Monitoring biventricular pacing parameters depending on the left ventricle lead configuration.

Experimental & Clinical Cardiology Pub Date : 2013-01-01
Antonin Prochazka, David Korpas
{"title":"Monitoring biventricular pacing parameters depending on the left ventricle lead configuration.","authors":"Antonin Prochazka,&nbsp;David Korpas","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate whether pacing or sensing configuration has an effect on pacing parameters or their time progression. Three left ventricular (LV) pacing parameters were monitored - the LV pacing threshold, pacing impedance and intrinsic R-wave amplitude.</p><p><strong>Methods: </strong>DATA WERE COLLECTED AT THREE INTERVALS: during implantation; between the second and fifth month after implantation (first follow-up); and between the eighth and 15th month after implantation (second follow-up). Repeated-measures ANOVA was used for the statistical analysis.</p><p><strong>Results: </strong>The impedance, but not its time progression, was significantly higher for the LV tip to LV ring configuration than for other configurations. R-wave amplitude and impedance increased significantly (without dependance on configurations) between implantation and first follow-up, as expected. The time progression of any parameter was not dependent on configuration of the LV lead.</p><p><strong>Conclusions: </strong>LV tip to LV ring is the best configuration for maintaining a high impedance level. It is better to maintain an individual approach for pacing threshold and R-wave amplitude, and their settings.</p>","PeriodicalId":54377,"journal":{"name":"Experimental & Clinical Cardiology","volume":"18 2","pages":"85-8"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718581/pdf/ecc18085.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental & Clinical Cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate whether pacing or sensing configuration has an effect on pacing parameters or their time progression. Three left ventricular (LV) pacing parameters were monitored - the LV pacing threshold, pacing impedance and intrinsic R-wave amplitude.

Methods: DATA WERE COLLECTED AT THREE INTERVALS: during implantation; between the second and fifth month after implantation (first follow-up); and between the eighth and 15th month after implantation (second follow-up). Repeated-measures ANOVA was used for the statistical analysis.

Results: The impedance, but not its time progression, was significantly higher for the LV tip to LV ring configuration than for other configurations. R-wave amplitude and impedance increased significantly (without dependance on configurations) between implantation and first follow-up, as expected. The time progression of any parameter was not dependent on configuration of the LV lead.

Conclusions: LV tip to LV ring is the best configuration for maintaining a high impedance level. It is better to maintain an individual approach for pacing threshold and R-wave amplitude, and their settings.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
监测双心室起搏参数取决于左心室导联配置。
目的:评估起搏或传感配置是否对起搏参数或其时间进程有影响。监测左室起搏阈值、起搏阻抗和固有r波幅值。方法:分三个时间间隔收集数据:植入时;植入后第2 - 5个月(第一次随访);植入后第8 - 15个月(第二次随访)。采用重复测量方差分析进行统计分析。结果:低电压尖端到低电压环构型的阻抗明显高于其他构型,但其时间级数不显著。正如预期的那样,从植入到第一次随访期间,r波振幅和阻抗显著增加(与构型无关)。任何参数的时间进展都不依赖于低压导联的配置。结论:低电压尖端到低电压环是维持高阻抗水平的最佳配置。对于起搏阈值和r波振幅及其设置,最好保持单独的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Experimental & Clinical Cardiology
Experimental & Clinical Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊最新文献
Evidence-performance gap in primary care revisited in patients with diabetes Ischemic postconditioning decreases matrix metalloproteinase-2 expression during ischemia-reperfusion of myocardium in a rabbit model: A preliminary report. The effect of trans-resveratrol on platelet-neutrophil complex formation and neutrophil burst in hypercholesterolemic rats. A modified murine model for the study of reverse cardiac remodelling. Functions of cyclophilin A in atherosclerosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1