Bone Volume Dynamics and Implant Placement Torque in Horizontal Bone Defects Reconstructed with Autologous or Xenogeneic Block Bone: A Randomized, Controlled, Split-Mouth, Prospective Clinical Trial.
Rafael Guimarães Lima, Tito Guimarães Lima, Carlos Eduardo Francischone, Cecilia Turssi, Neuza Maria Souza Picorelli Assis, Bruno Salles Sotto-Maior
{"title":"Bone Volume Dynamics and Implant Placement Torque in Horizontal Bone Defects Reconstructed with Autologous or Xenogeneic Block Bone: A Randomized, Controlled, Split-Mouth, Prospective Clinical Trial.","authors":"Rafael Guimarães Lima, Tito Guimarães Lima, Carlos Eduardo Francischone, Cecilia Turssi, Neuza Maria Souza Picorelli Assis, Bruno Salles Sotto-Maior","doi":"10.11607/jomi.6288","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate volumetric stability of autologous and xenogeneic block grafts and primary stability of implants in maxillary grafted areas.</p><p><strong>Materials and methods: </strong>Each patient received one autologous block and xenogeneic block, both covered with a membrane. Bone thickness measurements clinically and tomographically were made before, immediately, and 6 months postoperatively. After 6 months, identical implants were placed in each grafted area, and primary stability was measured.</p><p><strong>Results: </strong>Eight patients with anterior horizontal bone defects were selected. Clinical outcomes at 6 months postgrafting in the autologous block revealed a mean thickness of 7.4 ± 1.6 mm, with an initial mean measurement of 3.4 ± 1.7 mm and 2.6% resorption, whereas the mean in the xenogeneic block was 8.9 ± 1.5 mm, 3.3 ± 1.6 mm, and 7.3%, respectively. Tomographic evaluation of the thickness at 6 months postgrafting in the autologous block was a mean 7.8 ± 1.8 mm, with an initial mean of 3.7 ± 1.6 mm and resorption of 0%, while the mean in the xenogeneic block was 9.3 ± 1.6 mm, 3.6 ± 1.4 mm, and 2.1%, respectively. No significant difference in bone thickness was observed immediately or 6 months after the procedure. The mean implant placement torque was 32 ± 22 Ncm in the autologous block and 18 ± 9 Ncm in the xenogeneic block (P = .004).</p><p><strong>Conclusion: </strong>Xenogeneic block was shown to be a suitable alternative to reconstruct horizontal defects in the alveolar ridge that had undergone extensive resorption, though lower insertion torques were obtained during implant placement.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"33 4","pages":"888-894"},"PeriodicalIF":1.7000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.6288","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The aim of this study was to evaluate volumetric stability of autologous and xenogeneic block grafts and primary stability of implants in maxillary grafted areas.
Materials and methods: Each patient received one autologous block and xenogeneic block, both covered with a membrane. Bone thickness measurements clinically and tomographically were made before, immediately, and 6 months postoperatively. After 6 months, identical implants were placed in each grafted area, and primary stability was measured.
Results: Eight patients with anterior horizontal bone defects were selected. Clinical outcomes at 6 months postgrafting in the autologous block revealed a mean thickness of 7.4 ± 1.6 mm, with an initial mean measurement of 3.4 ± 1.7 mm and 2.6% resorption, whereas the mean in the xenogeneic block was 8.9 ± 1.5 mm, 3.3 ± 1.6 mm, and 7.3%, respectively. Tomographic evaluation of the thickness at 6 months postgrafting in the autologous block was a mean 7.8 ± 1.8 mm, with an initial mean of 3.7 ± 1.6 mm and resorption of 0%, while the mean in the xenogeneic block was 9.3 ± 1.6 mm, 3.6 ± 1.4 mm, and 2.1%, respectively. No significant difference in bone thickness was observed immediately or 6 months after the procedure. The mean implant placement torque was 32 ± 22 Ncm in the autologous block and 18 ± 9 Ncm in the xenogeneic block (P = .004).
Conclusion: Xenogeneic block was shown to be a suitable alternative to reconstruct horizontal defects in the alveolar ridge that had undergone extensive resorption, though lower insertion torques were obtained during implant placement.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.