{"title":"A simplified lung ultrasound approach to detect increased extravascular lung water in critically ill patients.","authors":"Antonio Anile,&nbsp;Jole Russo,&nbsp;Giacomo Castiglione,&nbsp;Giovanni Volpicelli","doi":"10.1186/s13089-017-0068-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The quantification of B-lines at lung ultrasonography is a valid tool to estimate the extravascular lung water (EVLW) in patients after major cardiac surgery. However, there is still uncertainty about the correlation between B-lines and EVLW in a general population of critically ill.</p><p><strong>Aim: </strong>To evaluate a simplified lung ultrasonographic assessment as a tool to estimate the EVLW in critically ill patients admitted to a polyvalent intensive care unit (ICU).</p><p><strong>Methods: </strong>Nineteen consecutive critically ill patients requiring mechanical ventilation and hemodynamic monitoring were enrolled. Lung ultrasonography and the thermodilution methodology (PiCCO system) were performed by two independent operators. The positive scan at lung ultrasound was defined by visualization of at least 3 B-lines. We then compared the number of chest areas positive for B-lines with the EVLW index obtained by the invasive procedure.</p><p><strong>Results: </strong>A significant correlation was found between the number of lung quadrants positive for B-lines and EVLW indexed using both actual body weight (rho = 0.612 p = 0.0053) and predicted body weight (rho = 0.493 p = 0.032). Presence of more than 3 positive lung quadrants showed a good performance in identifying an EVLW index value >10 ml/kg of actual body weight(area under the ROC 0.894; 95% CI 0.668-0.987 p < 0.0001). Presence of of more than 4 positive lung quadrants indentified an EVLW index value >10 ml/kg of predicted body weight (area under the ROC 0.8; 95% CI 0.556-0.945 p = 0.0048).</p><p><strong>Conclusion: </strong>A simplified lung ultrasound approach can by used as a reliable noninvasive bedside tool to predict EVLW in emergency and critically ill patients.</p>","PeriodicalId":46598,"journal":{"name":"Critical Ultrasound Journal","volume":null,"pages":null},"PeriodicalIF":3.6000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s13089-017-0068-x","citationCount":"41","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-017-0068-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/6/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 41

Abstract

Background: The quantification of B-lines at lung ultrasonography is a valid tool to estimate the extravascular lung water (EVLW) in patients after major cardiac surgery. However, there is still uncertainty about the correlation between B-lines and EVLW in a general population of critically ill.

Aim: To evaluate a simplified lung ultrasonographic assessment as a tool to estimate the EVLW in critically ill patients admitted to a polyvalent intensive care unit (ICU).

Methods: Nineteen consecutive critically ill patients requiring mechanical ventilation and hemodynamic monitoring were enrolled. Lung ultrasonography and the thermodilution methodology (PiCCO system) were performed by two independent operators. The positive scan at lung ultrasound was defined by visualization of at least 3 B-lines. We then compared the number of chest areas positive for B-lines with the EVLW index obtained by the invasive procedure.

Results: A significant correlation was found between the number of lung quadrants positive for B-lines and EVLW indexed using both actual body weight (rho = 0.612 p = 0.0053) and predicted body weight (rho = 0.493 p = 0.032). Presence of more than 3 positive lung quadrants showed a good performance in identifying an EVLW index value >10 ml/kg of actual body weight(area under the ROC 0.894; 95% CI 0.668-0.987 p < 0.0001). Presence of of more than 4 positive lung quadrants indentified an EVLW index value >10 ml/kg of predicted body weight (area under the ROC 0.8; 95% CI 0.556-0.945 p = 0.0048).

Conclusion: A simplified lung ultrasound approach can by used as a reliable noninvasive bedside tool to predict EVLW in emergency and critically ill patients.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种简化的肺超声方法检测危重患者血管外肺水增加。
背景:肺超声b线定量是评估心脏大手术后患者血管外肺水(EVLW)的有效工具。然而,在一般重症人群中,b系与EVLW之间的相关性仍然存在不确定性。目的:探讨简化肺超声评估作为评估多价重症监护病房(ICU)危重患者EVLW的工具。方法:连续19例需要机械通气和血流动力学监测的危重患者。肺超声检查和热稀释法(PiCCO系统)由两名独立的操作员进行。肺超声的阳性扫描通过至少3条b线的可视化来定义。然后,我们将b线阳性的胸部区域数量与侵入性手术获得的EVLW指数进行比较。结果:b系阳性肺象限数与以实际体重(rho = 0.612 p = 0.0053)和预测体重(rho = 0.493 p = 0.032)为指标的EVLW之间存在显著相关性。3个以上阳性肺象限的存在对EVLW指数值>10 ml/kg实际体重(ROC下面积0.894;95% CI 0.668-0.987 p 10 ml/kg预测体重(ROC下面积0.8;95% CI 0.556-0.945 p = 0.0048)。结论:简化肺部超声检查可作为一种可靠的无创床边工具,用于预测急危重症患者的EVLW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Critical Ultrasound Journal
Critical Ultrasound Journal RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
0.00%
发文量
0
审稿时长
13 weeks
期刊最新文献
Point-of-care ultrasound evaluation and puncture simulation of the internal jugular vein by medical students. Interpretation errors in focused cardiac ultrasound by novice pediatric emergency medicine fellow sonologists. Mitral valve velocity time integral and passive leg raise as a measure of volume responsiveness. Diagnostic performance of abdominal point of care ultrasound performed by an emergency physician in acute right iliac fossa pain. Strain analysis for the identification of hypertensive cardiac end-organ damage in the emergency department.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1