Assessment of Physicochemical and Microbiological Quality of Public Swimming Pools in Addis Ababa, Ethiopia.

Q3 Immunology and Microbiology Open Microbiology Journal Pub Date : 2017-06-21 eCollection Date: 2017-01-01 DOI:10.2174/1874285801711010098
Kokebe Yedeme, Melese Hailu Legese, Almaz Gonfa, Somson Girma
{"title":"Assessment of Physicochemical and Microbiological Quality of Public Swimming Pools in Addis Ababa, Ethiopia.","authors":"Kokebe Yedeme,&nbsp;Melese Hailu Legese,&nbsp;Almaz Gonfa,&nbsp;Somson Girma","doi":"10.2174/1874285801711010098","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>From swimming pools, bathers may acquire many potential pathogens or may be affected by the physicochemical characteristics of water used during bathing. Hence, this study aimed at assessing the physicochemical and microbiological quality of public swimming pools located at different hotels and recreation center in Addis Ababa, Ethiopia.</p><p><strong>Method: </strong>A cross sectional study was carried out from February to May, 2016. Nine hotels and one recreation center which recognized to have public swimming services were included. A total of 60 swimming pool water samples from 10 swimming pools were collected at deeper, shallow and intake point twice on a weekly basis using a 250 ml sterile bottle containing sodium thiosulphate. PH, residual chlorine and temperature of samples were recorded at the time of collection. Sample containing bottles were transported in ice box to microbiological laboratory and analyzed on the same day. Standard cultural and biochemical methods were used for isolation and characterization of the main microbial groups. Total viable count, total coliform count, fecal coliform count and <i>E. coli</i> were determined. Data was analyzed using SPSS Version 20.</p><p><strong>Results: </strong>Average PH and temperature of swimming pool water samples were 7.1 and 29<sup>o</sup>C respectively. Of all analyzed water samples, 58.4% (n=35/60) of them had PH range of 7.2-7.8, 58.3% (n=35/60) of samples had temperature in the range of 21<sup>o</sup>C-32<sup>o</sup>C and 25% (n=15/60) of water samples had residual chlorine in the range of 2-3mg/l. 73.3% (n=44/60) of the samples had a total viable count below 200 MPN/ml and 70% (n-42/60) of the samples had Total Coliform Count values less than 2 MPN/100 ml. Moreover, 66.7% (n=40/60) of the samples had fecal coliform counts falling below 1 MPN /100 ml. <i>E. coli</i> was absent in 70% (n=42/60) of the samples while it was present in 30% (n=18/60) of the samples.</p><p><strong>Conclusion: </strong>PH, residual chlorine and temperature value of majority of the swimming pools' water samples were within the acceptable limit. Regarding microbial quality, most swimming pools' water samples complied to the WHO standard. Swimming pools that did not comply to the standard both in physicochemical levels and microbial quality need improvement due to their significant health implication.</p>","PeriodicalId":38953,"journal":{"name":"Open Microbiology Journal","volume":"11 ","pages":"98-104"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874285801711010098","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Microbiology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874285801711010098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Immunology and Microbiology","Score":null,"Total":0}
引用次数: 15

Abstract

Background: From swimming pools, bathers may acquire many potential pathogens or may be affected by the physicochemical characteristics of water used during bathing. Hence, this study aimed at assessing the physicochemical and microbiological quality of public swimming pools located at different hotels and recreation center in Addis Ababa, Ethiopia.

Method: A cross sectional study was carried out from February to May, 2016. Nine hotels and one recreation center which recognized to have public swimming services were included. A total of 60 swimming pool water samples from 10 swimming pools were collected at deeper, shallow and intake point twice on a weekly basis using a 250 ml sterile bottle containing sodium thiosulphate. PH, residual chlorine and temperature of samples were recorded at the time of collection. Sample containing bottles were transported in ice box to microbiological laboratory and analyzed on the same day. Standard cultural and biochemical methods were used for isolation and characterization of the main microbial groups. Total viable count, total coliform count, fecal coliform count and E. coli were determined. Data was analyzed using SPSS Version 20.

Results: Average PH and temperature of swimming pool water samples were 7.1 and 29oC respectively. Of all analyzed water samples, 58.4% (n=35/60) of them had PH range of 7.2-7.8, 58.3% (n=35/60) of samples had temperature in the range of 21oC-32oC and 25% (n=15/60) of water samples had residual chlorine in the range of 2-3mg/l. 73.3% (n=44/60) of the samples had a total viable count below 200 MPN/ml and 70% (n-42/60) of the samples had Total Coliform Count values less than 2 MPN/100 ml. Moreover, 66.7% (n=40/60) of the samples had fecal coliform counts falling below 1 MPN /100 ml. E. coli was absent in 70% (n=42/60) of the samples while it was present in 30% (n=18/60) of the samples.

Conclusion: PH, residual chlorine and temperature value of majority of the swimming pools' water samples were within the acceptable limit. Regarding microbial quality, most swimming pools' water samples complied to the WHO standard. Swimming pools that did not comply to the standard both in physicochemical levels and microbial quality need improvement due to their significant health implication.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
埃塞俄比亚亚的斯亚贝巴公共游泳池理化和微生物质量评价。
背景:从游泳池中,游泳者可能获得许多潜在的病原体或可能受到洗澡时所用水的物理化学特性的影响。因此,本研究旨在评估位于埃塞俄比亚亚的斯亚贝巴不同酒店和娱乐中心的公共游泳池的理化和微生物质量。方法:于2016年2 - 5月进行横断面研究。其中包括九家酒店和一个娱乐中心,这些酒店和娱乐中心被公认为提供公共游泳服务。采用含硫代硫酸钠的250 ml无菌瓶,每周两次在较深、较浅和取水点采集60个游泳池水样。采集时记录样品的PH、余氯和温度。装瓶的样品用冰柜运输至微生物实验室,当天进行分析。采用标准培养和生化方法对主要微生物群进行分离和鉴定。测定总活菌数、总大肠菌群数、粪便大肠菌群数和大肠杆菌数。数据分析使用SPSS Version 20。结果:游泳池水样的平均PH值为7.1℃,平均温度为29℃。在所有分析的水样中,58.4% (n=35/60)的PH值在7.2 ~ 7.8之间,58.3% (n=35/60)的水样温度在21℃~ 32℃之间,25% (n=15/60)的水样余氯在2 ~ 3mg/l之间。73.3% (n=44/60)的样品总活菌数低于200 MPN/ml, 70% (n-42/60)的样品总大肠菌群计数低于2 MPN/100 ml, 66.7% (n=40/60)的样品粪便大肠菌群计数低于1 MPN/100 ml, 70% (n=42/60)的样品中没有大肠杆菌,30% (n=18/60)的样品中存在大肠杆菌。结论:大部分游泳馆水样PH、余氯、温度值均在可接受范围内。在微生物质量方面,大部分游泳池水样符合世界卫生组织标准。物理化学水平和微生物质量均不符合标准的游泳池需要改进,因为它们对健康有重大影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Open Microbiology Journal
Open Microbiology Journal Immunology and Microbiology-Immunology and Microbiology (all)
CiteScore
1.80
自引率
0.00%
发文量
24
期刊介绍: The Open Microbiology Journal is a peer-reviewed open access journal which publishes research articles, reviews/mini-reviews, case studies, guest edited thematic issues and short communications/letters covering theoretical and practical aspects of Microbial systematics, evolutionary microbiology, immunology, virology, parasitology , bacteriology, mycology, phycology, protozoology, microbial ecology, molecular biology, microbial physiology, biochemistry, microbial pathogenesis, host-microbe interaction, systems microbiology, synthetic microbiology, bioinformatics. The Open Microbiology Journal , a peer-reviewed journal, is an important and reliable source of current information on developments in the field. The emphasis will be on publishing quality papers rapidly and freely available to researchers worldwide.
期刊最新文献
Variations in Bacteriological and Physicochemical Water Quality Characteristics of Asata River, Enugu, Nigeria Molecular Detection of Chicken Anemia Virus from Chickens in Yobe South, Nigeria Isolation of Bacterial Diversity in Oil Mill Water Using Ribosomal Genes Based Fingerprinting from Morocco Characterization of Enterotoxins Produced by Food Isolates of Staphylococcus aureus Optimization of Extracellular Polysaccharide Substances from Lactic Acid Bacteria Isolated from Fermented Dairy Products
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1