Late removal of titanium hardware from the elbow is problematic.

ISRN orthopedics Pub Date : 2012-02-06 eCollection Date: 2012-01-01 DOI:10.5402/2012/256239
Abdo Bachoura, Ruriko Yoshida, Christian Lattermann, Srinath Kamineni
{"title":"Late removal of titanium hardware from the elbow is problematic.","authors":"Abdo Bachoura,&nbsp;Ruriko Yoshida,&nbsp;Christian Lattermann,&nbsp;Srinath Kamineni","doi":"10.5402/2012/256239","DOIUrl":null,"url":null,"abstract":"<p><p>A retrospective review of 21 patients that underwent bone screw removal from the elbow was studied in relation to the type of metal, duration of implantation, and the location of the screws about the elbow. Screw failure during extraction was the dependent variable. Five of 21 patients experienced hardware failure during extraction. Fourteen patients had titanium alloy implants. In four cases, titanium screws broke during extraction. Compared to stainless steel, titanium screw failure during removal was not statistically significant (P = 0.61). Screw removal 12 months after surgery was more likely to result in broken, retained screws in general (P = 0.046) and specifically for titanium alloy (P = 0.003). Bone screws removed from the distal humerus or proximal ulna had an equal chance of fracturing (P = 0.28). There appears to be a time-related association of titanium alloy bone screw failure during hardware removal cases from the elbow. This may be explained by titanium's properties and osseointegration. </p>","PeriodicalId":89787,"journal":{"name":"ISRN orthopedics","volume":"2012 ","pages":"256239"},"PeriodicalIF":0.0000,"publicationDate":"2012-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2012/256239","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/256239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A retrospective review of 21 patients that underwent bone screw removal from the elbow was studied in relation to the type of metal, duration of implantation, and the location of the screws about the elbow. Screw failure during extraction was the dependent variable. Five of 21 patients experienced hardware failure during extraction. Fourteen patients had titanium alloy implants. In four cases, titanium screws broke during extraction. Compared to stainless steel, titanium screw failure during removal was not statistically significant (P = 0.61). Screw removal 12 months after surgery was more likely to result in broken, retained screws in general (P = 0.046) and specifically for titanium alloy (P = 0.003). Bone screws removed from the distal humerus or proximal ulna had an equal chance of fracturing (P = 0.28). There appears to be a time-related association of titanium alloy bone screw failure during hardware removal cases from the elbow. This may be explained by titanium's properties and osseointegration.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
较晚从肘部取出钛金属是有问题的。
回顾性分析了21例肘关节骨螺钉取出患者,研究了金属类型、植入时间和肘关节螺钉位置的关系。提取过程中螺钉失效是因变量。21例患者中有5例在拔牙过程中出现硬件故障。14例患者采用钛合金种植体。在4例中,钛螺钉在拔牙过程中断裂。与不锈钢螺钉相比,钛螺钉在拆卸过程中的失效无统计学意义(P = 0.61)。术后12个月取出螺钉更容易导致螺钉断裂和保留(P = 0.046),特别是钛合金螺钉(P = 0.003)。从肱骨远端或尺骨近端取下螺钉发生骨折的几率相同(P = 0.28)。在肘关节内固定取出病例中,钛合金骨螺钉失效似乎与时间有关。这可以用钛的性质和骨整合来解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic hip screw for the treatment of femoral neck fractures: a prospective study with 96 patients. A staged surgical treatment outcome of type 3 open tibial fractures. Treatment options for brachial plexus injuries. Normal range of thoracic kyphosis in male school children. Comparison of functional outcomes of tibial plateau fractures treated with nonlocking and locking plate fixations: a nonrandomized clinical trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1