Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

IF 1.2 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING European Journal of Hybrid Imaging Pub Date : 2021-02-28 DOI:10.1186/s41824-021-00098-y
Bo Bao, Crystal S Liu, Edward C O Masson, Jonathan T Abele
{"title":"Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.","authors":"Bo Bao,&nbsp;Crystal S Liu,&nbsp;Edward C O Masson,&nbsp;Jonathan T Abele","doi":"10.1186/s41824-021-00098-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.</p><p><strong>Methods: </strong>A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard.</p><p><strong>Results: </strong>The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%).</p><p><strong>Conclusion: </strong>SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.</p>","PeriodicalId":36160,"journal":{"name":"European Journal of Hybrid Imaging","volume":"5 1","pages":"4"},"PeriodicalIF":1.2000,"publicationDate":"2021-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218161/pdf/","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Hybrid Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41824-021-00098-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 24

Abstract

Purpose: To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.

Methods: A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard.

Results: The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%).

Conclusion: SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SPECT/CT关节造影对疑似无菌性关节假体松动的诊断准确性。
目的:评价SPECT/CT关节造影对髋关节置换术后疑似无菌性假体松动的诊断准确性。方法:回顾性分析2013年2月1日至2018年7月1日期间的63例SPECT/CT关节造影研究(36例膝关节和27例髋关节)。所有患者都接受了临床和放射学评估,作为髋关节和膝关节置换术后持续疼痛评估的一部分。在SPECT/CT上沿骨-假体界面检测示踪剂活性提示无菌性松动。手术评估以及至少1年的临床/放射学随访作为参考标准。结果:SPECT/CT检测无菌性松动的敏感性为6/7(86%),特异性为55/56(98%)。阳性预测值(PPV)为6/7(86%),阴性预测值(NPV)为55/56(98%),诊断准确率为61/63(97%)。结论:SPECT/CT关节造影在评估髋关节和膝关节置换术后持续疼痛患者松动时具有很高的诊断准确性(97%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Journal of Hybrid Imaging
European Journal of Hybrid Imaging Computer Science-Computer Science (miscellaneous)
CiteScore
3.40
自引率
0.00%
发文量
29
审稿时长
17 weeks
期刊最新文献
Phosphaturic mesenchymal tumor demonstrated by 68Ga-DOTATATE PET/CT in a patient: a case report Carcinoid crisis in Lutetium-177-Dotatate therapy of neuroendocrine tumors: an overview of pathophysiology, risk factors, recognition, and treatment Four-dimensional computed tomography as first-line imaging in primary hyperparathyroidism, a retrospective comparison to conventional imaging in a predominantly single adenoma population Clinical value of semi-quantitative parameters in 68Ga-DOTANOC PET/CT in treatment and diagnostics of cranial meningioma in a single-center retrospective analysis Cardiac transplant rejection assessment with 18F-FDG PET-CT: initial single-centre experience for diagnosis and management
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1