A conventional HPLC-MS method for the simultaneous determination of ofloxacin and cefixime in plasma: Development and validation.

Mahesh V Attimarad, Ahmed O Alnajjar
{"title":"A conventional HPLC-MS method for the simultaneous determination of ofloxacin and cefixime in plasma: Development and validation.","authors":"Mahesh V Attimarad,&nbsp;Ahmed O Alnajjar","doi":"10.4103/0976-0105.113606","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>A simple, rapid, and sensitive high performance liquid chromatography-mass spectrometry (HPLC-MS) method was developed and validated for the simultaneous determination of ofloxacin (OFL) and cefixime (CEF) in human plasma using the moxifloxacin as internal standard.</p><p><strong>Methodology: </strong>Analytes were separated using an Agilent LCMS system equipped with a Zorbax eclipse XBD C18 column (150 mm × 4.6 mm i.d., 5 μm) and using a mobile phase consisting of a mixture of acetonitrile, methanol and 0.5% formic acid in a ratio of 23:10:67% v/v and flow rate was set at 0.6 mL/min. Plasma samples were extracted using the protein precipitation with acetonitrile and analyzed by positive ion mode.</p><p><strong>Results: </strong>The linearity of the proposed method was investigated in the concentration range of 4-500 ng/mL (r = 0.9996) for OFL and 40-6000 ng/mL (r = 0.9998) for CEF. The lower limits of quantification were 4 ng/mL and 40 ng/mL for OFL and CEF respectively, which reach the level of both drugs possibly found in human plasma. Further, the reported method was validated as per the ICH guidelines and found to be well within the acceptable range.</p><p><strong>Conclusion: </strong>The proposed method is simple, rapid, accurate, precise, and appropriate for pharmacokinetic and therapeutic drug monitoring in the clinical laboratories.</p>","PeriodicalId":15046,"journal":{"name":"Journal of Basic and Clinical Pharmacy","volume":"4 2","pages":"36-41"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4103/0976-0105.113606","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Basic and Clinical Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/0976-0105.113606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Objective: A simple, rapid, and sensitive high performance liquid chromatography-mass spectrometry (HPLC-MS) method was developed and validated for the simultaneous determination of ofloxacin (OFL) and cefixime (CEF) in human plasma using the moxifloxacin as internal standard.

Methodology: Analytes were separated using an Agilent LCMS system equipped with a Zorbax eclipse XBD C18 column (150 mm × 4.6 mm i.d., 5 μm) and using a mobile phase consisting of a mixture of acetonitrile, methanol and 0.5% formic acid in a ratio of 23:10:67% v/v and flow rate was set at 0.6 mL/min. Plasma samples were extracted using the protein precipitation with acetonitrile and analyzed by positive ion mode.

Results: The linearity of the proposed method was investigated in the concentration range of 4-500 ng/mL (r = 0.9996) for OFL and 40-6000 ng/mL (r = 0.9998) for CEF. The lower limits of quantification were 4 ng/mL and 40 ng/mL for OFL and CEF respectively, which reach the level of both drugs possibly found in human plasma. Further, the reported method was validated as per the ICH guidelines and found to be well within the acceptable range.

Conclusion: The proposed method is simple, rapid, accurate, precise, and appropriate for pharmacokinetic and therapeutic drug monitoring in the clinical laboratories.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
HPLC-MS同时测定血浆中氧氟沙星和头孢克肟的方法:建立与验证。
目的:建立以莫西沙星为内标同时测定人血浆中氧氟沙星(OFL)和头孢克肟(CEF)含量的高效液相色谱-质谱(HPLC-MS)方法,并进行验证。方法:采用安捷伦LCMS系统,配备Zorbax eclipse XBD C18色谱柱(150 mm × 4.6 mm,直径5 μm),流动相为乙腈、甲醇和0.5%甲酸的混合物,比例为23:10:67% v/v,流速为0.6 mL/min。血浆样品用乙腈蛋白沉淀法提取,用正离子模式分析。结果:本方法在OFL浓度范围4 ~ 500 ng/mL (r = 0.9996)和CEF浓度范围40 ~ 6000 ng/mL (r = 0.9998)内具有良好的线性关系。OFL和CEF的定量下限分别为4 ng/mL和40 ng/mL,达到两种药物在人血浆中可能存在的水平。此外,根据ICH指南对报告的方法进行了验证,发现其完全在可接受的范围内。结论:该方法简便、快速、准确、精密度高,适用于临床实验室药代动力学和治疗药物监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Editorial Note on Flavonoids Evaluation of Controlled Porosity Osmotic Pump for Oral Delivery of Ketorolac Prescribing Pattern and Potency of Anti-Diabetic Drugs in Diabetic Patients for Maintaining Optimal Glycemic Levels Community Pharmacy Practice Towards Cancer Health and the Need for Continuous Cancer Education: Ghana Situation Unusual Case of an Alcoholic with Liver Injury from Sulfasalazine Use
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1