Finger Tapping Test for Assessing the Risk of Mild Cognitive Impairment.

Shota Suzumura, Aiko Osawa, Yoshikiyo Kanada, Maeda Keisuke, Eiko Takano, Junpei Sugioka, Maeda Natsumi, Taishi Nagahama, Kenta Shiramoto, Katsumi Kuno, Shiori Kizuka, Kenji Satoh, Hiroaki Sakurai, Yuko Sano, Tomohiko Mizuguchi, Akihiko Kandori, Izumi Kondo
{"title":"Finger Tapping Test for Assessing the Risk of Mild Cognitive Impairment.","authors":"Shota Suzumura, Aiko Osawa, Yoshikiyo Kanada, Maeda Keisuke, Eiko Takano, Junpei Sugioka, Maeda Natsumi, Taishi Nagahama, Kenta Shiramoto, Katsumi Kuno, Shiori Kizuka, Kenji Satoh, Hiroaki Sakurai, Yuko Sano, Tomohiko Mizuguchi, Akihiko Kandori, Izumi Kondo","doi":"10.1177/15691861221109872","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>A testing method for early diagnosis of Mild cognitive dementia (MCI) that can be easily applied in clinical practice was investigated in this study. We examined whether MCI risk can be determined through finger movements.</p><p><strong>Methods: </strong>Between 2013 and 2020, 1097 individuals were screened. After applying propensity-score matching to adjust for variability between the groups, 173 individuals each in the mild cognitive impairment and control groups were selected. Thereafter, differences between groups in mean values of parameters extracted from finger tap movements were determined using unpaired t-test and effect size. Furthermore, area under the curve, sensitivity, and specificity were calculated from the receiver operating characteristic curve for parameters with significant difference.</p><p><strong>Results: </strong>A significant difference was observed, especially in the number of taps in the MCI group compared with that in the control group (<i>p</i> < .001; 95% CI, -12.7 to -8.8; <i>r</i> = 0.51). A cut-off value of 30 taps was applied (sensitivity, 0.77; specificity, 0.67; AUC, 0.79). Significant differences were also observed in rhythm-related parameters.</p><p><strong>Conclusions: </strong>These parameters might be useful for capturing MCI risk. Finger taps are easily measured and may be suitable for screening large populations. This tool might be used as a supplemental method to increase the sensitivity of traditional cognitive tests.</p>","PeriodicalId":73249,"journal":{"name":"Hong Kong journal of occupational therapy : HKJOT","volume":"35 2","pages":"137-145"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/11/1f/10.1177_15691861221109872.PMC9716461.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hong Kong journal of occupational therapy : HKJOT","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15691861221109872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: A testing method for early diagnosis of Mild cognitive dementia (MCI) that can be easily applied in clinical practice was investigated in this study. We examined whether MCI risk can be determined through finger movements.

Methods: Between 2013 and 2020, 1097 individuals were screened. After applying propensity-score matching to adjust for variability between the groups, 173 individuals each in the mild cognitive impairment and control groups were selected. Thereafter, differences between groups in mean values of parameters extracted from finger tap movements were determined using unpaired t-test and effect size. Furthermore, area under the curve, sensitivity, and specificity were calculated from the receiver operating characteristic curve for parameters with significant difference.

Results: A significant difference was observed, especially in the number of taps in the MCI group compared with that in the control group (p < .001; 95% CI, -12.7 to -8.8; r = 0.51). A cut-off value of 30 taps was applied (sensitivity, 0.77; specificity, 0.67; AUC, 0.79). Significant differences were also observed in rhythm-related parameters.

Conclusions: These parameters might be useful for capturing MCI risk. Finger taps are easily measured and may be suitable for screening large populations. This tool might be used as a supplemental method to increase the sensitivity of traditional cognitive tests.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于评估轻度认知障碍风险的手指敲击测试。
目的:本研究探讨了一种易于应用于临床实践的早期诊断轻度认知痴呆(MCI)的测试方法。我们研究了是否可以通过手指运动来确定 MCI 风险:方法:2013 年至 2020 年间,我们对 1097 人进行了筛查。采用倾向分数匹配法调整组间差异后,轻度认知障碍组和对照组各选出 173 人。随后,采用非配对 t 检验和效应大小法确定了各组间从手指敲击运动中提取的参数平均值的差异。此外,还根据接收者操作特征曲线计算了有显著差异的参数的曲线下面积、灵敏度和特异性:与对照组相比,MCI 组的拍击次数有明显差异(P < .001;95% CI,-12.7 至 -8.8;r = 0.51)。以 30 次为临界值(灵敏度为 0.77;特异性为 0.67;AUC 为 0.79)。在节律相关参数中也观察到了显著差异:这些参数可能有助于捕捉 MCI 风险。手指敲击法易于测量,可能适用于大量人群的筛查。该工具可作为一种补充方法,提高传统认知测试的灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Re-designing the experience of transition into nursing homes: A Singapore study. Reliability and validity of five balance assessments battery in individuals with schizophrenia. Psychological and physiological benefits of horticultural therapy for Chinese older adults. Classification of life satisfaction by occupational gaps and its characteristics among older adults with care needs. Advancing readiness for change in substance use for people with substance use disorders using the Kawa model based intervention program: A quasi-experimental study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1