Modeling of Drug Delivery by A Pump Driven Micro-Needle Array System.

Q3 Medicine Open Biomedical Engineering Journal Pub Date : 2016-03-30 eCollection Date: 2016-01-01 DOI:10.2174/1874120701610010019
Kai Chen, Min Pan, Zhi-Gang Feng
{"title":"Modeling of Drug Delivery by A Pump Driven Micro-Needle Array System.","authors":"Kai Chen,&nbsp;Min Pan,&nbsp;Zhi-Gang Feng","doi":"10.2174/1874120701610010019","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Micro-needles were proposed as one of the alternatives to deliver drugs painlessly passing through stratum corneum in recent years. In this work, a mathematical model is presented to characterize the in fusion flow of a hollow micro-needle array driven by a micro-pump.</p><p><strong>Methods: </strong>By assuming the injection of each micro-needle undergoes a spherical expansion and diffusion, the model is able to calculate the time-varying expansion radius, and the diffusion boundary, provided that the material properties and the micro-needle system parameters are known.</p><p><strong>Results and conclusion: </strong>The calculation results show that the expansion caused by the infusion of micro-needles stops and the flow rate drops to zero in a short time. However, the diffusion boundary is much bigger than the expansion and the infusion continues if the surrounding material is absorptive. The experimental results of jet infusion through a single needle in silicon rubber and polyacrylamide gel agree with the calculation results qualitatively.</p>","PeriodicalId":39121,"journal":{"name":"Open Biomedical Engineering Journal","volume":"10 ","pages":"19-33"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874120701610010019","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Biomedical Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874120701610010019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 8

Abstract

Background: Micro-needles were proposed as one of the alternatives to deliver drugs painlessly passing through stratum corneum in recent years. In this work, a mathematical model is presented to characterize the in fusion flow of a hollow micro-needle array driven by a micro-pump.

Methods: By assuming the injection of each micro-needle undergoes a spherical expansion and diffusion, the model is able to calculate the time-varying expansion radius, and the diffusion boundary, provided that the material properties and the micro-needle system parameters are known.

Results and conclusion: The calculation results show that the expansion caused by the infusion of micro-needles stops and the flow rate drops to zero in a short time. However, the diffusion boundary is much bigger than the expansion and the infusion continues if the surrounding material is absorptive. The experimental results of jet infusion through a single needle in silicon rubber and polyacrylamide gel agree with the calculation results qualitatively.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
泵驱动微针阵列给药系统的建模。
背景:近年来,微针被认为是通过角质层无痛给药的替代方法之一。本文建立了一个由微泵驱动的空心微针阵列熔合流的数学模型。方法:在已知材料性质和微针系统参数的情况下,假设每个微针的注射都经历一个球形的膨胀扩散过程,计算出随时间变化的膨胀半径和扩散边界。结果与结论:计算结果表明,微针输注引起的膨胀在短时间内停止,流速降至零。然而,扩散边界远大于膨胀边界,如果周围物质具有吸附性,则注入过程将继续进行。单针喷射注射硅橡胶和聚丙烯酰胺凝胶的实验结果与计算结果定性一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Open Biomedical Engineering Journal
Open Biomedical Engineering Journal Medicine-Medicine (miscellaneous)
CiteScore
1.60
自引率
0.00%
发文量
4
期刊最新文献
F.E.M. Stress-Investigation of Scolios Apex. Characterization of the F-box Proteins FBXW2 and FBXL14 in the Initiation of Bone Regeneration in Transplants given to Nude Mice. Natural Sensations Evoked in Distal Extremities Using Surface Electrical Stimulation. Investigating the Conformation of S100β Protein Under Physiological Parameters Using Computational Modeling: A Clue for Rational Drug Design. Reliability, Learnability and Efficiency of Two Tools for Cement Crowns Retrieval in Dentistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1