Incidence and Risk Factors of Repositioning Surgery to Correct Misalignment of Toric Intraocular Lenses after Cataract Surgery: A Single-Center Retrospective Observational Study.
{"title":"Incidence and Risk Factors of Repositioning Surgery to Correct Misalignment of Toric Intraocular Lenses after Cataract Surgery: A Single-Center Retrospective Observational Study.","authors":"Honglei Li, Jiajun Sun, Huiran Bai, Lin Leng, Yunhai Dai, Xiaoming Wu","doi":"10.1159/000527408","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to analyze the incidence and outcomes of repositioning surgery to correct misalignment of several toric intraocular lenses (IOLs) after cataract surgery.</p><p><strong>Methods: </strong>In this retrospective study, patients who underwent repositioning surgery to correct misalignment of toric IOLs following cataract surgery between January 2019 and December 2021 were enrolled. The medical data on patients' age, gender, preoperative axial length, corneal astigmatism, the axis of astigmatism, IOL models, IOL axis, uncorrected distance visual acuity, residual refraction, and postoperative outcomes were analyzed.</p><p><strong>Results: </strong>Among the 1,135 eyes implanted with toric IOLs at Qingdao Eye Hospital, 23 (2.026%, 23/1,135) underwent repositioning surgery. Univariate analysis revealed that the incidence of repositioning surgery was significantly lower with AcrySof (0.636%, 5/786) than with ZEISS (2.959%, 5/169) and TECNIS (7.222%, 13/180) IOL platforms; the incidence of repositioning surgery with monofocal toric IOLs (1.169%, 11/941) was significantly lower than multifocal toric IOLs (6.186%, 12/194) (p < 0.001); additionally, a significant difference in age was also observed (p = 0.002). Multivariate logistic regression analysis showed that the IOL platform (p = 0.004) and younger age (p = 0.006) were independent risk factors for repositioning surgery.</p><p><strong>Conclusion: </strong>The incidence of repositioning surgery of toric IOLs after cataract surgery was 2.026%. It was linked to the IOL platform, multifocal toric IOLs, and younger age.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"259-264"},"PeriodicalIF":4.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000527408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/12 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The aim of this study was to analyze the incidence and outcomes of repositioning surgery to correct misalignment of several toric intraocular lenses (IOLs) after cataract surgery.
Methods: In this retrospective study, patients who underwent repositioning surgery to correct misalignment of toric IOLs following cataract surgery between January 2019 and December 2021 were enrolled. The medical data on patients' age, gender, preoperative axial length, corneal astigmatism, the axis of astigmatism, IOL models, IOL axis, uncorrected distance visual acuity, residual refraction, and postoperative outcomes were analyzed.
Results: Among the 1,135 eyes implanted with toric IOLs at Qingdao Eye Hospital, 23 (2.026%, 23/1,135) underwent repositioning surgery. Univariate analysis revealed that the incidence of repositioning surgery was significantly lower with AcrySof (0.636%, 5/786) than with ZEISS (2.959%, 5/169) and TECNIS (7.222%, 13/180) IOL platforms; the incidence of repositioning surgery with monofocal toric IOLs (1.169%, 11/941) was significantly lower than multifocal toric IOLs (6.186%, 12/194) (p < 0.001); additionally, a significant difference in age was also observed (p = 0.002). Multivariate logistic regression analysis showed that the IOL platform (p = 0.004) and younger age (p = 0.006) were independent risk factors for repositioning surgery.
Conclusion: The incidence of repositioning surgery of toric IOLs after cataract surgery was 2.026%. It was linked to the IOL platform, multifocal toric IOLs, and younger age.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.