Yaser Ghani, Melanie J Coathup, Karin A Hing, Gordon W Blunn
{"title":"Antibacterial effect of incorporating silver ions in electrochemically deposited hydroxyapatite coating: An experimental study.","authors":"Yaser Ghani, Melanie J Coathup, Karin A Hing, Gordon W Blunn","doi":"10.1177/2042533313481212","DOIUrl":null,"url":null,"abstract":"XRD and EDX analyses confirmed the presence of Ag in all coatings deposited using electrochemical method and silver. The mean thickness coating was noted to be highest in EHA/AG group (102.20 4.20 um) followed by PHA (76.40 2.20 um). Mean coating thicknesses in other groups were: PHA/AgNO3 (76.20 1.29 um); EHA (32.98 2.50 um); EHA/ Ag/2-layers (30.70 2.40 um); EHA/AgNO3 (8.60 0.60 um). The average silver content measured was highest with 6.55% in EHA/Ag/2-layer followed by 3.92% in EHA/AgNO3, 0.38% in EHA/Ag and 0.10% in PHA/AgNO3. The electrochemical technique deposited a uniform coating onto the disc surface with clearly defined microcrystals as compared to the PHA-coated discs where the surface appeared smoother. The EHA coating, however, appeared less dense when compared with the PHA coating. DECLARATIONS","PeriodicalId":89182,"journal":{"name":"JRSM short reports","volume":"4 9","pages":"2042533313481212"},"PeriodicalIF":0.0000,"publicationDate":"2013-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/2042533313481212","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JRSM short reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2042533313481212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
XRD and EDX analyses confirmed the presence of Ag in all coatings deposited using electrochemical method and silver. The mean thickness coating was noted to be highest in EHA/AG group (102.20 4.20 um) followed by PHA (76.40 2.20 um). Mean coating thicknesses in other groups were: PHA/AgNO3 (76.20 1.29 um); EHA (32.98 2.50 um); EHA/ Ag/2-layers (30.70 2.40 um); EHA/AgNO3 (8.60 0.60 um). The average silver content measured was highest with 6.55% in EHA/Ag/2-layer followed by 3.92% in EHA/AgNO3, 0.38% in EHA/Ag and 0.10% in PHA/AgNO3. The electrochemical technique deposited a uniform coating onto the disc surface with clearly defined microcrystals as compared to the PHA-coated discs where the surface appeared smoother. The EHA coating, however, appeared less dense when compared with the PHA coating. DECLARATIONS