{"title":"In-depth investigation of turn-around time of full blood count tests requested from a clinical haematology outpatient department in Cape Town, South Africa.","authors":"Leonard Mutema, Zivanai Chapanduka, Fungai Musaigwa, Nomusa Mashigo","doi":"10.4102/ajlm.v10i1.1318","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The performance of laboratories can be objectively assessed using the overall turn-around time (TAT). However, TAT is defined differently by the laboratory and clinicians; therefore, it is important to determine the contribution of all the different components making up the laboratory test cycle.</p><p><strong>Objective: </strong>We carried out a retrospective analysis of the TAT of full blood count tests requested from the haematology outpatient department at Tygerberg Academic Hospital in Cape Town, South Africa, with an aim to assess laboratory performance and to identify critical steps influencing TAT.</p><p><strong>Methods: </strong>A retrospective audit was carried out, focused on the full blood count tests from the haematology outpatient department within a period of 3 months between 01 February and 30 April 2018. Data was extracted from the National Health Laboratory Service laboratory information system. The time intervals of all the phases of the test cycle were determined and total TAT and within-laboratory (intra-lab) TAT were calculated.</p><p><strong>Results: </strong>A total of 1176 tests were analysed. The total TAT median was 275 (interquartile range [IQR] 200.0-1537.7) min with the most prolonged phase being from authorisation to review by clinicians (median 114 min; IQR: 37.0-1338.5 min). The median intra-lab TAT was 55 (IQR 40-81) min and 90% of the samples were processed in the laboratory within 134 min of registration.</p><p><strong>Conclusion: </strong>Our findings showed that the intra-lab TAT was within the set internal benchmark of 3 h. Operational phases that were independent of the laboratory processes contributed the most to total TAT.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":"10 1","pages":"1318"},"PeriodicalIF":1.0000,"publicationDate":"2021-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8111617/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v10i1.1318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The performance of laboratories can be objectively assessed using the overall turn-around time (TAT). However, TAT is defined differently by the laboratory and clinicians; therefore, it is important to determine the contribution of all the different components making up the laboratory test cycle.

Objective: We carried out a retrospective analysis of the TAT of full blood count tests requested from the haematology outpatient department at Tygerberg Academic Hospital in Cape Town, South Africa, with an aim to assess laboratory performance and to identify critical steps influencing TAT.

Methods: A retrospective audit was carried out, focused on the full blood count tests from the haematology outpatient department within a period of 3 months between 01 February and 30 April 2018. Data was extracted from the National Health Laboratory Service laboratory information system. The time intervals of all the phases of the test cycle were determined and total TAT and within-laboratory (intra-lab) TAT were calculated.

Results: A total of 1176 tests were analysed. The total TAT median was 275 (interquartile range [IQR] 200.0-1537.7) min with the most prolonged phase being from authorisation to review by clinicians (median 114 min; IQR: 37.0-1338.5 min). The median intra-lab TAT was 55 (IQR 40-81) min and 90% of the samples were processed in the laboratory within 134 min of registration.

Conclusion: Our findings showed that the intra-lab TAT was within the set internal benchmark of 3 h. Operational phases that were independent of the laboratory processes contributed the most to total TAT.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
深入调查南非开普敦临床血液学门诊部申请全血细胞计数检验的周转时间。
背景:实验室的绩效可以通过总体周转时间(TAT)进行客观评估。然而,实验室和临床医生对 TAT 的定义各不相同;因此,确定构成实验室检验周期的所有不同组成部分的贡献非常重要:我们对南非开普敦泰格贝格学术医院(Tygerberg Academic Hospital)血液学门诊部申请的全血细胞计数检验的TAT进行了回顾性分析,目的是评估实验室绩效并确定影响TAT的关键步骤:在2018年2月1日至4月30日的3个月内,对血液学门诊部的全血细胞计数检验进行了回顾性审核。数据提取自国家卫生实验室服务实验室信息系统。确定了检验周期所有阶段的时间间隔,并计算了总TAT和实验室内(实验室内)TAT:结果:共分析了 1176 项检验。总 TAT 中位数为 275 分钟(四分位数间距 [IQR]:200.0-1537.7),从授权到临床医生审核的阶段时间最长(中位数为 114 分钟;IQR:37.0-1338.5 分钟)。实验室内 TAT 的中位数为 55(IQR 40-81)分钟,90% 的样本在登记后 134 分钟内完成实验室处理:我们的研究结果表明,实验室内的总处理时间在设定的内部基准 3 小时之内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
African Journal of Laboratory Medicine
African Journal of Laboratory Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.70
自引率
9.10%
发文量
53
审稿时长
12 weeks
期刊介绍: The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.
期刊最新文献
ESKAPE pathogen incidence and antibiotic resistance in patients with bloodstream infections at a referral hospital in Limpopo, South Africa, 2014-2019: A cross-sectional study. The scourge of antimicrobial resistance: Containing a global crisis. Pathobiology of HIV-related metabolic and cardiovascular comorbidities: Towards a unifying mechanism. An audit of the iron status of patients at Chris Hani Baragwanath Academic Hospital, in Johannesburg, South Africa. Carriers of the m.3243A>G variant should not be labelled with an acronym before they have been systematically screened for multisystem disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1