Insomnia and sleep misperception

C.H. Bastien , T. Ceklic , P. St-Hilaire , F. Desmarais , A.D. Pérusse , J. Lefrançois , M. Pedneault-Drolet
{"title":"Insomnia and sleep misperception","authors":"C.H. Bastien ,&nbsp;T. Ceklic ,&nbsp;P. St-Hilaire ,&nbsp;F. Desmarais ,&nbsp;A.D. Pérusse ,&nbsp;J. Lefrançois ,&nbsp;M. Pedneault-Drolet","doi":"10.1016/j.patbio.2014.07.003","DOIUrl":null,"url":null,"abstract":"<div><p>Sleep misperception is often observed in insomnia individuals (INS). The extent of misperception varies between different types of INS. The following paper comprised sections which will be aimed at studying the sleep EEG and compares it to subjective reports of sleep in individuals suffering from either psychophysiological insomnia or paradoxical insomnia and good sleeper controls. The EEG can be studied without any intervention (thus using the raw data) via either PSG or fine quantitative EEG analyses (power spectral analysis [PSA]), identifying EEG patterns as in the case of cyclic alternating patterns (CAPs) or by decorticating the EEG while scoring the different transient or phasic events (K-Complexes or sleep spindles). One can also act on the on-going EEG by delivering stimuli so to study their impact on cortical measures as in the case of event-related potential studies (ERPs). From the paucity of studies available using these different techniques, a general conclusion can be reached: sleep misperception is not an easy phenomenon to quantify and its clinical value is not well recognized. Still, while none of the techniques or EEG measures defined in the paper is available and/or recommended to diagnose insomnia, ERPs might be the most indicated technique to study hyperarousal and sleep quality in different types of INS. More research shall also be dedicated to EEG patterns and transient phasic events as these EEG scoring techniques can offer a unique insight of sleep misperception.</p></div>","PeriodicalId":19743,"journal":{"name":"Pathologie-biologie","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.patbio.2014.07.003","citationCount":"51","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pathologie-biologie","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0369811414000947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 51

Abstract

Sleep misperception is often observed in insomnia individuals (INS). The extent of misperception varies between different types of INS. The following paper comprised sections which will be aimed at studying the sleep EEG and compares it to subjective reports of sleep in individuals suffering from either psychophysiological insomnia or paradoxical insomnia and good sleeper controls. The EEG can be studied without any intervention (thus using the raw data) via either PSG or fine quantitative EEG analyses (power spectral analysis [PSA]), identifying EEG patterns as in the case of cyclic alternating patterns (CAPs) or by decorticating the EEG while scoring the different transient or phasic events (K-Complexes or sleep spindles). One can also act on the on-going EEG by delivering stimuli so to study their impact on cortical measures as in the case of event-related potential studies (ERPs). From the paucity of studies available using these different techniques, a general conclusion can be reached: sleep misperception is not an easy phenomenon to quantify and its clinical value is not well recognized. Still, while none of the techniques or EEG measures defined in the paper is available and/or recommended to diagnose insomnia, ERPs might be the most indicated technique to study hyperarousal and sleep quality in different types of INS. More research shall also be dedicated to EEG patterns and transient phasic events as these EEG scoring techniques can offer a unique insight of sleep misperception.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
失眠和睡眠错觉
在失眠个体(INS)中经常观察到睡眠错觉。误解的程度因不同类型的INS而异。下面的论文将包括几个部分,旨在研究睡眠脑电图,并将其与患有心理生理性失眠或矛盾性失眠和良好睡眠控制的个体的主观睡眠报告进行比较。通过PSG或精细的定量脑电图分析(功率谱分析[PSA]),可以在没有任何干预的情况下(因此使用原始数据)研究脑电图,识别周期性交替模式(CAPs)的脑电图模式,或者在对不同的瞬态或阶段性事件(k -复合体或睡眠纺锤波)进行评分时对脑电图进行去皮。在事件相关电位研究(event- relevant potential studies, ERPs)中,人们也可以通过传递刺激来作用于正在进行的脑电图,以研究它们对皮层测量的影响。从使用这些不同技术的可用研究的缺乏来看,可以得出一个总的结论:睡眠错觉不是一个容易量化的现象,其临床价值也没有得到很好的认识。然而,虽然论文中定义的技术或脑电图测量方法都不能用于诊断失眠,或推荐用于诊断失眠,但erp可能是研究不同类型INS中过度觉醒和睡眠质量的最有效技术。更多的研究还应致力于脑电图模式和瞬态相事件,因为这些脑电图评分技术可以为睡眠错觉提供独特的见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pathologie-biologie
Pathologie-biologie 医学-病理学
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊最新文献
[Filaggrin]. Editorial board Protective effect of Fenofibrate in renal ischemia reperfusion injury: Involved in suppressing kinase 2 (JAK2)/transcription 3 (STAT3)/p53 signaling activation Longevity and aging. Mechanisms and perspectives PKCs in thrombus formation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1