Critical Assessment of Single-Use Ureteroscopes in an In Vivo Porcine Model.

IF 1.8 Q3 UROLOGY & NEPHROLOGY Advances in Urology Pub Date : 2020-04-27 eCollection Date: 2020-01-01 DOI:10.1155/2020/3842680
Brian Ceballos, Charles U Nottingham, Seth K Bechis, Roger L Sur, Brian R Matlaga, Amy E Krambeck
{"title":"Critical Assessment of Single-Use Ureteroscopes in an <i>In Vivo</i> Porcine Model.","authors":"Brian Ceballos,&nbsp;Charles U Nottingham,&nbsp;Seth K Bechis,&nbsp;Roger L Sur,&nbsp;Brian R Matlaga,&nbsp;Amy E Krambeck","doi":"10.1155/2020/3842680","DOIUrl":null,"url":null,"abstract":"<p><strong>Methods: </strong>A female pig was placed under general anesthesia and positioned supine, and retrograde access to the renal collecting system was obtained. The LithoVue (Boston Scientific) and Uscope (Pusen Medical) were evaluated by three experienced surgeons, and each surgeon started with a new scope. The following parameters were compared between each ureteroscope: time for navigation to upper and lower pole calyces with and without implements (1.9 F basket, 200 <i>μ</i>m laser fiber, and 365 <i>μ</i>m laser fiber for upper only) in the working channel and subjective evaluations of maneuverability, irrigant flow through the scope, lever force, ergonomics, and scope optics.</p><p><strong>Results: </strong>Navigation to the lower pole calyx was significantly faster with LithoVue compared to Uscope when the working channel was empty (24.3 vs. 49.4 seconds, <i>p</i> < 0.01) and with a 200 <i>μ</i>m fiber (63.6 vs. 94.4 seconds, <i>p</i>=0.04), but not with the 1.9 F basket. Navigation to the upper pole calyx was similar for all categories except faster with LithoVue containing the 365 <i>μ</i>m fiber (67.1 vs. 99.7 seconds, <i>p</i>=0.02). Subjective assessments of scope maneuverability to upper and lower pole calyces when the scope was empty and with implements favored LithoVue in all categories, as did assessments of irrigant flow, illumination, image quality, and field of view. Both scopes had similar scores of lever force and ergonomics.</p><p><strong>Conclusions: </strong>In an <i>in vivo</i> porcine model, the type of single-use ureteroscope employed affected the navigation times and subjective assessments of maneuverability and visualization. In all cases, LithoVue provided either equivalent or superior metrics than Uscope. Further clinical studies are necessary to determine the implications of these findings.</p>","PeriodicalId":7490,"journal":{"name":"Advances in Urology","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2020-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2020/3842680","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2020/3842680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 4

Abstract

Methods: A female pig was placed under general anesthesia and positioned supine, and retrograde access to the renal collecting system was obtained. The LithoVue (Boston Scientific) and Uscope (Pusen Medical) were evaluated by three experienced surgeons, and each surgeon started with a new scope. The following parameters were compared between each ureteroscope: time for navigation to upper and lower pole calyces with and without implements (1.9 F basket, 200 μm laser fiber, and 365 μm laser fiber for upper only) in the working channel and subjective evaluations of maneuverability, irrigant flow through the scope, lever force, ergonomics, and scope optics.

Results: Navigation to the lower pole calyx was significantly faster with LithoVue compared to Uscope when the working channel was empty (24.3 vs. 49.4 seconds, p < 0.01) and with a 200 μm fiber (63.6 vs. 94.4 seconds, p=0.04), but not with the 1.9 F basket. Navigation to the upper pole calyx was similar for all categories except faster with LithoVue containing the 365 μm fiber (67.1 vs. 99.7 seconds, p=0.02). Subjective assessments of scope maneuverability to upper and lower pole calyces when the scope was empty and with implements favored LithoVue in all categories, as did assessments of irrigant flow, illumination, image quality, and field of view. Both scopes had similar scores of lever force and ergonomics.

Conclusions: In an in vivo porcine model, the type of single-use ureteroscope employed affected the navigation times and subjective assessments of maneuverability and visualization. In all cases, LithoVue provided either equivalent or superior metrics than Uscope. Further clinical studies are necessary to determine the implications of these findings.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一次性输尿管镜在猪体内模型中的关键评估。
方法:母猪全身麻醉,仰卧位,逆行进入肾收集系统。LithoVue (Boston Scientific)和Uscope (Pusen Medical)由三位经验丰富的外科医生进行评估,每位外科医生开始使用新的内镜。比较各输尿管镜的以下参数:工作通道内带和不带工具(1.9 F筐、200 μm激光光纤和仅上端365 μm激光光纤)到上、下极肾盏的时间、可操作性主观评价、镜内灌液流量、杠杆力、工效学和镜内光学性能。结果:与Uscope相比,当工作通道为空(24.3 vs 49.4秒,p < 0.01)和200 μm纤维(63.6 vs 94.4秒,p=0.04)时,LithoVue导航到下极花萼的速度明显快于Uscope,但使用1.9 F篮时则没有。除了含有365 μm纤维的LithoVue更快(67.1秒对99.7秒,p=0.02)之外,所有类别的导航到上极花萼都相似。当瞄准镜是空的并且使用工具时,对上下极萼的瞄准镜可操作性的主观评估在所有类别中都有利于LithoVue,对灌溉流量、照明、图像质量和视野的评估也是如此。两种瞄准镜在杠杆力和人体工程学方面得分相似。结论:在猪体内模型中,使用的一次性输尿管镜类型影响了导航次数和可操作性和可视化的主观评价。在所有情况下,LithoVue都提供了与Uscope相当或更好的指标。需要进一步的临床研究来确定这些发现的意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Urology
Advances in Urology UROLOGY & NEPHROLOGY-
CiteScore
2.90
自引率
0.00%
发文量
17
审稿时长
15 weeks
期刊介绍: Advances in Urology is a peer-reviewed, open access journal that publishes state-of-the-art reviews and original research papers of wide interest in all fields of urology. The journal strives to provide publication of important manuscripts to the widest possible audience worldwide, without the constraints of expensive, hard-to-access, traditional bound journals. Advances in Urology is designed to improve publication access of both well-established urologic scientists and less well-established writers, by allowing interested scientists worldwide to participate fully.
期刊最新文献
A Review of Electronic Early Warning Systems for Acute Kidney Injury. Patient Demographics and Major Adverse Cardiovascular Events after Androgen Deprivation Therapy for Prostate Cancer. Complications and Influential Perioperative Factors Associated with SpaceOAR Hydrogel Placement. Photodynamic Therapeutic Effect during 5-Aminolevulinic Acid-Mediated Photodynamic Diagnosis-Assisted Transurethral Resection of Bladder Tumors. Effects of the Surgical Ligation of the Ureter in Different Locations on the Kidney over Time in the Rat Model.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1