Safety and Feasibility of Balloon-Assisted Embolization with Onyx of Brain Arteriovenous Malformations Revisited: Personal Experience with the Scepter XC Balloon Microcatheter.

Q1 Medicine Interventional Neurology Pub Date : 2018-10-01 Epub Date: 2018-07-13 DOI:10.1159/000490579
Bharathi D Jagadeesan, Andrew W Grande, Ramachandra P Tummala
{"title":"Safety and Feasibility of Balloon-Assisted Embolization with Onyx of Brain Arteriovenous Malformations Revisited: Personal Experience with the Scepter XC Balloon Microcatheter.","authors":"Bharathi D Jagadeesan,&nbsp;Andrew W Grande,&nbsp;Ramachandra P Tummala","doi":"10.1159/000490579","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objective: </strong>Compliant dual-lumen balloon microcatheters have been used to perform balloon-assisted embolization (BAE) of brain arteriovenous malformations (AVMs) with ethylene vinyl alcohol copolymer (Onyx). However, vessel rupture and microcatheter retention have been reported from BAE using these microcatheters. Using an extra-compliant balloon microcatheter (Scepter XC; Microvention, Tustin, CA, USA) could help avoid pial vessel rupture during BAE. We herein report our experience using this balloon microcatheter for BAE.</p><p><strong>Methods: </strong>This retrospective study included patients who underwent BAE of brain AVMs at our institution between June 2012 and March 2017.</p><p><strong>Results: </strong>The extra-compliant Scepter XC balloon microcatheter was used for BAE of brain AVMs in 23 patients aged 44.3 ± 16.7 years (range 0-65 years). A total of 40 intracranial vessels (39 pial arteries and 1 pial vein) were catheterized and embolized during 30 separate sessions. In all instances, the balloon microcatheter could be successfully advanced to the AVM nidus. A mean volume of 2.4 ± 1.7 mL (range 0.65-4.6 mL) of Onyx was injected per session. There were no instances of vessel rupture, microcatheter retention, or stroke.</p><p><strong>Conclusion: </strong>Utilization of the extra-compliant balloon microcatheter results in safe and effective BAE, which adds to the growing experience with BAE for AVM treatment.</p>","PeriodicalId":46280,"journal":{"name":"Interventional Neurology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000490579","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000490579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/7/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 12

Abstract

Background/objective: Compliant dual-lumen balloon microcatheters have been used to perform balloon-assisted embolization (BAE) of brain arteriovenous malformations (AVMs) with ethylene vinyl alcohol copolymer (Onyx). However, vessel rupture and microcatheter retention have been reported from BAE using these microcatheters. Using an extra-compliant balloon microcatheter (Scepter XC; Microvention, Tustin, CA, USA) could help avoid pial vessel rupture during BAE. We herein report our experience using this balloon microcatheter for BAE.

Methods: This retrospective study included patients who underwent BAE of brain AVMs at our institution between June 2012 and March 2017.

Results: The extra-compliant Scepter XC balloon microcatheter was used for BAE of brain AVMs in 23 patients aged 44.3 ± 16.7 years (range 0-65 years). A total of 40 intracranial vessels (39 pial arteries and 1 pial vein) were catheterized and embolized during 30 separate sessions. In all instances, the balloon microcatheter could be successfully advanced to the AVM nidus. A mean volume of 2.4 ± 1.7 mL (range 0.65-4.6 mL) of Onyx was injected per session. There were no instances of vessel rupture, microcatheter retention, or stroke.

Conclusion: Utilization of the extra-compliant balloon microcatheter results in safe and effective BAE, which adds to the growing experience with BAE for AVM treatment.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
再谈球囊辅助脑动静脉畸形栓塞术的安全性和可行性:使用Scepter XC球囊微导管的个人经验。
背景/目的:柔性双腔球囊微导管已被用于乙烯乙烯醇共聚物(Onyx)脑动静脉畸形(AVMs)的球囊辅助栓塞(BAE)。然而,在使用这些微导管的BAE中,有血管破裂和微导管潴留的报道。使用超柔顺球囊微导管(Scepter XC;Microvention, Tustin, CA, USA)可以帮助避免BAE中颅底血管破裂。我们在此报告使用球囊微导管治疗BAE的经验。方法:本回顾性研究纳入2012年6月至2017年3月在我院接受脑动静脉畸形BAE治疗的患者。结果:采用超顺性Scepter XC球囊微导管治疗脑AVMs患者23例,年龄44.3±16.7岁(0 ~ 65岁)。共40条颅内血管(39条颅底动脉和1条颅底静脉)在30个单独的疗程中插管和栓塞。在所有病例中,球囊微导管均可成功推进至AVM病灶。每次注射平均2.4±1.7 mL (0.65-4.6 mL)的Onyx。没有血管破裂、微导管滞留或中风的病例。结论:超顺性球囊微导管的应用安全有效,增加了BAE治疗AVM的经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neurology
Interventional Neurology CLINICAL NEUROLOGY-
自引率
0.00%
发文量
0
期刊最新文献
Recanalization of Tandem Vertebrobasilar Occlusions with Contralateral Vertebral Occlusion or Hypoplasia via either Direct Passage or the SHERPA Technique. Does the Addition of Non-Approved Inclusion and Exclusion Criteria for rtPA Impact Treatment Rates? Findings in Australia, the UK, and the USA. In vitro Remote Aspiration Embolectomy for the Treatment of Acute Ischemic Stroke. Endovascular Reperfusion for Acute Isolated Cervical Carotid Occlusions: The Concept of "Hemodynamic Thrombectomy". An Appraisal of the 2018 Guidelines for the Early Management of Patients with Acute Ischemic Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1