Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.

Q1 Medicine Auto-Immunity Highlights Pub Date : 2014-07-18 eCollection Date: 2014-09-01 DOI:10.1007/s13317-014-0059-x
Carmen Gelpí, Elena Pérez, Cristina Roldan
{"title":"Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.","authors":"Carmen Gelpí,&nbsp;Elena Pérez,&nbsp;Cristina Roldan","doi":"10.1007/s13317-014-0059-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to compare the degree of agreement of a novel Zenit RA chemiluminescent immunoassay (CLIA) from A. Menarini Diagnostics (Florence, Italy) and the gold standard immunoprecipitation assay to screen for the presence of specific anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl-70(Topo I) antibodies.</p><p><strong>Materials and methods: </strong>We studied 114 sera, 98 from patients with well-defined autoimmune connective tissue diseases and 16 from blood donor volunteers. All samples were fully characterized using the new chemiluminescent immunoassay and immunoprecipitation. In addition, all the samples were analyzed by indirect immunofluorescence (IIF) and anti-Scl-70(Topo I) antibodies were analyzed by immunoblot (IB) assay. Discrepant samples were analyzed using a commercial dot blot technique (Recomline from Mikrogen). The simple Kappa coefficient was used to measure the level of agreement between the results of Zenit RA CLIA and the gold standard.</p><p><strong>Results: </strong>The Kappa agreement between Zenit RA CLIA and gold standard immunoprecipitation, as well as IB and IIFassays for the presence of anti-Scl-70(Topo I)(0.948) was excellent. The concordance between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-U1snRNP (0.883), anti-Ro/SS-A (0.878), anti-Jo-1((his)tRNA-Synthetase) (0.791) and anti-Sm (0.786) was good, and excellent when the cut-off was raised to 14 U/ml (arbitrary units/ml). Between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-La/SS-B, the Kappa agreement had a value of 0.689, but this improved to 0.775 when the cut-off was raised to14 U/ml. Precision was good based on the evaluation of replicate samples. Inter-assay coefficient variation was lower than 3.4 % (CV in %) in all the kits and <1.2 % (CV in  %) for intra-assay measurements.</p><p><strong>Conclusion: </strong>Our findings show that Zenit RA CLIA was specific and sensitive to detect anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl70(Topo I) autoantibodies. This simple, fast and precise method can be a suitable option to analyze these autoantibody specificities.</p>","PeriodicalId":8655,"journal":{"name":"Auto-Immunity Highlights","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s13317-014-0059-x","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Auto-Immunity Highlights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13317-014-0059-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/9/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 10

Abstract

Purpose: The aim of this study was to compare the degree of agreement of a novel Zenit RA chemiluminescent immunoassay (CLIA) from A. Menarini Diagnostics (Florence, Italy) and the gold standard immunoprecipitation assay to screen for the presence of specific anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl-70(Topo I) antibodies.

Materials and methods: We studied 114 sera, 98 from patients with well-defined autoimmune connective tissue diseases and 16 from blood donor volunteers. All samples were fully characterized using the new chemiluminescent immunoassay and immunoprecipitation. In addition, all the samples were analyzed by indirect immunofluorescence (IIF) and anti-Scl-70(Topo I) antibodies were analyzed by immunoblot (IB) assay. Discrepant samples were analyzed using a commercial dot blot technique (Recomline from Mikrogen). The simple Kappa coefficient was used to measure the level of agreement between the results of Zenit RA CLIA and the gold standard.

Results: The Kappa agreement between Zenit RA CLIA and gold standard immunoprecipitation, as well as IB and IIFassays for the presence of anti-Scl-70(Topo I)(0.948) was excellent. The concordance between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-U1snRNP (0.883), anti-Ro/SS-A (0.878), anti-Jo-1((his)tRNA-Synthetase) (0.791) and anti-Sm (0.786) was good, and excellent when the cut-off was raised to 14 U/ml (arbitrary units/ml). Between Zenit RA CLIA and gold standard immunoprecipitation for the presence of anti-La/SS-B, the Kappa agreement had a value of 0.689, but this improved to 0.775 when the cut-off was raised to14 U/ml. Precision was good based on the evaluation of replicate samples. Inter-assay coefficient variation was lower than 3.4 % (CV in %) in all the kits and <1.2 % (CV in  %) for intra-assay measurements.

Conclusion: Our findings show that Zenit RA CLIA was specific and sensitive to detect anti-U1snRNP, anti-Sm, anti-Ro/SS-A, anti-La/SS-B, anti-Jo-1((his)tRNA-Synthetase) and anti-Scl70(Topo I) autoantibodies. This simple, fast and precise method can be a suitable option to analyze these autoantibody specificities.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
固相化学发光免疫分析法检测抗核和细胞质自身抗体的效率与金标准免疫沉淀法的比较。
目的:本研究的目的是比较a . Menarini诊断公司(佛罗伦萨,意大利)的新型Zenit RA化学发光免疫分析法(CLIA)和金标准免疫沉淀法筛选特异性抗u1snrnp、抗sm、抗ro /SS-A、抗la /SS-B、抗jo -1(his) trna合成酶)和抗scl -70(Topo I)抗体的一致性程度。材料和方法:我们研究了114份血清,其中98份来自明确的自身免疫性结缔组织疾病患者,16份来自献血者志愿者。所有样品都使用新的化学发光免疫测定和免疫沉淀进行了充分的表征。采用间接免疫荧光法(IIF)和免疫印迹法(IB)检测抗scl -70(Topo I)抗体。使用商用点印迹技术(来自Mikrogen公司的Recomline)分析差异样品。简单Kappa系数用于衡量Zenit RA CLIA结果与金标准之间的一致程度。结果:Zenit RA CLIA与金标准免疫沉淀、IB和iifa检测抗scl -70(Topo I)存在的Kappa一致性(0.948)极好。Zenit RA CLIA与金标准免疫沉淀对抗u1snrnp(0.883)、抗ro /SS-A(0.878)、抗jo -1(his) trna合成酶)(0.791)和抗sm(0.786)的一致性较好,当截止值提高到14 U/ml(任意单位/ml)时,一致性良好。在Zenit RA CLIA和存在抗la /SS-B的金标准免疫沉淀之间,Kappa一致性值为0.689,但当截止值提高到14 U/ml时,Kappa一致性值提高到0.775。根据重复样品的评价,精密度良好。结论:Zenit RA CLIA试剂盒检测抗u1snrnp、抗sm、抗ro /SS-A、抗la /SS-B、抗jo -1(his) trna合成酶)和抗scl70 (Topo I)自身抗体具有特异性和敏感性。这种简单、快速和精确的方法是分析这些自身抗体特异性的合适选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Potential clinical biomarkers in rheumatoid arthritis with an omic approach. Effect of janus kinase inhibitors and methotrexate combination on malignancy in patients with rheumatoid arthritis: a systematic review and meta-analysis of randomized controlled trials. Short-chain fatty acids and intestinal inflammation in multiple sclerosis: modulation of female susceptibility by microbial products? Endogenous mitochondrial double-stranded RNA is not an activator of the type I interferon response in human pancreatic beta cells. Sustained clinical remission under infliximab/rituximab combination therapy in a patient with granulomatosis with polyangiitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1