Minimally invasive sacroiliac joint fusion: one-year outcomes in 18 patients.

John Cummings, Robyn A Capobianco
{"title":"Minimally invasive sacroiliac joint fusion: one-year outcomes in 18 patients.","authors":"John Cummings,&nbsp;Robyn A Capobianco","doi":"10.1186/1750-1164-7-12","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Sacroiliac joint (SI) pain is an often-overlooked cause of low back pain due, in part, to lack of specific findings on radiographs and symptoms mimicking other back-related disorders. We report our experience with minimally invasive (MIS) SI joint arthrodesis using a series of triangular, titanium plasma spray (TPS) coated implants in patients refractory to conservative care.</p><p><strong>Methods: </strong>We report outcomes from 18 patients with 12 months of postoperative follow-up.Demographics, complications, and clinical outcomes using visual analog scale (VAS) for pain, Oswestry Disability Index (ODI) for back function and SF-12 for quality of life were collected preoperatively and at 3, 6 and 12 months post-operatively.</p><p><strong>Results: </strong>Mean age was 64 years and 67% of patients were female. There were no intraoperative complications and one explant at three months for malposition.All patient-reported outcomes showed both clinically and statistically significant improvement at 12 months (p < 0.001 for each of the following): VAS improved by 6.6 points, ODI scores improved by -37.5 points. One year SF-12 physical and mental component (PCS, MCS) scores approximated population normal scores for both physical and mental functioning. Patient satisfaction with outcomes was high at 95%; 89% said would have the same surgery again.</p><p><strong>Conclusions: </strong>MIS SI joint fusion using a series of triangular porous TPS coated titanium implants is a safe and effective procedure for patients with SI joint disorders who have failed conservative care.</p>","PeriodicalId":87428,"journal":{"name":"Annals of surgical innovation and research","volume":"7 1","pages":"12"},"PeriodicalIF":0.0000,"publicationDate":"2013-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1750-1164-7-12","citationCount":"86","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of surgical innovation and research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1750-1164-7-12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 86

Abstract

Background: Sacroiliac joint (SI) pain is an often-overlooked cause of low back pain due, in part, to lack of specific findings on radiographs and symptoms mimicking other back-related disorders. We report our experience with minimally invasive (MIS) SI joint arthrodesis using a series of triangular, titanium plasma spray (TPS) coated implants in patients refractory to conservative care.

Methods: We report outcomes from 18 patients with 12 months of postoperative follow-up.Demographics, complications, and clinical outcomes using visual analog scale (VAS) for pain, Oswestry Disability Index (ODI) for back function and SF-12 for quality of life were collected preoperatively and at 3, 6 and 12 months post-operatively.

Results: Mean age was 64 years and 67% of patients were female. There were no intraoperative complications and one explant at three months for malposition.All patient-reported outcomes showed both clinically and statistically significant improvement at 12 months (p < 0.001 for each of the following): VAS improved by 6.6 points, ODI scores improved by -37.5 points. One year SF-12 physical and mental component (PCS, MCS) scores approximated population normal scores for both physical and mental functioning. Patient satisfaction with outcomes was high at 95%; 89% said would have the same surgery again.

Conclusions: MIS SI joint fusion using a series of triangular porous TPS coated titanium implants is a safe and effective procedure for patients with SI joint disorders who have failed conservative care.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微创骶髂关节融合术:18例患者的1年疗效。
背景:骶髂关节(SI)疼痛是腰痛的一个经常被忽视的原因,部分原因是由于x线片上缺乏具体的发现和模仿其他背部相关疾病的症状。我们报告了我们使用一系列三角形钛等离子体喷雾(TPS)涂层种植体治疗难以保守治疗的患者的微创(MIS) SI关节融合术的经验。方法:我们报告了18例患者术后12个月随访的结果。术前、术后3个月、6个月和12个月分别采用视觉模拟疼痛评分(VAS)、背部功能评分(ODI)和生活质量评分(SF-12)收集统计数据、并发症和临床结果。结果:患者平均年龄64岁,女性占67%。术中无并发症,术后3个月有一例移位。所有患者报告的结果在12个月时均显示临床和统计学上的显著改善(p)。结论:对于保守治疗失败的SI关节疾病患者,使用一系列三角形多孔TPS涂层钛植入物进行MIS SI关节融合是一种安全有效的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Novel treatments for complications after bariatric surgery Assessment of central venous catheterization in a simulated model using a motion-tracking device: an experimental validation study Current Outcomes of Laparoscopic Duodenal Switch Benefits of intraoperative endoscopy: case report and review of 300 sleeves gastrectomies Development of automated postoperative enteral nutrition: restricting feeding site inflow to match peristaltic outflow
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1