38 mGy for cervical spine lateral; 4.75 mGy for hip AP: 12.83 mGy for hip lateral: 5.74mGy for lumbar spine, AP lumbar spine lateral is 15.15 mGy. 1.38m Gy is for pelvis AP. 2.93mGy for skull AP/PA 1.2mGy for skull lateral, 5.46mGy for thorax AP, while the lateral is 14.90m Gy. The average dose value is 9.28mGy Range 0.13-14.90mGy (Percentage standard error; +/- 1.45). From this studies Radiation doses delivered for routine investigations are generally lower than IAEA reference doses. Using these values for optimization of radiation protection practices for patient should be ensured since it does not rule out options for stochastic radiation.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
扎里亚Abuth常见放射学调查的入口表面剂量。
将热致发光剂量计(TLD)芯片放置在平均体型的成人(胸宽30厘米,体重60-90kg,年龄20-40岁)上进行常规放射检查的患者,通过将入射剂量/进入剂量乘以从实验中得到的后散射因子(BSF)来确定其进入表面剂量(ESD)。ESD测量值为腹部8.03 mGy,胸部AP 0.13 mGy,胸部外侧0.69 mGy,颈椎0.5 mGy;AP:颈椎侧位0.38 mGy;髋关节AP为4.75 mGy,髋关节外侧为12.83 mGy,腰椎为5.74mGy,腰椎外侧AP为15.15 mGy。骨盆AP为1.38m Gy,颅骨AP为2.93mGy /PA,颅骨外侧为1.2mGy,胸腔AP为5.46mGy,外侧为14.90m Gy。平均剂量值为9.28mGy范围0.13-14.90mGy(百分比标准误差;+ / - 1.45)。从这项研究中,为例行调查提供的辐射剂量一般低于原子能机构的参考剂量。应确保使用这些值来优化患者的辐射防护实践,因为它不排除随机辐射的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of the Tanzania programme on task shifting for caesarean sections Health workers perspectives on screening for early detection of diet related risk factors for NCDS during routine health care visits Upper lip Pleomorphic adenoma: Comparison of reported cases from 1990-2011 and literature review IMA Genome-F 7: Draft genome sequences for Ceratocystis fagacearum, C. harringtonii, Grosmannia penicillata, and Huntiella bhutanensis. Assessment of knowledge and attitude towards prevention among faculty members of dental schools of Jammu city
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1