Evaluation of an immunochromatographic test for feline AB system blood typing.

Eva Spada, Daniela Proverbio, Luciana Baggiani, Giada Bagnagatti De Giorgi, Roberta Perego, Elisabetta Ferro
{"title":"Evaluation of an immunochromatographic test for feline AB system blood typing.","authors":"Eva Spada,&nbsp;Daniela Proverbio,&nbsp;Luciana Baggiani,&nbsp;Giada Bagnagatti De Giorgi,&nbsp;Roberta Perego,&nbsp;Elisabetta Ferro","doi":"10.1111/vec.12360","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the accuracy of an immunochromatographic cartridge (IC) test for blood typing feline type A, B, and AB blood samples.</p><p><strong>Design: </strong>Prospective observational study.</p><p><strong>Setting: </strong>University teaching hospital.</p><p><strong>Samples: </strong>Fifty-one nonanemic and 19 anemic feline blood samples.</p><p><strong>Interventions: </strong>Samples were blood typed by both card agglutination (CA) and IC techniques. Discordant results were analyzed using a back-typing technique for the presence of alloantibodies. Repeatability and reproducibility of the IC method were evaluated. Accuracy of the IC method was determined for feline whole blood anticoagulated with EDTA and citrate phosphate dextrose adenine (CPDA1), for feline-packed RBCs with CPDA1 and saline adenine glucose-mannitol, and for autoagglutinated and hemolytic samples. Accuracy of IC testing was determined for feline blood after room temperature, 4 ± 2, -20, and -80°C storage following 24, 48, 72, and 96 hours, and after 1, 2, 3, and 4 weeks of storage.</p><p><strong>Measurements and main results: </strong>In anemic and nonanemic samples the IC technique had a specificity, sensitivity, positive predictive value, and negative predictive value of 100% in detecting feline blood types A, B, and AB, outperforming a CA test. Results were repeatable and reproducible. Using IC it was possible to blood type samples anticoagulated with EDTA and CPDA1, packed RBC samples with CPDA1 and saline adenine glucose-mannitol, autoagglutinated and hemolytic samples, and samples stored at 4 ± 2°C and at room temperature for up to 1 month.</p><p><strong>Conclusions: </strong>The IC technique is an accurate assay for the identification of A, B, and AB blood types in anemic and nonanemic feline blood. It has a higher sensitivity and specificity than the CA test, and can be used in samples stored with common anticoagulants or preservative solutions used in feline transfusion medicine.</p>","PeriodicalId":74015,"journal":{"name":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/vec.12360","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/vec.12360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/8/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Objective: To determine the accuracy of an immunochromatographic cartridge (IC) test for blood typing feline type A, B, and AB blood samples.

Design: Prospective observational study.

Setting: University teaching hospital.

Samples: Fifty-one nonanemic and 19 anemic feline blood samples.

Interventions: Samples were blood typed by both card agglutination (CA) and IC techniques. Discordant results were analyzed using a back-typing technique for the presence of alloantibodies. Repeatability and reproducibility of the IC method were evaluated. Accuracy of the IC method was determined for feline whole blood anticoagulated with EDTA and citrate phosphate dextrose adenine (CPDA1), for feline-packed RBCs with CPDA1 and saline adenine glucose-mannitol, and for autoagglutinated and hemolytic samples. Accuracy of IC testing was determined for feline blood after room temperature, 4 ± 2, -20, and -80°C storage following 24, 48, 72, and 96 hours, and after 1, 2, 3, and 4 weeks of storage.

Measurements and main results: In anemic and nonanemic samples the IC technique had a specificity, sensitivity, positive predictive value, and negative predictive value of 100% in detecting feline blood types A, B, and AB, outperforming a CA test. Results were repeatable and reproducible. Using IC it was possible to blood type samples anticoagulated with EDTA and CPDA1, packed RBC samples with CPDA1 and saline adenine glucose-mannitol, autoagglutinated and hemolytic samples, and samples stored at 4 ± 2°C and at room temperature for up to 1 month.

Conclusions: The IC technique is an accurate assay for the identification of A, B, and AB blood types in anemic and nonanemic feline blood. It has a higher sensitivity and specificity than the CA test, and can be used in samples stored with common anticoagulants or preservative solutions used in feline transfusion medicine.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
免疫层析测试对猫AB系统血型的评价。
目的:确定免疫层析墨盒(IC)试验对猫A、B和AB型血液样本进行分型的准确性。设计:前瞻性观察研究。单位:大学教学医院。样本:51只非贫血猫和19只贫血猫的血液样本。干预措施:通过卡片凝集(CA)和IC技术对样本进行血型分型。使用反向分型技术分析不一致的结果是否存在同种异体抗体。评价了IC法的重复性和再现性。测定了用EDTA和柠檬酸磷酸葡萄糖腺嘌呤(CPDA1)抗凝的猫全血、用CPDA1和生理盐水腺嘌呤葡萄糖-甘露醇包装的猫红细胞以及自体凝集和溶血样品的IC方法的准确性。测定猫血在室温、4±2、-20和-80℃保存24、48、72和96小时,以及保存1、2、3和4周后IC检测的准确性。测量结果和主要结果:在贫血和非贫血样品中,IC技术检测猫血型a、B和AB的特异性、敏感性、阳性预测值和阴性预测值均为100%,优于CA检测。结果可重复性好,重现性好。使用IC可以对EDTA和CPDA1抗凝的血液样本、CPDA1和生理盐水腺嘌呤葡萄糖甘露醇包装的红细胞样本、自凝集和溶血样本、在4±2℃和室温下保存长达1个月的样本进行血型分析。结论:IC技术是一种能够准确鉴别猫血中A、B和AB血型的方法。它比CA试验具有更高的敏感性和特异性,可用于与猫输血药物中常用的抗凝血剂或防腐剂溶液一起保存的样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Owner experiences with and perceptions of owner-witnessed CPR in veterinary medicine. Development and implementation of a hemovigilance program at a university veterinary teaching hospital. 2022 Update of the Consensus on the Rational Use of Antithrombotics and Thrombolytics in Veterinary Critical Care (CURATIVE) Domain 1- Defining populations at risk. Abstracts from the International Veterinary Emergency and Critical Care Symposium, and the European Veterinary Emergency and Critical Care Annual Congress 2021. Abstracts from the International Veterinary Emergency and Critical Care Symposium, and the European Veterinary Emergency and Critical Care Annual Congress 2020.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1