Performance analysis of automated evaluation of antinuclear antibody indirect immunofluorescent tests in a routine setting.

Q1 Medicine Auto-Immunity Highlights Pub Date : 2018-09-21 DOI:10.1007/s13317-018-0108-y
Joyce J B C van Beers, Melanie Hahn, Johanna Fraune, Kathleen Mallet, Christopher Krause, Wymke Hormann, Kai Fechner, Jan G M C Damoiseaux
{"title":"Performance analysis of automated evaluation of antinuclear antibody indirect immunofluorescent tests in a routine setting.","authors":"Joyce J B C van Beers,&nbsp;Melanie Hahn,&nbsp;Johanna Fraune,&nbsp;Kathleen Mallet,&nbsp;Christopher Krause,&nbsp;Wymke Hormann,&nbsp;Kai Fechner,&nbsp;Jan G M C Damoiseaux","doi":"10.1007/s13317-018-0108-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Indirect immunofluorescence (IIF) on the human epithelial cell-line HEp-2 (or derivatives) serves as the gold standard in antinuclear antibody (ANA) screening. IIF, and its evaluation, is a labor-intensive method, making ANA testing a major challenge for present clinical laboratories. Nowadays, several automated ANA pattern recognition systems are on the market. In the current study, the EUROPattern Suite is evaluated for its use in daily practice in a routine setting.</p><p><strong>Methods: </strong>A total of 1033 consecutive routine samples was used to screen for ANA. Results (positive/negative ANA screening, pattern identification and titer) were compared between software-generated results (EUROPattern) and visual interpretation (observer) of automatically acquired digital images.</p><p><strong>Results: </strong>Considering the visual interpretation as reference, a relative sensitivity of 99.3% and a relative specificity of 88.9% were obtained for negative and positive discrimination by the software (EPa). A good agreement between visual and software-based interpretation was observed with respect to pattern recognition (mean kappa: for 7 patterns: 0.7). Interestingly, EPa software distinguished more patterns per positive sample than the observer (on average 1.5 and 1.2, respectively). Finally, a concordance of 99.3% was observed within the range of 1 titer step difference between EPa and observer.</p><p><strong>Conclusions: </strong>The ANA IIF results reported by the EPa software are in very good agreement with the results reported by the observer with respect to being negative/positive, pattern recognition and titer, making automated ANA IIF evaluation an objective and time-efficient tool for routine testing.</p>","PeriodicalId":8655,"journal":{"name":"Auto-Immunity Highlights","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s13317-018-0108-y","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Auto-Immunity Highlights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13317-018-0108-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 10

Abstract

Purpose: Indirect immunofluorescence (IIF) on the human epithelial cell-line HEp-2 (or derivatives) serves as the gold standard in antinuclear antibody (ANA) screening. IIF, and its evaluation, is a labor-intensive method, making ANA testing a major challenge for present clinical laboratories. Nowadays, several automated ANA pattern recognition systems are on the market. In the current study, the EUROPattern Suite is evaluated for its use in daily practice in a routine setting.

Methods: A total of 1033 consecutive routine samples was used to screen for ANA. Results (positive/negative ANA screening, pattern identification and titer) were compared between software-generated results (EUROPattern) and visual interpretation (observer) of automatically acquired digital images.

Results: Considering the visual interpretation as reference, a relative sensitivity of 99.3% and a relative specificity of 88.9% were obtained for negative and positive discrimination by the software (EPa). A good agreement between visual and software-based interpretation was observed with respect to pattern recognition (mean kappa: for 7 patterns: 0.7). Interestingly, EPa software distinguished more patterns per positive sample than the observer (on average 1.5 and 1.2, respectively). Finally, a concordance of 99.3% was observed within the range of 1 titer step difference between EPa and observer.

Conclusions: The ANA IIF results reported by the EPa software are in very good agreement with the results reported by the observer with respect to being negative/positive, pattern recognition and titer, making automated ANA IIF evaluation an objective and time-efficient tool for routine testing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
常规设置中抗核抗体间接免疫荧光试验自动评价的性能分析。
目的:对人上皮细胞系HEp-2(或其衍生物)进行间接免疫荧光(IIF)检测可作为筛选抗核抗体(ANA)的金标准。IIF及其评估是一种劳动密集型方法,使ANA检测成为当前临床实验室的主要挑战。目前,市场上出现了几种自动的ANA模式识别系统。在目前的研究中,评估EUROPattern套件在日常实践中的使用情况。方法:采用1033例常规标本进行ANA筛查。将软件生成的结果(EUROPattern)与自动获取的数字图像的视觉判读(观察者)进行比较(ANA阳性/阴性筛选、模式识别和滴度)。结果:以目测判读为参照,EPa软件对阴性和阳性判读的相对灵敏度为99.3%,相对特异性为88.9%。在模式识别方面,观察到视觉和基于软件的解释之间有很好的一致性(7种模式的平均kappa: 0.7)。有趣的是,EPa软件比观察者区分出每个阳性样本更多的模式(平均分别为1.5和1.2)。最后,EPa与观察者在1个滴度级差范围内的一致性达到99.3%。结论:EPa软件报告的ANA IIF结果与观察者报告的结果在阴性/阳性、模式识别和滴度方面非常一致,使自动化ANA IIF评估成为常规检测的客观和省时的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Potential clinical biomarkers in rheumatoid arthritis with an omic approach. Effect of janus kinase inhibitors and methotrexate combination on malignancy in patients with rheumatoid arthritis: a systematic review and meta-analysis of randomized controlled trials. Short-chain fatty acids and intestinal inflammation in multiple sclerosis: modulation of female susceptibility by microbial products? Endogenous mitochondrial double-stranded RNA is not an activator of the type I interferon response in human pancreatic beta cells. Sustained clinical remission under infliximab/rituximab combination therapy in a patient with granulomatosis with polyangiitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1