Evaluation of 3 refractometers to determine transfer of passive immunity in neonatal beef calves.

IF 2.6 2区 农林科学 Journal of Veterinary Internal Medicine Pub Date : 2021-01-01 Epub Date: 2020-12-23 DOI:10.1111/jvim.16016
Lisa Gamsjäger, Ibrahim Elsohaby, Jennifer M Pearson, Michel Levy, Edmond A Pajor, M Claire Windeyer
{"title":"Evaluation of 3 refractometers to determine transfer of passive immunity in neonatal beef calves.","authors":"Lisa Gamsjäger,&nbsp;Ibrahim Elsohaby,&nbsp;Jennifer M Pearson,&nbsp;Michel Levy,&nbsp;Edmond A Pajor,&nbsp;M Claire Windeyer","doi":"10.1111/jvim.16016","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Refractometry is used to assess transfer of passive immunity (TPI), but studies evaluating different refractometers and appropriate thresholds for recommended target immunoglobulin G (IgG) concentrations for beef calves are limited.</p><p><strong>Objectives: </strong>To evaluate test performance of digital (DSTP) and optical (OSTP) serum total protein (STP) refractometers and a digital Brix (DBRIX) refractometer for assessment of passive immunity in beef calves.</p><p><strong>Animals: </strong>A total of 398 beef calves from 6 herds, 1 to 7 days of age.</p><p><strong>Methods: </strong>Serum IgG concentration was estimated by DSTP, OSTP, and DBRIX, and measured by radial immunodiffusion (RID). Correlation coefficients (r) among results were calculated. Optimal STP and Brix thresholds for identification of IgG <10, <16, and <24 g/L were determined using interval likelihood ratios. Refractometer performance and agreement were assessed using areas under the curve (AUC), diagnostic test characteristics, Cohen's kappa (κ), and Bland-Altman analysis.</p><p><strong>Results: </strong>Refractometer results were highly correlated with RID (r = 0.82-0.91) and with each other (r = 0.91-0.95), and overall test performance was excellent (AUC = 0.93-0.99). The STP concentrations of ≤5.1, ≤5.1, and ≤5.7 g/dL and Brix percentages of ≤7.9%, ≤8.3%, and ≤8.7% indicated IgG concentrations <10, <16, and <24 g/L, respectively. Agreement of refractometers with RID was variable (κ = 0.46-0.80) and among refractometers was substantial (κ = 0.62-0.89).</p><p><strong>Conclusions and clinical importance: </strong>All refractometers showed good utility as monitoring tools for assessment of TPI in beef calves.</p>","PeriodicalId":17462,"journal":{"name":"Journal of Veterinary Internal Medicine","volume":"35 1","pages":"632-643"},"PeriodicalIF":2.6000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/jvim.16016","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Internal Medicine","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/jvim.16016","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/12/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Background: Refractometry is used to assess transfer of passive immunity (TPI), but studies evaluating different refractometers and appropriate thresholds for recommended target immunoglobulin G (IgG) concentrations for beef calves are limited.

Objectives: To evaluate test performance of digital (DSTP) and optical (OSTP) serum total protein (STP) refractometers and a digital Brix (DBRIX) refractometer for assessment of passive immunity in beef calves.

Animals: A total of 398 beef calves from 6 herds, 1 to 7 days of age.

Methods: Serum IgG concentration was estimated by DSTP, OSTP, and DBRIX, and measured by radial immunodiffusion (RID). Correlation coefficients (r) among results were calculated. Optimal STP and Brix thresholds for identification of IgG <10, <16, and <24 g/L were determined using interval likelihood ratios. Refractometer performance and agreement were assessed using areas under the curve (AUC), diagnostic test characteristics, Cohen's kappa (κ), and Bland-Altman analysis.

Results: Refractometer results were highly correlated with RID (r = 0.82-0.91) and with each other (r = 0.91-0.95), and overall test performance was excellent (AUC = 0.93-0.99). The STP concentrations of ≤5.1, ≤5.1, and ≤5.7 g/dL and Brix percentages of ≤7.9%, ≤8.3%, and ≤8.7% indicated IgG concentrations <10, <16, and <24 g/L, respectively. Agreement of refractometers with RID was variable (κ = 0.46-0.80) and among refractometers was substantial (κ = 0.62-0.89).

Conclusions and clinical importance: All refractometers showed good utility as monitoring tools for assessment of TPI in beef calves.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3种折射仪测定新生肉牛被动免疫转移的评价。
背景:屈光仪用于评估被动免疫转移(TPI),但评估不同屈光仪和推荐靶免疫球蛋白G (IgG)浓度的适当阈值的研究有限。目的:评价数字式(DSTP)、光学式(OSTP)血清总蛋白(STP)折光仪和数字式Brix (DBRIX)折光仪在评价肉牛被动免疫中的测试性能。动物:来自6个畜群的398头1 - 7日龄肉牛。方法:采用DSTP、OSTP、DBRIX法测定血清IgG浓度,采用径向免疫扩散法(RID)测定血清IgG浓度。计算结果之间的相关系数(r)。结果:折射仪检测结果与RID高度相关(r = 0.82-0.91),与RID高度相关(r = 0.91-0.95),整体检测性能良好(AUC = 0.93-0.99)。STP浓度≤5.1、≤5.1和≤5.7 g/dL, Brix百分比≤7.9%、≤8.3%和≤8.7%表示IgG浓度。结论和临床意义:所有折射仪作为评估肉牛TPI的监测工具都具有良好的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Veterinary Internal Medicine
Journal of Veterinary Internal Medicine Veterinary-General Veterinary
自引率
11.50%
发文量
243
期刊介绍: The mission of the Journal of Veterinary Internal Medicine is to advance veterinary medical knowledge and improve the lives of animals by publication of authoritative scientific articles of animal diseases.
期刊最新文献
Dose-exposure-response of CARDALIS® (benazepril/spironolactone) on the classical and alternative arms of the renin-angiotensin-aldosterone system in healthy dogs. Predictive factors associated with short-term mortality in cats with feline infectious peritonitis treated with remdesivir or GS-441524 or both. Diagnosis of naturally-occurring Cushing's syndrome by primary care veterinarians in selected European countries. Frequency and progression of azotemia during acute and chronic treatment of congestive heart failure in cats. Salivary peptidomic profiling of chronic gingivostomatitis in cats by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry and nanoscale liquid chromatography-tandem mass spectrometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1