{"title":"Efficacy of Chest Compressions Performed on Patients in Dental Chairs Versus on the Floor.","authors":"Yoshitaka Shimizu, Takuma Sadamori, Noboru Saeki, Akari Mukai, Mitsuru Doi, Kana Oue, Mitsuhiro Yoshida, Masahiro Irifune","doi":"10.2344/anpr-68-01-07","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the characteristics of chest compressions performed in dental chairs (DCs) with 2 different structural support designs and on the floor. This randomized prospective study was conducted to compare the effectiveness of chest compressions (rate and depth) using a feedback device and a manikin reporting system. The mean anterior chest wall motion measurements captured using the feedback device were significantly increased in the DCs than on the floor, whereas the percentage of net chest compression depths ≥5 cm as measured using the manikin reporting system were significantly decreased in the DCs than on the floor. These findings suggest that cardiopulmonary resuscitation performed in a DC without the use of a supporting stool or stiff backboard is not likely to be effective even if a DC design that incorporates a supportive steel column is utilized.</p>","PeriodicalId":7818,"journal":{"name":"Anesthesia progress","volume":"68 2","pages":"85-89"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8258752/pdf/i0003-3006-68-2-85.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesia progress","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2344/anpr-68-01-07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to investigate the characteristics of chest compressions performed in dental chairs (DCs) with 2 different structural support designs and on the floor. This randomized prospective study was conducted to compare the effectiveness of chest compressions (rate and depth) using a feedback device and a manikin reporting system. The mean anterior chest wall motion measurements captured using the feedback device were significantly increased in the DCs than on the floor, whereas the percentage of net chest compression depths ≥5 cm as measured using the manikin reporting system were significantly decreased in the DCs than on the floor. These findings suggest that cardiopulmonary resuscitation performed in a DC without the use of a supporting stool or stiff backboard is not likely to be effective even if a DC design that incorporates a supportive steel column is utilized.
期刊介绍:
Anesthesia Progress is a peer-reviewed journal and the official publication of the American Dental Society of Anesthesiology. The journal is dedicated to providing a better understanding of the advances being made in the art and science of pain and anxiety control in dentistry.