{"title":"Data reduction for cough studies using distribution of audio frequency content.","authors":"Antony Barton,&nbsp;Patrick Gaydecki,&nbsp;Kimberley Holt,&nbsp;Jaclyn A Smith","doi":"10.1186/1745-9974-8-12","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong></p><p><strong>Background: </strong>Recent studies suggest that objectively quantifying coughing in audio recordings offers a novel means to understand coughing and assess treatments. Currently, manual cough counting is the most accurate method for quantifying coughing. However, the demand of manually counting cough records is substantial, demonstrating a need to reduce record lengths prior to counting whilst preserving the coughs within them. This study tested the performance of an algorithm developed for this purpose.</p><p><strong>Methods: </strong>20 subjects were recruited (5 healthy smokers and non-smokers, 5 chronic cough, 5 chronic obstructive pulmonary disease and 5 asthma), fitted with an ambulatory recording system and recorded for 24 hours. The recordings produced were divided into 15 min segments and counted. Periods of inactive audio in each segment were removed using the median frequency and power of the audio signal and the resulting files re-counted.</p><p><strong>Results: </strong>The median resultant segment length was 13.9 s (IQR 56.4 s) and median 24 hr recording length 62.4 min (IQR 100.4). A median of 0.0 coughs/h (IQR 0.0-0.2) were erroneously removed and the variability in the resultant cough counts was comparable to that between manual cough counts. The largest error was seen in asthmatic patients, but still only 1.0% coughs/h were missed.</p><p><strong>Conclusions: </strong>These data show that a system which measures signal activity using the median audio frequency can substantially reduce record lengths without significantly compromising the coughs contained within them.</p>","PeriodicalId":10747,"journal":{"name":"Cough (London, England)","volume":"8 1","pages":"12"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1745-9974-8-12","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cough (London, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1745-9974-8-12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33

Abstract

Unlabelled:

Background: Recent studies suggest that objectively quantifying coughing in audio recordings offers a novel means to understand coughing and assess treatments. Currently, manual cough counting is the most accurate method for quantifying coughing. However, the demand of manually counting cough records is substantial, demonstrating a need to reduce record lengths prior to counting whilst preserving the coughs within them. This study tested the performance of an algorithm developed for this purpose.

Methods: 20 subjects were recruited (5 healthy smokers and non-smokers, 5 chronic cough, 5 chronic obstructive pulmonary disease and 5 asthma), fitted with an ambulatory recording system and recorded for 24 hours. The recordings produced were divided into 15 min segments and counted. Periods of inactive audio in each segment were removed using the median frequency and power of the audio signal and the resulting files re-counted.

Results: The median resultant segment length was 13.9 s (IQR 56.4 s) and median 24 hr recording length 62.4 min (IQR 100.4). A median of 0.0 coughs/h (IQR 0.0-0.2) were erroneously removed and the variability in the resultant cough counts was comparable to that between manual cough counts. The largest error was seen in asthmatic patients, but still only 1.0% coughs/h were missed.

Conclusions: These data show that a system which measures signal activity using the median audio frequency can substantially reduce record lengths without significantly compromising the coughs contained within them.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用音频内容分布的咳嗽研究数据缩减。
背景:最近的研究表明,在录音中客观地量化咳嗽为了解咳嗽和评估治疗提供了一种新的手段。目前,人工咳嗽计数是量化咳嗽最准确的方法。然而,手动计数咳嗽记录的需求很大,这表明需要在计数之前减少记录长度,同时保留其中的咳嗽。本研究测试了为此目的开发的算法的性能。方法:招募20名受试者(健康吸烟者和非吸烟者5名,慢性咳嗽5名,慢性阻塞性肺疾病5名,哮喘5名),配备动态记录系统,记录24小时。所产生的录音被分成15分钟的片段并进行计数。使用音频信号的中位数频率和功率去除每个片段中的非活动音频周期,并重新计算产生的文件。结果:合成片段长度中位数为13.9 s (IQR 56.4 s), 24小时记录长度中位数为62.4 min (IQR 100.4)。中位数为0.0咳嗽/小时(IQR为0.0-0.2)被错误地去除,由此产生的咳嗽计数的变异性与手动咳嗽计数的变异性相当。哮喘患者的误差最大,但仍只有1.0%的咳嗽/h漏诊。结论:这些数据表明,使用中位数音频测量信号活动的系统可以大大缩短记录长度,而不会显著影响其中包含的咳嗽。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A crossover randomized comparative study of zofenopril and ramipril on cough reflex and airway inflammation in healthy volunteers. Standardized method for solubility and storage of capsaicin-based solutions for cough induction. On the definition of chronic cough and current treatment pathways: an international qualitative study. Effect of acid suppression therapy on gastroesophageal reflux and cough in idiopathic pulmonary fibrosis: an intervention study. Severity of cough in idiopathic pulmonary fibrosis is associated with MUC5 B genotype.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1