{"title":"Analysis of Cationic Vitamins in Cell Culture Medium Samples by Capillary Zone Electrophoresis.","authors":"Debbie van der Burg, Hermann Wätzig, Cari E Sänger-van de Griend","doi":"10.1155/2022/2819855","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes a capillary electrophoresis method for the determination of the cationic B-vitamins thiamine, nicotinamide, pyridoxine, pyridoxal, and pyridoxamine in untreated cell culture medium samples. The effects of the buffering capacity, the mobility of the coion, and the preconditioning solution on the robustness of the method were investigated. Using a 100 mM phosphoric acid and 55 mM triethanolamine background electrolyte at pH 2.3 and capillary preconditioning with 1 M NaOH, all five vitamins could be separated with good resolution. Preliminary method validation data over the range 10-110 <i>µ</i>M for undiluted samples, with 10 <i>μ</i>M being the lower range limit of quantification QL, showed accuracy recoveries of 94-104%, and migration time and peak area repeatabilities within 0.4% RSD and 2.6% RSD, respectively.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"2819855"},"PeriodicalIF":4.7000,"publicationDate":"2022-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9560846/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2022/2819855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
This paper describes a capillary electrophoresis method for the determination of the cationic B-vitamins thiamine, nicotinamide, pyridoxine, pyridoxal, and pyridoxamine in untreated cell culture medium samples. The effects of the buffering capacity, the mobility of the coion, and the preconditioning solution on the robustness of the method were investigated. Using a 100 mM phosphoric acid and 55 mM triethanolamine background electrolyte at pH 2.3 and capillary preconditioning with 1 M NaOH, all five vitamins could be separated with good resolution. Preliminary method validation data over the range 10-110 µM for undiluted samples, with 10 μM being the lower range limit of quantification QL, showed accuracy recoveries of 94-104%, and migration time and peak area repeatabilities within 0.4% RSD and 2.6% RSD, respectively.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.