Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique.

IF 2 Q3 RESPIRATORY SYSTEM Pulmonary Medicine Pub Date : 2017-01-01 Epub Date: 2017-11-16 DOI:10.1155/2017/1495867
Mark Jeremy Sanders
{"title":"Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique.","authors":"Mark Jeremy Sanders","doi":"10.1155/2017/1495867","DOIUrl":null,"url":null,"abstract":"<p><p>Portable inhalers are divisible into those that deliver medication by patient triggering (pMDIs: a gentle slow inhalation) and those that use the patient's inspiratory effort as the force for deaggregation and delivery (DPIs: a stronger deeper inspiratory effort). Patient confusion and poor technique are commonplace. The use of training tools has become standard practice, and unique amongst these is an inspiratory flow meter (In-Check) which is able to simulate the resistance characteristics of different inhalers and, thereby, guide the patient to the correct effort. In-Check's origins lie in the 1960s peak <i>expiratory</i> flow meters, the development of the Mini-Wright peak flow meter, and inspiratory flow assessment via the nose during the 1970s-1980s. The current device (In-Check DIAL G16) is the third iteration of the original 1998 training tool, with detailed and ongoing assessments of all common inhaler resistances (including combination and breath-actuated inhaler types) summarised into resistance ranges that are preset within the device. The device works by interpolating one of six ranges with the inspiratory effort. Use of the tool has been shown to be contributory to significant improvements in asthma care and control, and it is being advocated for assessment and training in irreversible lung disease.</p>","PeriodicalId":46434,"journal":{"name":"Pulmonary Medicine","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2017/1495867","citationCount":"53","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonary Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2017/1495867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/11/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 53

Abstract

Portable inhalers are divisible into those that deliver medication by patient triggering (pMDIs: a gentle slow inhalation) and those that use the patient's inspiratory effort as the force for deaggregation and delivery (DPIs: a stronger deeper inspiratory effort). Patient confusion and poor technique are commonplace. The use of training tools has become standard practice, and unique amongst these is an inspiratory flow meter (In-Check) which is able to simulate the resistance characteristics of different inhalers and, thereby, guide the patient to the correct effort. In-Check's origins lie in the 1960s peak expiratory flow meters, the development of the Mini-Wright peak flow meter, and inspiratory flow assessment via the nose during the 1970s-1980s. The current device (In-Check DIAL G16) is the third iteration of the original 1998 training tool, with detailed and ongoing assessments of all common inhaler resistances (including combination and breath-actuated inhaler types) summarised into resistance ranges that are preset within the device. The device works by interpolating one of six ranges with the inspiratory effort. Use of the tool has been shown to be contributory to significant improvements in asthma care and control, and it is being advocated for assessment and training in irreversible lung disease.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
引导吸气流动:改进吸入器技术的一种工具-在检DIAL G16的开发。
便携式吸入器可分为两种,一种是通过患者触发(pmdi:温和缓慢的吸入)给药,另一种是利用患者的吸气力作为解聚和给药的力量(DPIs:更强的吸气力)。病人的困惑和糟糕的技术是司空见惯的。培训工具的使用已成为标准做法,其中独特的是吸气流量计(In-Check),它能够模拟不同吸入器的阻力特性,从而指导患者进行正确的努力。in - check起源于20世纪60年代呼气峰值流量计,Mini-Wright峰值流量计的发展,以及20世纪70 - 80年代通过鼻子进行吸气流量评估。目前的设备(In-Check DIAL G16)是1998年原始培训工具的第三次迭代,对所有常见吸入器阻力(包括组合和呼吸驱动吸入器类型)进行了详细和持续的评估,并将其总结为设备内预设的阻力范围。该装置的工作原理是通过吸气的力度插入六个范围中的一个。该工具的使用已被证明有助于显著改善哮喘护理和控制,并且正在提倡对不可逆肺病进行评估和培训。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pulmonary Medicine
Pulmonary Medicine RESPIRATORY SYSTEM-
CiteScore
10.20
自引率
0.00%
发文量
4
审稿时长
14 weeks
期刊最新文献
Practice Variations in the Diagnosis and Treatment of Pulmonary Embolism. The Impact of COVID-19 Pandemic on Respiratory Syncytial Virus Infection in Children. Dual-Task Performance in Individuals With Chronic Obstructive Pulmonary Disease: A Systematic Review With Meta-Analysis. Establishing the Safety and Efficacy of Bedaquiline-Containing Regimen for the Treatment of Drug-Resistant Tuberculosis: A Systematic Review and Meta-Analysis of Randomized Clinical Trials. Adherence to the ISHLT Protocol for the Referral of Patients with Idiopathic Pulmonary Fibrosis to the Transplantation Center among of Czech Centers for Interstitial Lung Diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1