Myoelectric untethered robotic glove enhances hand function and performance on daily living tasks after stroke.

IF 2 Q3 ENGINEERING, BIOMEDICAL Journal of Rehabilitation and Assistive Technologies Engineering Pub Date : 2020-12-15 eCollection Date: 2020-01-01 DOI:10.1177/2055668320964050
Aaron Yurkewich, Illya J Kozak, Andrei Ivanovic, Daniel Rossos, Rosalie H Wang, Debbie Hebert, Alex Mihailidis
{"title":"Myoelectric untethered robotic glove enhances hand function and performance on daily living tasks after stroke.","authors":"Aaron Yurkewich,&nbsp;Illya J Kozak,&nbsp;Andrei Ivanovic,&nbsp;Daniel Rossos,&nbsp;Rosalie H Wang,&nbsp;Debbie Hebert,&nbsp;Alex Mihailidis","doi":"10.1177/2055668320964050","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Wearable robots controlled using electromyography could motivate greater use of the affected upper extremity after stroke and enable bimanual activities of daily living to be completed independently.</p><p><strong>Methods: </strong>We have developed a myoelectric untethered robotic glove (My-HERO) that provides five-finger extension and grip assistance.</p><p><strong>Results: </strong>The myoelectric controller detected the grip and release intents of the 9 participants after stroke with 84.7% accuracy. While using My-HERO, all 9 participants performed better on the Fugl-Meyer Assessment-Hand (8.4 point increase, scale out of 14, p < 0.01) and the Chedoke Arm and Hand Activity Inventory (8.2 point increase, scale out of 91, p < 0.01). Established criteria for clinically meaningful important differences were surpassed for both the hand function and daily living task assessments. The majority of participants provided satisfaction and usability questionnaire scores above 70%. Seven participants desired to use My-HERO in the clinic and at home during their therapy and daily routines.</p><p><strong>Conclusions: </strong>People with hand impairment after stroke value that myoelectric untethered robotic gloves enhance their motion and bimanual task performance and motivate them to use their muscles during engaging activities of daily living. They desire to use these gloves daily to enable greater independence and investigate the effects on neuromuscular recovery.</p>","PeriodicalId":43319,"journal":{"name":"Journal of Rehabilitation and Assistive Technologies Engineering","volume":"7 ","pages":"2055668320964050"},"PeriodicalIF":2.0000,"publicationDate":"2020-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/2055668320964050","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation and Assistive Technologies Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2055668320964050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 15

Abstract

Introduction: Wearable robots controlled using electromyography could motivate greater use of the affected upper extremity after stroke and enable bimanual activities of daily living to be completed independently.

Methods: We have developed a myoelectric untethered robotic glove (My-HERO) that provides five-finger extension and grip assistance.

Results: The myoelectric controller detected the grip and release intents of the 9 participants after stroke with 84.7% accuracy. While using My-HERO, all 9 participants performed better on the Fugl-Meyer Assessment-Hand (8.4 point increase, scale out of 14, p < 0.01) and the Chedoke Arm and Hand Activity Inventory (8.2 point increase, scale out of 91, p < 0.01). Established criteria for clinically meaningful important differences were surpassed for both the hand function and daily living task assessments. The majority of participants provided satisfaction and usability questionnaire scores above 70%. Seven participants desired to use My-HERO in the clinic and at home during their therapy and daily routines.

Conclusions: People with hand impairment after stroke value that myoelectric untethered robotic gloves enhance their motion and bimanual task performance and motivate them to use their muscles during engaging activities of daily living. They desire to use these gloves daily to enable greater independence and investigate the effects on neuromuscular recovery.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肌电无系绳机器人手套增强中风后的手部功能和日常生活任务的表现。
简介:使用肌电图控制的可穿戴机器人可以在中风后激发更多地使用受影响的上肢,并使日常生活的双手活动能够独立完成。方法:我们开发了一种肌电无系绳机器人手套(My-HERO),提供五指伸展和抓握辅助。结果:肌电控制器对9名受试者卒中后握力和释放意图的检测准确率为84.7%。在使用My-HERO时,所有9名参与者在Fugl-Meyer手部评估中表现更好(8.4分,评分为14,p)。结论:中风后手部损伤患者认为肌电无系带机器人手套增强了他们的运动和双手任务表现,并激励他们在参与日常生活活动时使用肌肉。他们希望每天使用这些手套,以获得更大的独立性,并研究对神经肌肉恢复的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
5.00%
发文量
37
期刊最新文献
Inclusive design and usability testing: Involving an end-user in developing augmentative and alternative communication user interfaces using an open-source platform. The development of a wearable goggle echolocation device to support people who are visually impaired with unhindered and unaided movement. Students perspectives on the development and deployment of an AI-enabled service robot in long-term care. Real-time evaluation of an automated computer vision system to monitor pain behavior in older adults. People with spinal cord injury or stroke are able to reach moderate-to-vigorous intensity while exercising on an end-effector robot assisted gait trainer: A pilot study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1