{"title":"Development of wearable posture monitoring system for dynamic assessment of sitting posture.","authors":"Chi-Chih Wu, Chuang-Chien Chiu, Chun-Yu Yeh","doi":"10.1007/s13246-019-00836-4","DOIUrl":null,"url":null,"abstract":"<p><p>There have been increasing cases of people seeking treatment for neck and back pain. The most common cause of neck and back pain is due to long-term poor sitting posture. The most common poor sitting posture cases are humpback, and head and neck being too far forward. It is easy to cause neck and back pain and other symptoms. Therefore, the development of wearable posture monitoring system for dynamic assessment of sitting posture becomes both helpful and necessary. In addition to recording the wearer's posture when sitting with quantitative assessment, it is needed to execute real-time action feedback for correctness of posture, in order to reduce neck and back pain due to long-term poor sitting posture. This study completed an instant recording and dynamic assessment of position measurement and feedback system. The system consists of a number of dynamic measurement units that can describe the posture trajectory, which integrates three-axis gyro meter, three-axis accelerometer, and magnetometer in order to measure the dynamic tracking. In the reliability analysis experiment, angle measurement error is less than 2%. The correlation coefficient between correlation analysis and Motion Analysis (MA) is 0.97. It is shown that the motion trajectory of this system is highly correlated with MA. In the feasibility test of sitting position detection, it is possible to detect the sitting position from the basic action of the walking, standing, sitting and lying down, and the sensitivity reaches 95.84%. In the assessment of the sitting position, the information published by the Canadian Centre for Occupational Health and Safety was used, as well as the recommendations of professional physicians as a basis for evaluating the threshold of the sitting measurement parameters and immediately feedback to the subjects. The system developed in this study can be helpful to reduce neck and back pain due to long-term poor sitting posture.</p>","PeriodicalId":55430,"journal":{"name":"Australasian Physical & Engineering Sciences in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Physical & Engineering Sciences in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s13246-019-00836-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
Abstract
There have been increasing cases of people seeking treatment for neck and back pain. The most common cause of neck and back pain is due to long-term poor sitting posture. The most common poor sitting posture cases are humpback, and head and neck being too far forward. It is easy to cause neck and back pain and other symptoms. Therefore, the development of wearable posture monitoring system for dynamic assessment of sitting posture becomes both helpful and necessary. In addition to recording the wearer's posture when sitting with quantitative assessment, it is needed to execute real-time action feedback for correctness of posture, in order to reduce neck and back pain due to long-term poor sitting posture. This study completed an instant recording and dynamic assessment of position measurement and feedback system. The system consists of a number of dynamic measurement units that can describe the posture trajectory, which integrates three-axis gyro meter, three-axis accelerometer, and magnetometer in order to measure the dynamic tracking. In the reliability analysis experiment, angle measurement error is less than 2%. The correlation coefficient between correlation analysis and Motion Analysis (MA) is 0.97. It is shown that the motion trajectory of this system is highly correlated with MA. In the feasibility test of sitting position detection, it is possible to detect the sitting position from the basic action of the walking, standing, sitting and lying down, and the sensitivity reaches 95.84%. In the assessment of the sitting position, the information published by the Canadian Centre for Occupational Health and Safety was used, as well as the recommendations of professional physicians as a basis for evaluating the threshold of the sitting measurement parameters and immediately feedback to the subjects. The system developed in this study can be helpful to reduce neck and back pain due to long-term poor sitting posture.
期刊介绍:
Australasian Physical & Engineering Sciences in Medicine (APESM) is a multidisciplinary forum for information and research on the application of physics and engineering to medicine and human physiology. APESM covers a broad range of topics that include but is not limited to:
- Medical physics in radiotherapy
- Medical physics in diagnostic radiology
- Medical physics in nuclear medicine
- Mathematical modelling applied to medicine and human biology
- Clinical biomedical engineering
- Feature extraction, classification of EEG, ECG, EMG, EOG, and other biomedical signals;
- Medical imaging - contributions to new and improved methods;
- Modelling of physiological systems
- Image processing to extract information from images, e.g. fMRI, CT, etc.;
- Biomechanics, especially with applications to orthopaedics.
- Nanotechnology in medicine
APESM offers original reviews, scientific papers, scientific notes, technical papers, educational notes, book reviews and letters to the editor.
APESM is the journal of the Australasian College of Physical Scientists and Engineers in Medicine, and also the official journal of the College of Biomedical Engineers, Engineers Australia and the Asia-Oceania Federation of Organizations for Medical Physics.