{"title":"Validity of Multisensor Array for Measuring Energy Expenditure of an Activity Bout in Early Stroke Survivors.","authors":"Sharon Flora Kramer, Liam Johnson, Julie Bernhardt, Toby Cumming","doi":"10.1155/2018/9134547","DOIUrl":null,"url":null,"abstract":"<p><p><i>Introduction.</i> Stroke survivors use more energy than healthy people during activities such as walking, which has consequences for the way exercise is prescribed for stroke survivors. There is a need for wearable device that can validly measure energy expenditure (EE) of activity to inform exercise prescription early after stroke. We aimed to determine the validity and reliability of the SenseWear-Armband (SWA) to measure EE and step-counts during activity <1 month after stroke. <i>Materials and Methods.</i> EE was measured using the SWA and metabolic cart and steps-counts were measured using the SWA and direct observation. Based on walking ability, participants performed 2x six-minute walks or repeated sit-to-stands. Concurrent validity and test-retest reliability were determined by calculating intraclass and concordance correlation coefficients. <i>Results and Discussion.</i> Thirteen participants walked; nine performed sit-to-stands. Validity of the SWA measuring EE for both activities was poor (ICC/CCC < 0.40). The SWA overestimates EE during walking and underestimated EE during sit-to-stands. Test-retest agreement showed an ICC/CCC of <0.40 and >0.75 for walking and sit-to-stand, respectively. However, agreement levels changed with increasing EE levels (i.e., proportional bias). The SWA did not accurately measure step-counts. <i>Conclusion.</i> The SWA should be used with caution to measure EE of activity of mild to moderate stroke survivors <1 month after stroke.</p>","PeriodicalId":22054,"journal":{"name":"Stroke Research and Treatment","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2018-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/9134547","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stroke Research and Treatment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2018/9134547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 7
Abstract
Introduction. Stroke survivors use more energy than healthy people during activities such as walking, which has consequences for the way exercise is prescribed for stroke survivors. There is a need for wearable device that can validly measure energy expenditure (EE) of activity to inform exercise prescription early after stroke. We aimed to determine the validity and reliability of the SenseWear-Armband (SWA) to measure EE and step-counts during activity <1 month after stroke. Materials and Methods. EE was measured using the SWA and metabolic cart and steps-counts were measured using the SWA and direct observation. Based on walking ability, participants performed 2x six-minute walks or repeated sit-to-stands. Concurrent validity and test-retest reliability were determined by calculating intraclass and concordance correlation coefficients. Results and Discussion. Thirteen participants walked; nine performed sit-to-stands. Validity of the SWA measuring EE for both activities was poor (ICC/CCC < 0.40). The SWA overestimates EE during walking and underestimated EE during sit-to-stands. Test-retest agreement showed an ICC/CCC of <0.40 and >0.75 for walking and sit-to-stand, respectively. However, agreement levels changed with increasing EE levels (i.e., proportional bias). The SWA did not accurately measure step-counts. Conclusion. The SWA should be used with caution to measure EE of activity of mild to moderate stroke survivors <1 month after stroke.