Hemodynamic Performance of Pericardial Bioprostheses in the Aortic Position.

Haeju Lee, Ho Young Hwang, Suk Ho Sohn, Jae Woong Choi, Jun-Bean Park, Kyung Hwan Kim, Ki-Bong Kim
{"title":"Hemodynamic Performance of Pericardial Bioprostheses in the Aortic Position.","authors":"Haeju Lee,&nbsp;Ho Young Hwang,&nbsp;Suk Ho Sohn,&nbsp;Jae Woong Choi,&nbsp;Jun-Bean Park,&nbsp;Kyung Hwan Kim,&nbsp;Ki-Bong Kim","doi":"10.5090/kjtcs.19.099","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study was conducted to evaluate the hemodynamic performance and the incidence of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) using bovine pericardial valves (Carpentier-Edwards Perimount Magana and Magna Ease).</p><p><strong>Methods: </strong>In total, 216 patients (mean age, 70.0±10.5 years) who underwent AVR using stented bovine pericardial valves and had follow-up echocardiography between 3 months and 2 years (mean, 12.0±6.6 months) after surgery were enrolled. The implanted valve sizes were 19, 21, 23, and 25 mm in 32, 56, 99, and 29 patients, respectively.</p><p><strong>Results: </strong>On follow-up echocardiography, the mean transvalvular pressure gradients for the 19-mm, 21-mm, 23-mm, and 25-mm valves were 13.3±4.4, 12.6±4.2, 10.5±3.9, and 10.2± 3.7 mm Hg, respectively. The effective orifice area (EOA) was 1.25±0.26, 1.54±0.31, 1.81±0.41, and 1.87±0.33 cm2, respectively. These values were smaller than those suggested by the manufacturer for the corresponding sizes. No patients had PPM, when based on the reference EOA. However, moderate (EOA index ≤0.85 cm<sup>2</sup>/m<sup>2</sup>) and severe (EOA index ≤0.65 cm<sup>2</sup>/m<sup>2</sup>) PPM was present in 56 patients (11.8%) and 9 patients (1.9%), respectively, when using the measured values.</p><p><strong>Conclusion: </strong>Carpentier-Edwards Perimount Magna and Magna Ease bovine pericardial valves showed satisfactory hemodynamic performance with low rates of PPM, although the reference EOA could overestimate the true EOA for individual patients.</p>","PeriodicalId":38678,"journal":{"name":"Korean Journal of Thoracic and Cardiovascular Surgery","volume":"53 5","pages":"285-290"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/96/1e/KJTCV-53-285.PMC7553830.pdf","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Thoracic and Cardiovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5090/kjtcs.19.099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4

Abstract

Background: This study was conducted to evaluate the hemodynamic performance and the incidence of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) using bovine pericardial valves (Carpentier-Edwards Perimount Magana and Magna Ease).

Methods: In total, 216 patients (mean age, 70.0±10.5 years) who underwent AVR using stented bovine pericardial valves and had follow-up echocardiography between 3 months and 2 years (mean, 12.0±6.6 months) after surgery were enrolled. The implanted valve sizes were 19, 21, 23, and 25 mm in 32, 56, 99, and 29 patients, respectively.

Results: On follow-up echocardiography, the mean transvalvular pressure gradients for the 19-mm, 21-mm, 23-mm, and 25-mm valves were 13.3±4.4, 12.6±4.2, 10.5±3.9, and 10.2± 3.7 mm Hg, respectively. The effective orifice area (EOA) was 1.25±0.26, 1.54±0.31, 1.81±0.41, and 1.87±0.33 cm2, respectively. These values were smaller than those suggested by the manufacturer for the corresponding sizes. No patients had PPM, when based on the reference EOA. However, moderate (EOA index ≤0.85 cm2/m2) and severe (EOA index ≤0.65 cm2/m2) PPM was present in 56 patients (11.8%) and 9 patients (1.9%), respectively, when using the measured values.

Conclusion: Carpentier-Edwards Perimount Magna and Magna Ease bovine pericardial valves showed satisfactory hemodynamic performance with low rates of PPM, although the reference EOA could overestimate the true EOA for individual patients.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
主动脉位置心包生物假体的血流动力学性能。
背景:本研究旨在评估牛心包瓣膜(Carpentier-Edwards Perimount Magana和Magna Ease)主动脉瓣置换术(AVR)后的血流动力学性能和假体-患者不匹配(PPM)的发生率。方法:共216例(平均年龄70.0±10.5岁)采用支架牛心包瓣膜行AVR,术后3个月至2年(平均12.0±6.6个月)超声心动图随访。32例,56例,99例,29例,植入瓣膜大小分别为19、21、23、25 mm。结果:在随访的超声心动图中,19、21、23、25 mm瓣膜的平均经瓣压力梯度分别为13.3±4.4、12.6±4.2、10.5±3.9和10.2±3.7 mm Hg。有效孔面积(EOA)分别为1.25±0.26、1.54±0.31、1.81±0.41和1.87±0.33 cm2。这些值小于制造商对相应尺寸的建议值。根据参考EOA,没有患者出现PPM。然而,当使用测量值时,中度(EOA指数≤0.85 cm2/m2)和重度(EOA指数≤0.65 cm2/m2) PPM分别存在56例(11.8%)和9例(1.9%)。结论:Carpentier-Edwards Perimount Magna和Magna Ease牛心包瓣膜在低PPM率下表现出令人满意的血流动力学性能,尽管参考EOA可能高估个别患者的真实EOA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
36 weeks
期刊最新文献
Thoracomyoplasty for Chronic Empyema and Osteoradionecrosis of the Chest Wall Levoatrial Cardinal Vein: Occluder Embolization and Complication Management Quadriplegia after Mitral Valve Replacement in an Infective Endocarditis Patient with Cervical Spine Spondylitis Eighteen Years of Follow-up after Resection of a Giant Coronary Artery Aneurysm and Reconstruction with a Vein Graft A Giant Pseudo-Aneurysm on the Anastomosis Site for a Redo Bentall Operation due to Behçet Disease Treated by Thoracic Endovascular Aortic Aneurysm Repair with a Custom-Made Stent Graft.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1