Light diffusion through composite restorations added with spherical glass mega fillers.

ORAL and Implantology Pub Date : 2017-02-14 eCollection Date: 2016-01-01 DOI:10.11138/orl/2016.9.1S.080
M Andreasi Bassi, S Andreasi Bassi, C Andrisani, S Lico, L Baggi, D Lauritano
{"title":"Light diffusion through composite restorations added with spherical glass mega fillers.","authors":"M Andreasi Bassi,&nbsp;S Andreasi Bassi,&nbsp;C Andrisani,&nbsp;S Lico,&nbsp;L Baggi,&nbsp;D Lauritano","doi":"10.11138/orl/2016.9.1S.080","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Evaluate how the spherical glass mega fillers (SGMFs) can positively interfere with light diffusion when incorporated in a composite restoration.</p><p><strong>Materials and methods: </strong>30 samples (Ss) were performed, applying 2 composite layers of 3 mm each: 6 were made with composite only; 6 with a layer of SGMFs of O1.5mm within the first layer of composite; 6 with 2 overlapping layers of SGMFs of O1.5mm; 6 with a layer of SGMFs of O2mm; 6 with 2 overlapping layers of SGMFs of O2mm. The curing time was set at 40s for the first layer, and 120s for the second layer, transilluminated through the first layer. Digital pictures were taken, in standardized settings, during the transillumination, and the light intensity was measured with a digital image analysis software.</p><p><strong>Results: </strong>From a lateral view the Ss with a single layer of SGMFs of O1.5mm and O2mm, the relative increments of light intensity, were of 24.37% and 33.33% respectively. Concerning the Ss made with 2 layers of SGMFs, the relative increments were of 67.99% and 66.4% respectively. In front view has emerged a relative increase rate of light intensity of 53.66% and 79.58%, in the Ss with a single layer of SGMFs of O1.5mm and of O2mm respectively. Furthermore, in the Ss with two layers of SGMFs of O1.5mm and O2mm the relative increments were of 267.53 and 319.63% respectively.</p><p><strong>Conclusion: </strong>The SGMFs are reliable in facilitating light diffusion within the light-curing composite resins.</p>","PeriodicalId":38303,"journal":{"name":"ORAL and Implantology","volume":"9 Suppl 1-2016 to N 4-2016","pages":"80-89"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5333743/pdf/80-89.pdf","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORAL and Implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11138/orl/2016.9.1S.080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Purpose: Evaluate how the spherical glass mega fillers (SGMFs) can positively interfere with light diffusion when incorporated in a composite restoration.

Materials and methods: 30 samples (Ss) were performed, applying 2 composite layers of 3 mm each: 6 were made with composite only; 6 with a layer of SGMFs of O1.5mm within the first layer of composite; 6 with 2 overlapping layers of SGMFs of O1.5mm; 6 with a layer of SGMFs of O2mm; 6 with 2 overlapping layers of SGMFs of O2mm. The curing time was set at 40s for the first layer, and 120s for the second layer, transilluminated through the first layer. Digital pictures were taken, in standardized settings, during the transillumination, and the light intensity was measured with a digital image analysis software.

Results: From a lateral view the Ss with a single layer of SGMFs of O1.5mm and O2mm, the relative increments of light intensity, were of 24.37% and 33.33% respectively. Concerning the Ss made with 2 layers of SGMFs, the relative increments were of 67.99% and 66.4% respectively. In front view has emerged a relative increase rate of light intensity of 53.66% and 79.58%, in the Ss with a single layer of SGMFs of O1.5mm and of O2mm respectively. Furthermore, in the Ss with two layers of SGMFs of O1.5mm and O2mm the relative increments were of 267.53 and 319.63% respectively.

Conclusion: The SGMFs are reliable in facilitating light diffusion within the light-curing composite resins.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过添加球形玻璃填充剂的复合修复体进行光扩散。
目的:评估球形玻璃mega填料(SGMFs)在复合修复中如何积极干涉光扩散。材料和方法:30个样品(s),采用2层复合材料,每层3 mm: 6只复合材料;6 .复合材料第一层内加一层O1.5mm的SGMFs;6层O1.5mm的SGMFs重叠2层;6用一层O2mm的SGMFs;6, 2层O2mm的SGMFs重叠。第一层固化时间设置为40s,第二层固化时间设置为120s,通过第一层进行透照。在标准化设置下,在透照过程中拍摄数字照片,并使用数字图像分析软件测量光强。结果:单层sgmf为O1.5mm和O2mm的Ss,从侧面看,光强的相对增量分别为24.37%和33.33%。2层SGMFs的Ss相对增量分别为67.99%和66.4%。前视光强相对增加率分别为53.66%和79.58%,分别为单层O1.5mm和O2mm的SGMFs。此外,在O1.5mm和O2mm两层SGMFs的Ss中,相对增量分别为267.53和319.63%。结论:SGMFs在光固化复合树脂中具有促进光扩散的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ORAL and Implantology
ORAL and Implantology Dentistry-Dentistry (all)
自引率
0.00%
发文量
0
期刊最新文献
Risk assessment of colonization of legionella spp. in dental unit waterlines. Clinical protocol with digital cad/cam chairside workflow for the rehabilitation of severely worn dentition patients. Correlations between dental malocclusions, ocular motility, and convergence disorders: a cross-sectional study in growing subjects. Obstructive site localization in patients with Obstructive Sleep Apnea Syndrome: a comparison between otolaryngologic data and cephalometric values. Prosthetic management of patients with oro-maxillo-facial defects: a long-term follow-up retrospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1