{"title":"Investigations on Contamination of Environmental Water Samples by Legionella using Real-Time Quantitative PCR Combined with Amoebic Co-Culturing.","authors":"Akiko Edagawa, Akio Kimura, Hiroshi Miyamoto","doi":"10.4265/bio.24.213","DOIUrl":null,"url":null,"abstract":"<p><p>We analyzed the contamination of environmental water samples with Legionella spp. using a conventional culture method, real-time quantitative PCR (qPCR), and real-time qPCR combined with an amoebic co-culture method. Samples (n = 110) were collected from 19 cooling towers, 31 amenity water facilities, and 60 river water sources of tap water in Japan. Legionella was detected in only three samples (3/110, 2.7%) using the culture method. The rate of Legionella detection using amoebic co-culture followed by qPCR was 74.5%, while that using qPCR without amoebic co-culture was 75.5%. A higher than 10-fold bacterial count was observed in 19 samples (19/110, 17.3%) using real-time qPCR subsequent to amoebic co-culture, compared with identical samples analyzed without co-culture. Of these 19 samples, 13 were identified as Legionella spp., including L. pneumophila and L. anisa, and the non-culturable species were identified as L. lytica and L. rowbothamii. This study showed that the detection of Legionella spp., even in those samples where they were not detected by the culture method, was possible using real-time qPCR and an amoebic co-culture method. In addition, this analytical test combination is a useful tool to detect viable and virulent Legionella spp..</p>","PeriodicalId":8777,"journal":{"name":"Biocontrol science","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4265/bio.24.213","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocontrol science","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.4265/bio.24.213","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 6
Abstract
We analyzed the contamination of environmental water samples with Legionella spp. using a conventional culture method, real-time quantitative PCR (qPCR), and real-time qPCR combined with an amoebic co-culture method. Samples (n = 110) were collected from 19 cooling towers, 31 amenity water facilities, and 60 river water sources of tap water in Japan. Legionella was detected in only three samples (3/110, 2.7%) using the culture method. The rate of Legionella detection using amoebic co-culture followed by qPCR was 74.5%, while that using qPCR without amoebic co-culture was 75.5%. A higher than 10-fold bacterial count was observed in 19 samples (19/110, 17.3%) using real-time qPCR subsequent to amoebic co-culture, compared with identical samples analyzed without co-culture. Of these 19 samples, 13 were identified as Legionella spp., including L. pneumophila and L. anisa, and the non-culturable species were identified as L. lytica and L. rowbothamii. This study showed that the detection of Legionella spp., even in those samples where they were not detected by the culture method, was possible using real-time qPCR and an amoebic co-culture method. In addition, this analytical test combination is a useful tool to detect viable and virulent Legionella spp..
期刊介绍:
The Biocontrol Science provides a medium for the publication of original articles, concise notes, and review articles on all aspects of science and technology of biocontrol.