Ali Bourgi, Rana Aoun, Elias Ayoub, Maroun Moukarzel
{"title":"Experience with Renal Autotransplantation: Typical and Atypical Indications.","authors":"Ali Bourgi, Rana Aoun, Elias Ayoub, Maroun Moukarzel","doi":"10.1155/2018/3404587","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>Renal autotransplantation is a kidney-saving surgical procedure used in selected patients. The purpose of this report is to review nine typical and atypical indications for kidney autotransplantation and evaluate its effectiveness in maintaining kidney function and avoiding cancer recurrence.</p><p><strong>Materials and methods: </strong>From 1999 till 2014, nine renal autotransplantations were performed in our center. A retrospective case review was done. Four of nine patients had a solitary functioning kidney. Typical indications for autotransplantation included extended ureteric disease in 5 patients, intrasinusal tumor on a solitary kidney in 1 patient, and renal artery aneurysm in 1 patient. Atypical indications consisted in bilateral urothelial tumors in 1 patient and interrupted live kidney transplantation in 1 patient. Mean cold ischemia time was 209 minutes. Demographic factors, indications, renal function before and after surgery, and in the long term, cancer recurrence and disease-free survival were evaluated.</p><p><strong>Results: </strong>Renal function was maintained in 8 patients during the early follow-up. No serious complications occurred in the postoperative period. Median duration of follow-up was 50 months. In 4 patients with a normal contralateral kidney, mean preoperative and at discharge creatinine clearance were 105.45 ml/min and 121.02 ml/min, respectively. Although values showed an improvement in the kidney function, the difference was not significant (<i>p</i> value 0.3). In the other 4 patients with a solitary kidney, mean discharge creatinine clearance was 99.24 ml/min surprisingly higher than the preoperative value 96.92 ml/min. At the last follow-up, kidney function was preserved for the two groups (normal contralateral kidney/solitary kidney) with relatively stable creatinine clearance values: 108.45 ml/min and 85.9 ml/min, respectively. No patients required secondary dialysis.</p><p><strong>Conclusion: </strong>Renal autotransplantation is a rare, safe, and effective surgical procedure for the treatment of complex urologic conditions. In some instances, it may be of great utility for kidney salvage in some carefully selected patients.</p>","PeriodicalId":7490,"journal":{"name":"Advances in Urology","volume":"2018 ","pages":"3404587"},"PeriodicalIF":1.8000,"publicationDate":"2018-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/3404587","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2018/3404587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 12
Abstract
Introduction and objectives: Renal autotransplantation is a kidney-saving surgical procedure used in selected patients. The purpose of this report is to review nine typical and atypical indications for kidney autotransplantation and evaluate its effectiveness in maintaining kidney function and avoiding cancer recurrence.
Materials and methods: From 1999 till 2014, nine renal autotransplantations were performed in our center. A retrospective case review was done. Four of nine patients had a solitary functioning kidney. Typical indications for autotransplantation included extended ureteric disease in 5 patients, intrasinusal tumor on a solitary kidney in 1 patient, and renal artery aneurysm in 1 patient. Atypical indications consisted in bilateral urothelial tumors in 1 patient and interrupted live kidney transplantation in 1 patient. Mean cold ischemia time was 209 minutes. Demographic factors, indications, renal function before and after surgery, and in the long term, cancer recurrence and disease-free survival were evaluated.
Results: Renal function was maintained in 8 patients during the early follow-up. No serious complications occurred in the postoperative period. Median duration of follow-up was 50 months. In 4 patients with a normal contralateral kidney, mean preoperative and at discharge creatinine clearance were 105.45 ml/min and 121.02 ml/min, respectively. Although values showed an improvement in the kidney function, the difference was not significant (p value 0.3). In the other 4 patients with a solitary kidney, mean discharge creatinine clearance was 99.24 ml/min surprisingly higher than the preoperative value 96.92 ml/min. At the last follow-up, kidney function was preserved for the two groups (normal contralateral kidney/solitary kidney) with relatively stable creatinine clearance values: 108.45 ml/min and 85.9 ml/min, respectively. No patients required secondary dialysis.
Conclusion: Renal autotransplantation is a rare, safe, and effective surgical procedure for the treatment of complex urologic conditions. In some instances, it may be of great utility for kidney salvage in some carefully selected patients.
期刊介绍:
Advances in Urology is a peer-reviewed, open access journal that publishes state-of-the-art reviews and original research papers of wide interest in all fields of urology. The journal strives to provide publication of important manuscripts to the widest possible audience worldwide, without the constraints of expensive, hard-to-access, traditional bound journals. Advances in Urology is designed to improve publication access of both well-established urologic scientists and less well-established writers, by allowing interested scientists worldwide to participate fully.