{"title":"Detection of autoantibodies in a point-of-care rheumatology setting.","authors":"Konstantin N Konstantinov, Antonios Tzamaloukas, Robert L Rubin","doi":"10.1007/s13317-013-0052-9","DOIUrl":null,"url":null,"abstract":"<p><p>Autoimmune rheumatic diseases are common and confront society with serious medical, social, and financial burdens imposed by their debilitating nature. Many autoimmune diseases are associated with a particular set of autoantibodies, which have emerged as highly useful to define and classify disease, predict flares, or monitor efficacy of therapy. However, current practice for monitoring autoantibodies is protracted, labor-intensive, and expensive. This review provides an overview on the value of point-of-care (POC) biosensor technology in the diagnosis and management of patients with autoimmune rheumatic diseases. Real-time measurement of autoantibodies will clearly benefit the rheumatology practice in emergency and urgent care settings, where definitive diagnosis is essential for initiation of correct critical care therapy. Immediate serological information in clinic will provide considerable value for long-term patient care and an opportunity for an instant, result-deduced therapeutic action, avoiding delays and improving compliance, especially in field-based and remote areas. We describe the particular autoantibodies that are useful disease and activity markers and would, therefore, be attractive to POC applications. Already existing biosensors and platforms that show promise for autoantibody testing are summarized and comparatively evaluated. As POC assessment is gaining momentum in several areas of patient care, we propose that rheumatology is poised to benefit from this innovative and affordable technology. </p>","PeriodicalId":8655,"journal":{"name":"Auto-Immunity Highlights","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4389050/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Auto-Immunity Highlights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13317-013-0052-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/8/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Autoimmune rheumatic diseases are common and confront society with serious medical, social, and financial burdens imposed by their debilitating nature. Many autoimmune diseases are associated with a particular set of autoantibodies, which have emerged as highly useful to define and classify disease, predict flares, or monitor efficacy of therapy. However, current practice for monitoring autoantibodies is protracted, labor-intensive, and expensive. This review provides an overview on the value of point-of-care (POC) biosensor technology in the diagnosis and management of patients with autoimmune rheumatic diseases. Real-time measurement of autoantibodies will clearly benefit the rheumatology practice in emergency and urgent care settings, where definitive diagnosis is essential for initiation of correct critical care therapy. Immediate serological information in clinic will provide considerable value for long-term patient care and an opportunity for an instant, result-deduced therapeutic action, avoiding delays and improving compliance, especially in field-based and remote areas. We describe the particular autoantibodies that are useful disease and activity markers and would, therefore, be attractive to POC applications. Already existing biosensors and platforms that show promise for autoantibody testing are summarized and comparatively evaluated. As POC assessment is gaining momentum in several areas of patient care, we propose that rheumatology is poised to benefit from this innovative and affordable technology.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在风湿病护理点检测自身抗体。
自身免疫性风湿病是一种常见病,其致残性给社会带来了严重的医疗、社会和经济负担。许多自身免疫性疾病都与一组特殊的自身抗体有关,这些抗体对于疾病的定义和分类、预测复发或监测疗效非常有用。然而,目前监测自身抗体的做法旷日持久、耗费人力且成本高昂。本综述概述了护理点(POC)生物传感器技术在诊断和管理自身免疫性风湿病患者方面的价值。在急诊和紧急护理环境中,自身抗体的实时测量将明显有利于风湿病学实践,因为在这些环境中,明确诊断对于启动正确的重症护理治疗至关重要。门诊中的即时血清学信息将为患者的长期治疗提供相当大的价值,并为根据结果采取即时治疗行动提供机会,避免延误并提高依从性,尤其是在野外和偏远地区。我们描述了一些特殊的自身抗体,它们是有用的疾病和活动标记物,因此对 POC 应用很有吸引力。我们还总结并比较评估了现有的生物传感器和平台,它们在自身抗体检测方面表现出了良好的前景。随着 POC 评估技术在多个患者护理领域的应用日益广泛,我们认为风湿病学有望从这一创新且经济实惠的技术中获益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Potential clinical biomarkers in rheumatoid arthritis with an omic approach. Effect of janus kinase inhibitors and methotrexate combination on malignancy in patients with rheumatoid arthritis: a systematic review and meta-analysis of randomized controlled trials. Short-chain fatty acids and intestinal inflammation in multiple sclerosis: modulation of female susceptibility by microbial products? Endogenous mitochondrial double-stranded RNA is not an activator of the type I interferon response in human pancreatic beta cells. Sustained clinical remission under infliximab/rituximab combination therapy in a patient with granulomatosis with polyangiitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1