{"title":"Experimental study on the detection of cerebral hemorrhage in rabbits based on broadband antenna technology.","authors":"Haisheng Zhang, Mingsheng Chen, Gui Jin, Jia Xu, Mingxin Qin","doi":"10.1080/24699322.2018.1557893","DOIUrl":null,"url":null,"abstract":"<p><p>Hematoma enlargement often occurs in patients with spontaneous intracerebral hemorrhage (ICH), so it is necessary to monitor the amount of intracranial hemorrhage in patients after admission. At present, the commonly used intracranial pressure (ICP) method has the disadvantages of trauma and infection, and the Computer Tomography (CT) method cannot achieve continuous monitoring. So it is urgent to develop a non-contact and non-invasive method for continuous monitoring of cerebral hemorrhage. The dielectric properties of blood are different from those of brain tissue, so the hematoma will affect the amplitude and phase of the electromagnetic waves passing through the head. A microstrip antenna was designed to construct the detection system for cerebral hemorrhage. Based on the animal model of acute cerebral hemorrhage, the detecting experiment was carried out on thirteen rabbits. Each rabbit had three bleeding states: 1, 2, and 3 ml, which represented the severity of cerebral hemorrhage. According to the measured data of high dimension and small sample, the support vector machine (SVM) algorithm was used to assess the severity of cerebral hemorrhage. According to simulation results, the antenna's forward radiation was 5 dB larger than the backward radiation, which ensured the antenna being not affected by external signals during the measurement. According to test results, the -10 dB workband of the antenna was 1.55-2.05 GHz and the frequency range of the transmission parameters <i>S</i><sub>21</sub> above -30 dB is 1.2 - 3 GHz. In the animal experiment, the phase difference of Transmission coefficient <i>S</i><sub>21</sub> was gradually increased with the increase of bleeding volume. Through the classification of 39 bleeding states of the 13 rabbits, the total accuracy was about 77%. Through animal experiments, the feasibility of detection method has been proved. But the classification accuracy need to be further improved. The detection system is based on broadband antenna has the potential to realize non-contact, non-invasive and continuous monitoring for cerebral hemorrhage.</p>","PeriodicalId":56051,"journal":{"name":"Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/24699322.2018.1557893","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/24699322.2018.1557893","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 7
Abstract
Hematoma enlargement often occurs in patients with spontaneous intracerebral hemorrhage (ICH), so it is necessary to monitor the amount of intracranial hemorrhage in patients after admission. At present, the commonly used intracranial pressure (ICP) method has the disadvantages of trauma and infection, and the Computer Tomography (CT) method cannot achieve continuous monitoring. So it is urgent to develop a non-contact and non-invasive method for continuous monitoring of cerebral hemorrhage. The dielectric properties of blood are different from those of brain tissue, so the hematoma will affect the amplitude and phase of the electromagnetic waves passing through the head. A microstrip antenna was designed to construct the detection system for cerebral hemorrhage. Based on the animal model of acute cerebral hemorrhage, the detecting experiment was carried out on thirteen rabbits. Each rabbit had three bleeding states: 1, 2, and 3 ml, which represented the severity of cerebral hemorrhage. According to the measured data of high dimension and small sample, the support vector machine (SVM) algorithm was used to assess the severity of cerebral hemorrhage. According to simulation results, the antenna's forward radiation was 5 dB larger than the backward radiation, which ensured the antenna being not affected by external signals during the measurement. According to test results, the -10 dB workband of the antenna was 1.55-2.05 GHz and the frequency range of the transmission parameters S21 above -30 dB is 1.2 - 3 GHz. In the animal experiment, the phase difference of Transmission coefficient S21 was gradually increased with the increase of bleeding volume. Through the classification of 39 bleeding states of the 13 rabbits, the total accuracy was about 77%. Through animal experiments, the feasibility of detection method has been proved. But the classification accuracy need to be further improved. The detection system is based on broadband antenna has the potential to realize non-contact, non-invasive and continuous monitoring for cerebral hemorrhage.
期刊介绍:
omputer Assisted Surgery aims to improve patient care by advancing the utilization of computers during treatment; to evaluate the benefits and risks associated with the integration of advanced digital technologies into surgical practice; to disseminate clinical and basic research relevant to stereotactic surgery, minimal access surgery, endoscopy, and surgical robotics; to encourage interdisciplinary collaboration between engineers and physicians in developing new concepts and applications; to educate clinicians about the principles and techniques of computer assisted surgery and therapeutics; and to serve the international scientific community as a medium for the transfer of new information relating to theory, research, and practice in biomedical imaging and the surgical specialties.
The scope of Computer Assisted Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotactic procedures, surgery guided by intraoperative ultrasound or magnetic resonance imaging, image guided focused irradiation, robotic surgery, and any therapeutic interventions performed with the use of digital imaging technology.