Impact of new techniques on adenoma detection rate based on meta-analysis data.

Ci ji yi xue za zhi = Tzu-chi medical journal Pub Date : 2019-11-20 eCollection Date: 2020-04-01 DOI:10.4103/tcmj.tcmj_148_19
Chih-Wei Tseng, Felix W Leung, Yu-Hsi Hsieha
{"title":"Impact of new techniques on adenoma detection rate based on meta-analysis data.","authors":"Chih-Wei Tseng, Felix W Leung, Yu-Hsi Hsieha","doi":"10.4103/tcmj.tcmj_148_19","DOIUrl":null,"url":null,"abstract":"<p><p>The high incidence of colorectal cancer and the occurrence of interval cancers after screening colonoscopy support the need to develop methods to increase adenoma detection rate (ADR). This review focuses on the importance of ADR and the impact of new techniques on ADR based on meta-analysis data. The low-cost interventions (such as water-aided colonoscopy, second observation, and dynamic position change) were effective in increasing ADR. So were enhanced imaging techniques and add-on devices. Increase with higher cost interventions such as newer scopes is uncertain. Water exchange (WE) has the highest ADR compared with water immersion, air insufflation, and carbon dioxide insufflation. Second observation with forward or retroflexed views improved the right colon ADR. Add-on devices result in only modest improvement in ADR, of particular help in low performing endoscopists. The second-generation narrow-band imaging (NBI) provided a two-fold brighter image than the previous system. The improvement in ADR with NBI required the \"best\" quality bowel preparation. New endoscopic techniques incur various additional costs, nil for WE, small for tip attachments but large for the newer scopes. In conclusion, one or more of the above methods to improve ADR may be applicable in Taiwan. A comparison of these approaches to determine which is the most cost-effective is warranted.</p>","PeriodicalId":72593,"journal":{"name":"Ci ji yi xue za zhi = Tzu-chi medical journal","volume":"32 2","pages":"131-136"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d3/ed/TCMJ-32-131.PMC7137362.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ci ji yi xue za zhi = Tzu-chi medical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/tcmj.tcmj_148_19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/4/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The high incidence of colorectal cancer and the occurrence of interval cancers after screening colonoscopy support the need to develop methods to increase adenoma detection rate (ADR). This review focuses on the importance of ADR and the impact of new techniques on ADR based on meta-analysis data. The low-cost interventions (such as water-aided colonoscopy, second observation, and dynamic position change) were effective in increasing ADR. So were enhanced imaging techniques and add-on devices. Increase with higher cost interventions such as newer scopes is uncertain. Water exchange (WE) has the highest ADR compared with water immersion, air insufflation, and carbon dioxide insufflation. Second observation with forward or retroflexed views improved the right colon ADR. Add-on devices result in only modest improvement in ADR, of particular help in low performing endoscopists. The second-generation narrow-band imaging (NBI) provided a two-fold brighter image than the previous system. The improvement in ADR with NBI required the "best" quality bowel preparation. New endoscopic techniques incur various additional costs, nil for WE, small for tip attachments but large for the newer scopes. In conclusion, one or more of the above methods to improve ADR may be applicable in Taiwan. A comparison of these approaches to determine which is the most cost-effective is warranted.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于荟萃分析数据的新技术对腺瘤检出率的影响。
结肠直肠癌的高发病率和结肠镜筛查后间歇性癌症的发生支持了开发提高腺瘤检出率(ADR)方法的必要性。本综述基于荟萃分析数据,重点探讨 ADR 的重要性以及新技术对 ADR 的影响。低成本干预措施(如水辅助结肠镜检查、二次观察和动态体位改变)可有效提高 ADR。增强型成像技术和附加装置也是如此。成本较高的干预措施(如较新的探头)能否增加 ADR 还不确定。与水浸泡、空气充气和二氧化碳充气相比,水交换(WE)的 ADR 最高。通过前视或后视进行二次观察可改善右结肠 ADR。附加设备只能适度改善 ADR,尤其是对工作效率低的内镜医师有帮助。第二代窄带成像(NBI)的图像亮度是前代系统的两倍。NBI 对 ADR 的改善需要 "最佳 "质量的肠道准备。新的内窥镜技术会产生各种额外费用,WE 的费用为零,尖端附件的费用较低,但较新的探头的费用较高。总之,上述一种或多种改善 ADR 的方法可能适用于台湾。有必要对这些方法进行比较,以确定哪种方法最具成本效益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dancing pharynx. Prevalence and correlates of antenatal depression among women registered at antenatal clinic in North India. Targeting of interleukin-10 receptor by a potential human interleukin-10 peptide efficiently blocks interleukin-10 pathway-dependent cell proliferation. Association of bone mineral density and trabecular bone score with cardiovascular disease. Is there a role for oxidative stress and mitochondrial dysfunction in age-associated bladder disorders?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1