Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test-retest reliability.

Pub Date : 2019-06-01 Epub Date: 2018-10-15 DOI:10.1142/S1013702519500069
Daniel Simpson, Monika Ehrensberger, Christopher Nulty, Joanne Regan, Patrick Broderick, Catherine Blake, Kenneth Monaghan
{"title":"Peak torque, rate of torque development and average torque of isometric ankle and elbow contractions show excellent test-retest reliability.","authors":"Daniel Simpson,&nbsp;Monika Ehrensberger,&nbsp;Christopher Nulty,&nbsp;Joanne Regan,&nbsp;Patrick Broderick,&nbsp;Catherine Blake,&nbsp;Kenneth Monaghan","doi":"10.1142/S1013702519500069","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Peak Torque (PT), Rate of Torque Development (RTD) and Average Torque (AT) over a single contraction assess the three components of muscle function during isometric contractions. Surprisingly, AT has never been reported or its reliability confirmed.</p><p><strong>Objectives: </strong>This study aims to establish protocol reliability for ankle dorsiflexion and elbow extension isometric muscle function (PT, RTD, AT) in healthy participants using the Biodex System 3 Dynamometer.</p><p><strong>Methods: </strong>Twelve participants (6 male, 6 female, mean age <math><mn>39</mn> <mo>.</mo> <mn>8</mn> <mo>±</mo> <mn>16</mn> <mo>.</mo> <mn>0</mn></math> years) performed four maximal isometric contractions on two occasions. Intraclass Correlation Coefficient (ICC), Typical Error (TE) and Coefficient of Variation (CV) for PT, RTD and AT were reported.</p><p><strong>Results: </strong>The ICC for all strength parameters varied from 0.98-0.92. TE for ankle dorsiflexion PT was 1.38 Nm, RTD 7.43 Nm/s and AT 1.33 Nm, CV varied from <math><mn>6</mn> <mo>.</mo> <mn>26</mn> <mo>±</mo> <mn>6</mn> <mo>.</mo> <mn>25</mn> <mi>%</mi></math> to <math><mn>11</mn> <mo>.</mo> <mn>72</mn> <mo>±</mo> <mn>8</mn> <mo>.</mo> <mn>27</mn> <mi>%</mi></math> . For elbow extension, TE was 3.36 Nm for PT, 14.87 Nm/s for RTD and 3.03 Nm for AT, CV varied from <math><mn>5</mn> <mo>.</mo> <mn>97</mn> <mo>±</mo> <mn>4</mn> <mo>.</mo> <mn>52</mn> <mi>%</mi></math> to <math><mn>18</mn> <mo>.</mo> <mn>46</mn> <mo>±</mo> <mn>14</mn> <mo>.</mo> <mn>78</mn> <mi>%</mi></math> .</p><p><strong>Conclusion: </strong>Maximal isometric ankle dorsiflexion and elbow extension PT, RTD and AT can be evaluated with excellent reliability when following the described protocol. This testing procedure, including the application of AT, can be confidently applied in research, exercise or clinical settings.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1142/S1013702519500069","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/S1013702519500069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/10/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background: Peak Torque (PT), Rate of Torque Development (RTD) and Average Torque (AT) over a single contraction assess the three components of muscle function during isometric contractions. Surprisingly, AT has never been reported or its reliability confirmed.

Objectives: This study aims to establish protocol reliability for ankle dorsiflexion and elbow extension isometric muscle function (PT, RTD, AT) in healthy participants using the Biodex System 3 Dynamometer.

Methods: Twelve participants (6 male, 6 female, mean age 39 . 8 ± 16 . 0 years) performed four maximal isometric contractions on two occasions. Intraclass Correlation Coefficient (ICC), Typical Error (TE) and Coefficient of Variation (CV) for PT, RTD and AT were reported.

Results: The ICC for all strength parameters varied from 0.98-0.92. TE for ankle dorsiflexion PT was 1.38 Nm, RTD 7.43 Nm/s and AT 1.33 Nm, CV varied from 6 . 26 ± 6 . 25 % to 11 . 72 ± 8 . 27 % . For elbow extension, TE was 3.36 Nm for PT, 14.87 Nm/s for RTD and 3.03 Nm for AT, CV varied from 5 . 97 ± 4 . 52 % to 18 . 46 ± 14 . 78 % .

Conclusion: Maximal isometric ankle dorsiflexion and elbow extension PT, RTD and AT can be evaluated with excellent reliability when following the described protocol. This testing procedure, including the application of AT, can be confidently applied in research, exercise or clinical settings.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
踝关节和肘关节等距收缩的峰值扭矩、扭矩发展速率和平均扭矩表现出良好的重测可靠性。
背景:单次收缩的峰值扭矩(PT),扭矩发展率(RTD)和平均扭矩(AT)评估等长收缩期间肌肉功能的三个组成部分。令人惊讶的是,AT从未被报道过,其可靠性也从未得到证实。目的:本研究旨在利用Biodex System 3测功仪建立健康参与者踝关节背屈和肘关节伸等长肌肉功能(PT, RTD, AT)的方案可靠性。方法:12例受试者,男6例,女6例,平均年龄39岁。8±16。0岁)两次进行了4次最大等距收缩。报道了PT、RTD和AT的类内相关系数(ICC)、典型误差(TE)和变异系数(CV)。结果:各强度参数的ICC值在0.98 ~ 0.92之间。踝关节背屈PT的TE为1.38 Nm, RTD为7.43 Nm/s, AT为1.33 Nm, CV为6。26±6。25%对11%。72±8。27%。肘关节伸展时,PT组TE值为3.36 Nm, RTD组为14.87 Nm/s, AT组为3.03 Nm/s, CV值为5。97±4。52%对18%。46±14。结论:最大等距踝关节背屈度和肘关节伸度的PT、RTD和AT在遵循上述方案时可获得极高的可靠性。这种测试程序,包括AT的应用,可以自信地应用于研究、锻炼或临床环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1